Sensorless Rotor Position Determination of PSMS Focusing on HF Signal Injection Method
The paper deal with HF injection method for rotor position determination of sensorless permanent magnet sychronoous motor (PMSM) drive. Special attention is paid to generation - and injection of HF signal as well as to filtering of positive component of current HF vector. The results of simulation e...
Main Authors: | Roman Filka, Branislav Dobrucky |
---|---|
Format: | Article |
Language: | English |
Published: |
VSB-Technical University of Ostrava
2002-01-01
|
Series: | Advances in Electrical and Electronic Engineering |
Subjects: | |
Online Access: | http://advances.utc.sk/index.php/AEEE/article/view/351 |
Similar Items
-
Position Sensorless Vector Control System for Lawnmower Permanent Magnet Synchronous Motor Based on Extended Kalman Filter
by: Dongri Shan, et al.
Published: (2024-03-01) -
A Sensorless PM Synchronous Motor Drive for Electric Washers
by: R. Filka, et al.
Published: (2007-03-01) -
Surface Permanent Magnet Synchronous Motors’ Passive Sensorless Control: A Review
by: Alessandro Benevieri, et al.
Published: (2022-10-01) -
Overview of Position-Sensorless Technology for Permanent Magnet Synchronous Motor Systems
by: Yulei Xu, et al.
Published: (2023-08-01) -
Rotor Position Alignment of FSTPI Based PMSM Drive Using Low Frequency Signal Injection
by: Salih Baris Ozturk, et al.
Published: (2020-10-01)