Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola Response

Operating clinical analyzers within recommended parameters can be challenging during outbreak response. Using the Piccolo Xpress point-of-care blood chemistry analyzer on guinea pig blood, we found that values of many analytes are still readily comparable when samples and reagent discs are handled a...

Full description

Bibliographic Details
Main Authors: Jessica R. Spengler, Stephen R. Welch, Sarah C. Genzer, JoAnn Coleman-McCray, Jessica R. Harmon, Stuart T. Nichol, Christina F. Spiropoulou
Format: Article
Language:English
Published: Centers for Disease Control and Prevention 2019-06-01
Series:Emerging Infectious Diseases
Subjects:
Online Access:https://wwwnc.cdc.gov/eid/article/25/6/18-1928_article
_version_ 1828237711030353920
author Jessica R. Spengler
Stephen R. Welch
Sarah C. Genzer
JoAnn Coleman-McCray
Jessica R. Harmon
Stuart T. Nichol
Christina F. Spiropoulou
author_facet Jessica R. Spengler
Stephen R. Welch
Sarah C. Genzer
JoAnn Coleman-McCray
Jessica R. Harmon
Stuart T. Nichol
Christina F. Spiropoulou
author_sort Jessica R. Spengler
collection DOAJ
description Operating clinical analyzers within recommended parameters can be challenging during outbreak response. Using the Piccolo Xpress point-of-care blood chemistry analyzer on guinea pig blood, we found that values of many analytes are still readily comparable when samples and reagent discs are handled at various conditions outside of manufacturer recommendations.
first_indexed 2024-04-12T20:52:32Z
format Article
id doaj.art-7b601afbc2834c16a973da09188cd30a
institution Directory Open Access Journal
issn 1080-6040
1080-6059
language English
last_indexed 2024-04-12T20:52:32Z
publishDate 2019-06-01
publisher Centers for Disease Control and Prevention
record_format Article
series Emerging Infectious Diseases
spelling doaj.art-7b601afbc2834c16a973da09188cd30a2022-12-22T03:17:05ZengCenters for Disease Control and PreventionEmerging Infectious Diseases1080-60401080-60592019-06-012561238124010.3201/eid2506.181928Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola ResponseJessica R. SpenglerStephen R. WelchSarah C. GenzerJoAnn Coleman-McCrayJessica R. HarmonStuart T. NicholChristina F. SpiropoulouOperating clinical analyzers within recommended parameters can be challenging during outbreak response. Using the Piccolo Xpress point-of-care blood chemistry analyzer on guinea pig blood, we found that values of many analytes are still readily comparable when samples and reagent discs are handled at various conditions outside of manufacturer recommendations.https://wwwnc.cdc.gov/eid/article/25/6/18-1928_articleclinical chemistryfield studiesoutbreak responsemobile treatment unitpoint-of-careEbola
spellingShingle Jessica R. Spengler
Stephen R. Welch
Sarah C. Genzer
JoAnn Coleman-McCray
Jessica R. Harmon
Stuart T. Nichol
Christina F. Spiropoulou
Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola Response
Emerging Infectious Diseases
clinical chemistry
field studies
outbreak response
mobile treatment unit
point-of-care
Ebola
title Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola Response
title_full Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola Response
title_fullStr Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola Response
title_full_unstemmed Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola Response
title_short Suboptimal Handling of Piccolo Samples or Reagent Discs for Consideration in Ebola Response
title_sort suboptimal handling of piccolo samples or reagent discs for consideration in ebola response
topic clinical chemistry
field studies
outbreak response
mobile treatment unit
point-of-care
Ebola
url https://wwwnc.cdc.gov/eid/article/25/6/18-1928_article
work_keys_str_mv AT jessicarspengler suboptimalhandlingofpiccolosamplesorreagentdiscsforconsiderationinebolaresponse
AT stephenrwelch suboptimalhandlingofpiccolosamplesorreagentdiscsforconsiderationinebolaresponse
AT sarahcgenzer suboptimalhandlingofpiccolosamplesorreagentdiscsforconsiderationinebolaresponse
AT joanncolemanmccray suboptimalhandlingofpiccolosamplesorreagentdiscsforconsiderationinebolaresponse
AT jessicarharmon suboptimalhandlingofpiccolosamplesorreagentdiscsforconsiderationinebolaresponse
AT stuarttnichol suboptimalhandlingofpiccolosamplesorreagentdiscsforconsiderationinebolaresponse
AT christinafspiropoulou suboptimalhandlingofpiccolosamplesorreagentdiscsforconsiderationinebolaresponse