Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparison

Abstract Objective For patients with cystic fibrosis, the imaging of the pancreas is of crucial importance for the early detection of pancreatic carcinoma. Comparative studies between Magnetic Resonance Imaging (MRI) and sonographic pancreas sonography are not yet available. The aim of the study was...

Full description

Bibliographic Details
Main Authors: Christopher Kloth, Dorit Fabricius, Inka Wendlik, Stefan Andreas Schmidt, Matthias Pfahler, Elisabeth Lormes, Meinrad Beer, Wolfgang Kratzer, Julian Schmidberger
Format: Article
Language:English
Published: BMC 2019-03-01
Series:BMC Research Notes
Subjects:
Online Access:http://link.springer.com/article/10.1186/s13104-019-4193-4
_version_ 1818337213938663424
author Christopher Kloth
Dorit Fabricius
Inka Wendlik
Stefan Andreas Schmidt
Matthias Pfahler
Elisabeth Lormes
Meinrad Beer
Wolfgang Kratzer
Julian Schmidberger
author_facet Christopher Kloth
Dorit Fabricius
Inka Wendlik
Stefan Andreas Schmidt
Matthias Pfahler
Elisabeth Lormes
Meinrad Beer
Wolfgang Kratzer
Julian Schmidberger
author_sort Christopher Kloth
collection DOAJ
description Abstract Objective For patients with cystic fibrosis, the imaging of the pancreas is of crucial importance for the early detection of pancreatic carcinoma. Comparative studies between Magnetic Resonance Imaging (MRI) and sonographic pancreas sonography are not yet available. The aim of the study was to compare MRI, sonography and point-shearwave elastography (pSWE). A total of 19 patients were included (10 male, 9 female; age 29.7 ± 14.3 years) in the study. Ultrasonography with pSWE and contrast enhanced MRI with MRCP were performed. Results Significant differences between measurements of pancreatic body were registered in MRI with 1.4 ± 0.6 cm vs 1.0 ± 0.4 cm in ultrasound (p = 0.049), however not for pancreatic head and tail. In 10/19 patients (52.6%) pancreatic parenchyma did not show in MRI because of complete lipomatous transformation, but could be detected in ultrasound. pSWE-values showed no significant differences between the full and partial fatty transformation in pancreatic head (p = 0.968), body (p = 0.657) and tail (p = 0.840). pSWE-values did not correlate with measured signal intensity in T1w flash (p = 0.930, r = 0.025) and T2w HASTE sequences (p = 0.152, r = − 0.375). In patients with CF ultrasound is superior to MRI for displaying full fibro-fatty parenchymal transformation, pancreatic duct. Ultrasound elastography did not provide additional clinical relevant information.
first_indexed 2024-12-13T14:51:39Z
format Article
id doaj.art-7b80316392764eb9a8c5bba67d27a5c8
institution Directory Open Access Journal
issn 1756-0500
language English
last_indexed 2024-12-13T14:51:39Z
publishDate 2019-03-01
publisher BMC
record_format Article
series BMC Research Notes
spelling doaj.art-7b80316392764eb9a8c5bba67d27a5c82022-12-21T23:41:20ZengBMCBMC Research Notes1756-05002019-03-011211710.1186/s13104-019-4193-4Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparisonChristopher Kloth0Dorit Fabricius1Inka Wendlik2Stefan Andreas Schmidt3Matthias Pfahler4Elisabeth Lormes5Meinrad Beer6Wolfgang Kratzer7Julian Schmidberger8Department of Diagnostic and Interventional Radiology, University Hospital UlmDepartment of Paediatric and Adolescent Medicine, Ulm University HospitalsDepartment of Diagnostic and Interventional Radiology, University Hospital UlmDepartment of Diagnostic and Interventional Radiology, University Hospital UlmDepartment of Internal Medicine I, University Hospital UlmDepartment of Dermatology and Allergic Diseases, Ulm University HospitalDepartment of Diagnostic and Interventional Radiology, University Hospital UlmDepartment of Internal Medicine I, University Hospital UlmDepartment of Internal Medicine I, University Hospital UlmAbstract Objective For patients with cystic fibrosis, the imaging of the pancreas is of crucial importance for the early detection of pancreatic carcinoma. Comparative studies between Magnetic Resonance Imaging (MRI) and sonographic pancreas sonography are not yet available. The aim of the study was to compare MRI, sonography and point-shearwave elastography (pSWE). A total of 19 patients were included (10 male, 9 female; age 29.7 ± 14.3 years) in the study. Ultrasonography with pSWE and contrast enhanced MRI with MRCP were performed. Results Significant differences between measurements of pancreatic body were registered in MRI with 1.4 ± 0.6 cm vs 1.0 ± 0.4 cm in ultrasound (p = 0.049), however not for pancreatic head and tail. In 10/19 patients (52.6%) pancreatic parenchyma did not show in MRI because of complete lipomatous transformation, but could be detected in ultrasound. pSWE-values showed no significant differences between the full and partial fatty transformation in pancreatic head (p = 0.968), body (p = 0.657) and tail (p = 0.840). pSWE-values did not correlate with measured signal intensity in T1w flash (p = 0.930, r = 0.025) and T2w HASTE sequences (p = 0.152, r = − 0.375). In patients with CF ultrasound is superior to MRI for displaying full fibro-fatty parenchymal transformation, pancreatic duct. Ultrasound elastography did not provide additional clinical relevant information.http://link.springer.com/article/10.1186/s13104-019-4193-4Cystic fibrosisPancreasMRI imagingB-mode sonographyShear wave elastography
spellingShingle Christopher Kloth
Dorit Fabricius
Inka Wendlik
Stefan Andreas Schmidt
Matthias Pfahler
Elisabeth Lormes
Meinrad Beer
Wolfgang Kratzer
Julian Schmidberger
Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparison
BMC Research Notes
Cystic fibrosis
Pancreas
MRI imaging
B-mode sonography
Shear wave elastography
title Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparison
title_full Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparison
title_fullStr Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparison
title_full_unstemmed Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparison
title_short Diagnostic accuracy of MRI with MRCP and B-Mode-sonography with elastography of the pancreas in patients with cystic fibrosis: a point-to-point comparison
title_sort diagnostic accuracy of mri with mrcp and b mode sonography with elastography of the pancreas in patients with cystic fibrosis a point to point comparison
topic Cystic fibrosis
Pancreas
MRI imaging
B-mode sonography
Shear wave elastography
url http://link.springer.com/article/10.1186/s13104-019-4193-4
work_keys_str_mv AT christopherkloth diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT doritfabricius diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT inkawendlik diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT stefanandreasschmidt diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT matthiaspfahler diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT elisabethlormes diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT meinradbeer diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT wolfgangkratzer diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison
AT julianschmidberger diagnosticaccuracyofmriwithmrcpandbmodesonographywithelastographyofthepancreasinpatientswithcysticfibrosisapointtopointcomparison