Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in Newborns

Background: Delayed or missed diagnosis of critical and cyanotic congenital heart disease (CHD) in asymptomatic newborns may result in significant morbidity and mortality. The aim of this study was to determine the accuracy of pulse oximetry screening  performed on the first day of life for the earl...

Full description

Bibliographic Details
Main Authors: Amir Hosein Movahedian, Ziba Mosayebi, Setareh Sagheb
Format: Article
Language:English
Published: Tehran University of Medical Sciences 2016-10-01
Series:Journal of Tehran University Heart Center
Subjects:
Online Access:https://jthc.tums.ac.ir/index.php/jthc/article/view/583
_version_ 1811275767741415424
author Amir Hosein Movahedian
Ziba Mosayebi
Setareh Sagheb
author_facet Amir Hosein Movahedian
Ziba Mosayebi
Setareh Sagheb
author_sort Amir Hosein Movahedian
collection DOAJ
description Background: Delayed or missed diagnosis of critical and cyanotic congenital heart disease (CHD) in asymptomatic newborns may result in significant morbidity and mortality. The aim of this study was to determine the accuracy of pulse oximetry screening  performed on the first day of life for the early detection of critical and cyanotic CHD in apparently normal newborns. Methods: This cross-sectional study used postductal pulse oximetry to evaluate term neonates born between 2008 and 2011 with normal physical examinations. Functional oxygen saturation < 95% was considered abnormal, and second measurement was done 2 hours later. If the second measurement remained < 95%, an echocardiogram was performed. On enrolment in the study, the following data for each neonate were recorded: gestational age, gender, birth weight, mode of delivery, and mother’s age. Results: During the study period, totally 3,846 newborns were evaluated. Of the whole study population, 304 (7.9%) babies  had a  postductal functional saturation < 95%. The second measurement was also < 95% in 104 (2.7%) neonates. The mean age of the neonates at the time of pulse oximetry was 18.91 ± 8.61 (min = 4.5 and max = 49) hours. Forty-nine percent of the subjects were female and 51% were male. Echocardiography was performed on 81 out of 104 newborns, and 14 (0.36%) of them had CHD. The types of CHD in our patients were tetralogy of Fallot (3 cases), transposition of the great vessels (2 cases), double-outlet right ventricle (2 cases), truncus arteriosus, total anomalous pulmonary venous return, atrioventricular septal defect, pulmonary atresia, persistent pulmonary hypertension, ventricular septal defect, and atrial septal defect (1 case for each type). The best time for pulse oximetry was within 8-24 hours of the newborns’ life. Conclusion: Pulse oximetry screening along with clinical examination may be able to assist in the early detection of critical and cyanotic CHD in asymptomatic newborns.
first_indexed 2024-04-12T23:44:58Z
format Article
id doaj.art-7b23b7ba5c7c4e969cd4d62506953300
institution Directory Open Access Journal
issn 1735-8620
2008-2371
language English
last_indexed 2024-04-12T23:44:58Z
publishDate 2016-10-01
publisher Tehran University of Medical Sciences
record_format Article
series Journal of Tehran University Heart Center
spelling doaj.art-7b23b7ba5c7c4e969cd4d625069533002022-12-22T03:11:53ZengTehran University of Medical SciencesJournal of Tehran University Heart Center1735-86202008-23712016-10-01112430Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in NewbornsAmir Hosein Movahedian0Ziba Mosayebi1Setareh Sagheb2Tehran University of Medical Sciences, Tehran, Iran.Tehran University of Medical Sciences, Tehran, Iran.Tehran University of Medical Sciences, Tehran, Iran.Background: Delayed or missed diagnosis of critical and cyanotic congenital heart disease (CHD) in asymptomatic newborns may result in significant morbidity and mortality. The aim of this study was to determine the accuracy of pulse oximetry screening  performed on the first day of life for the early detection of critical and cyanotic CHD in apparently normal newborns. Methods: This cross-sectional study used postductal pulse oximetry to evaluate term neonates born between 2008 and 2011 with normal physical examinations. Functional oxygen saturation < 95% was considered abnormal, and second measurement was done 2 hours later. If the second measurement remained < 95%, an echocardiogram was performed. On enrolment in the study, the following data for each neonate were recorded: gestational age, gender, birth weight, mode of delivery, and mother’s age. Results: During the study period, totally 3,846 newborns were evaluated. Of the whole study population, 304 (7.9%) babies  had a  postductal functional saturation < 95%. The second measurement was also < 95% in 104 (2.7%) neonates. The mean age of the neonates at the time of pulse oximetry was 18.91 ± 8.61 (min = 4.5 and max = 49) hours. Forty-nine percent of the subjects were female and 51% were male. Echocardiography was performed on 81 out of 104 newborns, and 14 (0.36%) of them had CHD. The types of CHD in our patients were tetralogy of Fallot (3 cases), transposition of the great vessels (2 cases), double-outlet right ventricle (2 cases), truncus arteriosus, total anomalous pulmonary venous return, atrioventricular septal defect, pulmonary atresia, persistent pulmonary hypertension, ventricular septal defect, and atrial septal defect (1 case for each type). The best time for pulse oximetry was within 8-24 hours of the newborns’ life. Conclusion: Pulse oximetry screening along with clinical examination may be able to assist in the early detection of critical and cyanotic CHD in asymptomatic newborns.https://jthc.tums.ac.ir/index.php/jthc/article/view/583Congenitalhereditaryand neonatal diseases and abnormalities • Heart defectscongenital • Infantnew born • Oximetry
spellingShingle Amir Hosein Movahedian
Ziba Mosayebi
Setareh Sagheb
Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in Newborns
Journal of Tehran University Heart Center
Congenital
hereditary
and neonatal diseases and abnormalities • Heart defects
congenital • Infant
new born • Oximetry
title Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in Newborns
title_full Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in Newborns
title_fullStr Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in Newborns
title_full_unstemmed Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in Newborns
title_short Evaluation of Pulse Oximetry in the Early Detection of Cyanotic Congenital Heart Disease in Newborns
title_sort evaluation of pulse oximetry in the early detection of cyanotic congenital heart disease in newborns
topic Congenital
hereditary
and neonatal diseases and abnormalities • Heart defects
congenital • Infant
new born • Oximetry
url https://jthc.tums.ac.ir/index.php/jthc/article/view/583
work_keys_str_mv AT amirhoseinmovahedian evaluationofpulseoximetryintheearlydetectionofcyanoticcongenitalheartdiseaseinnewborns
AT zibamosayebi evaluationofpulseoximetryintheearlydetectionofcyanoticcongenitalheartdiseaseinnewborns
AT setarehsagheb evaluationofpulseoximetryintheearlydetectionofcyanoticcongenitalheartdiseaseinnewborns