Effect of vertical circular openings on flexural strength of reinforced concrete beam

Modern building construction techniques sometimes involve the passing of pipes or ducts for water supply, electrification, and telecommunication through reinforced concrete beams to protect them against mechanical damages and add aesthetic value to buildings. This study looks into the effect of vert...

Full description

Bibliographic Details
Main Authors: Auta Samuel Mahuta, Jamiu Oladipo, Alhaji Bala
Format: Article
Language:English
Published: Peter the Great St. Petersburg Polytechnic University 2021-10-01
Series:Magazine of Civil Engineering
Subjects:
Online Access:http://engstroy.spbstu.ru/article/2021.106.01/
_version_ 1819008963736240128
author Auta Samuel Mahuta
Jamiu Oladipo
Alhaji Bala
author_facet Auta Samuel Mahuta
Jamiu Oladipo
Alhaji Bala
author_sort Auta Samuel Mahuta
collection DOAJ
description Modern building construction techniques sometimes involve the passing of pipes or ducts for water supply, electrification, and telecommunication through reinforced concrete beams to protect them against mechanical damages and add aesthetic value to buildings. This study looks into the effect of vertical circular openings on the flexural strength of the reinforced concrete beam. Two (2) sets of beam samples were investigated during this study: computer simulated reinforced concrete (RC) beam using ANSYS 19.1 and laboratory cast. The results of the flexural strength test conducted show the following: Reinforced concrete beam with vertical circular openings of diameter greater than 33.3 % of beam width (B) reduced its flexural strength by at least 20 %; maximum compressive stress of concrete occurs at the openings region of the beam; the difference in ultimate load capacity of finite element (FE) beam models and experimental beam specimen is 3.5 %. It can be deduced that ANSYS software is an appropriate finite element (FE) tool to predict the behaviour of RC beams. Hence, it is hereby recommended that the diameter of the vertical circular opening in RC beam should not exceed 33.3 % of the beam width and its location from beam support should not exceed L/6.
first_indexed 2024-12-21T00:48:50Z
format Article
id doaj.art-7b92aabb6f314ac29f7cdb9b120d0de3
institution Directory Open Access Journal
issn 2712-8172
language English
last_indexed 2024-12-21T00:48:50Z
publishDate 2021-10-01
publisher Peter the Great St. Petersburg Polytechnic University
record_format Article
series Magazine of Civil Engineering
spelling doaj.art-7b92aabb6f314ac29f7cdb9b120d0de32022-12-21T19:21:27ZengPeter the Great St. Petersburg Polytechnic UniversityMagazine of Civil Engineering2712-81722021-10-011060610.34910/MCE.106.120714726Effect of vertical circular openings on flexural strength of reinforced concrete beamAuta Samuel Mahuta0https://orcid.org/0000-0003-0413-3946Jamiu Oladipo1Alhaji Bala2Federal University of Technology MinnaFederal University of Technology MinnaFederal University of Technology MinnaModern building construction techniques sometimes involve the passing of pipes or ducts for water supply, electrification, and telecommunication through reinforced concrete beams to protect them against mechanical damages and add aesthetic value to buildings. This study looks into the effect of vertical circular openings on the flexural strength of the reinforced concrete beam. Two (2) sets of beam samples were investigated during this study: computer simulated reinforced concrete (RC) beam using ANSYS 19.1 and laboratory cast. The results of the flexural strength test conducted show the following: Reinforced concrete beam with vertical circular openings of diameter greater than 33.3 % of beam width (B) reduced its flexural strength by at least 20 %; maximum compressive stress of concrete occurs at the openings region of the beam; the difference in ultimate load capacity of finite element (FE) beam models and experimental beam specimen is 3.5 %. It can be deduced that ANSYS software is an appropriate finite element (FE) tool to predict the behaviour of RC beams. Hence, it is hereby recommended that the diameter of the vertical circular opening in RC beam should not exceed 33.3 % of the beam width and its location from beam support should not exceed L/6.http://engstroy.spbstu.ru/article/2021.106.01/verticalcircularopeningsflexuralstrengthansysbuilding
spellingShingle Auta Samuel Mahuta
Jamiu Oladipo
Alhaji Bala
Effect of vertical circular openings on flexural strength of reinforced concrete beam
Magazine of Civil Engineering
vertical
circular
openings
flexural
strength
ansys
building
title Effect of vertical circular openings on flexural strength of reinforced concrete beam
title_full Effect of vertical circular openings on flexural strength of reinforced concrete beam
title_fullStr Effect of vertical circular openings on flexural strength of reinforced concrete beam
title_full_unstemmed Effect of vertical circular openings on flexural strength of reinforced concrete beam
title_short Effect of vertical circular openings on flexural strength of reinforced concrete beam
title_sort effect of vertical circular openings on flexural strength of reinforced concrete beam
topic vertical
circular
openings
flexural
strength
ansys
building
url http://engstroy.spbstu.ru/article/2021.106.01/
work_keys_str_mv AT autasamuelmahuta effectofverticalcircularopeningsonflexuralstrengthofreinforcedconcretebeam
AT jamiuoladipo effectofverticalcircularopeningsonflexuralstrengthofreinforcedconcretebeam
AT alhajibala effectofverticalcircularopeningsonflexuralstrengthofreinforcedconcretebeam