Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments
Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Academia Brasileira de Ciências
2012-12-01
|
Series: | Anais da Academia Brasileira de Ciências |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652012000400030 |
_version_ | 1830449094894551040 |
---|---|
author | Lai K. Wee Hum Y. Chai Sharul R. Bin Samsury Naizaithull F. Binti Mujamil Eko Supriyanto |
author_facet | Lai K. Wee Hum Y. Chai Sharul R. Bin Samsury Naizaithull F. Binti Mujamil Eko Supriyanto |
author_sort | Lai K. Wee |
collection | DOAJ |
description | Current two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.<br>As atuais medições bidimensionais (2D) com marcadores ultrassônicos com inerentes intra- e interobservadores têm limitações de variabilidade. O objetivo deste trabalho é investigar o desempenho de medições convencionais 2D com marcador ultrassom e uma proposta interativa tridimensional programável de avaliação com marcador (3D). Isto é essencialmente importante para analisar que a medição em 3D volumétrica possui maior impacto e medição de reprodutibilidade vis-à-vis a 2D. Vinte e três casos de ultrassonografia pré-natal foram obtidos do hospital que colaborou com a pesquisa após a aprovação pela Comissão de Ética. A medida do marcador 2D ultrassônica é Translucência Nucal ou comumente abreviado como NT. A análise descritiva de medição de ultrassom 2D e 3D foram calculados. Três medidas foram obtidas em ensaios para cada método. Ambos os dados foram testados com uma amostra de teste de Kolmogorov-Smirnov e os resultados indicam que as medições de marcadores foram distribuídos normalmente com significativos valores paramétricos de 0, 621 e 0, 596, respectivamente. A média e o desvio padrão para ambos os métodos de medição são 1, 4495 ± 0, 46490 (2D) e 1, 3561 ± 0, 50994 (3D).O teste ANOVA mostrou que medições computadorizadas 3D foram insignificantemente diferentes da média 2D convencional com nível de significância de 0, 05. Com coeficiente de correlação de Pearson com valor R = 0, 861, o resultado comprova forte correlação linear positiva entre medidas ultrassônicas 2D e 3D. Reprodutibilidade e exatidão do ultrassom 3D na medida da TN foram significativamente aumentadas em comparação com a avaliação ultrassom 2D na modalidade B-pré-natal. Imagem reconstruída em 3D tem maiores valores clínicos em comparção com as imagens de ultrassom 2D que possuem menos informações para diagnóstico. |
first_indexed | 2024-12-21T07:48:46Z |
format | Article |
id | doaj.art-7bbd29d7890c49f3a2aed948e71c1289 |
institution | Directory Open Access Journal |
issn | 0001-3765 1678-2690 |
language | English |
last_indexed | 2024-12-21T07:48:46Z |
publishDate | 2012-12-01 |
publisher | Academia Brasileira de Ciências |
record_format | Article |
series | Anais da Academia Brasileira de Ciências |
spelling | doaj.art-7bbd29d7890c49f3a2aed948e71c12892022-12-21T19:11:08ZengAcademia Brasileira de CiênciasAnais da Academia Brasileira de Ciências0001-37651678-26902012-12-018441157116810.1590/S0001-37652012000400030Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessmentsLai K. WeeHum Y. ChaiSharul R. Bin SamsuryNaizaithull F. Binti MujamilEko SupriyantoCurrent two-dimensional (2D) ultrasonic marker measurements are inherent with intra- and inter-observer variability limitations. The objective of this paper is to investigate the performance of conventional 2D ultrasonic marker measurements and proposed programmable interactive three-dimensional (3D) marker evaluation. This is essentially important to analyze that the measurement on 3D volumetric measurement possesses higher impact and reproducibility vis-à-vis 2D measurement. Twenty three cases of prenatal ultrasound examination were obtained from collaborating hospital after Ethical Committee's approval. The measured 2D ultrasonic marker is Nuchal Translucency or commonly abbreviated as NT. Descriptive analysis of both 2D and 3D ultrasound measurement were calculated. Three trial measurements were taken for each method. Both data were tested with One-Sample Kolmogorov-Smirnov Test and results indicate that markers measurements were distributed normally with significant parametric values at 0.621 and 0.596 respectively. Computed mean and standard deviation for both measurement methods are 1.4495 ± 0.46490 (2D) and 1.3561 ± 0.50994 (3D). ANOVA test shows that computerized 3D measurements were found to be insignificantly different from the mean of conventional 2D at the significance level of 0.05. With Pearson's correlation coefficient value or R = 0.861, the result proves strong positive linear correlation between 2D and 3D ultrasonic measurements. Reproducibility and accuracy of 3D ultrasound in NT measurement was significantly increased compared with 2D B-mode ultrasound prenatal assessment. 3D reconstructed imaging has higher clinical values compare to 2D ultrasound images with less diagnostics information.<br>As atuais medições bidimensionais (2D) com marcadores ultrassônicos com inerentes intra- e interobservadores têm limitações de variabilidade. O objetivo deste trabalho é investigar o desempenho de medições convencionais 2D com marcador ultrassom e uma proposta interativa tridimensional programável de avaliação com marcador (3D). Isto é essencialmente importante para analisar que a medição em 3D volumétrica possui maior impacto e medição de reprodutibilidade vis-à-vis a 2D. Vinte e três casos de ultrassonografia pré-natal foram obtidos do hospital que colaborou com a pesquisa após a aprovação pela Comissão de Ética. A medida do marcador 2D ultrassônica é Translucência Nucal ou comumente abreviado como NT. A análise descritiva de medição de ultrassom 2D e 3D foram calculados. Três medidas foram obtidas em ensaios para cada método. Ambos os dados foram testados com uma amostra de teste de Kolmogorov-Smirnov e os resultados indicam que as medições de marcadores foram distribuídos normalmente com significativos valores paramétricos de 0, 621 e 0, 596, respectivamente. A média e o desvio padrão para ambos os métodos de medição são 1, 4495 ± 0, 46490 (2D) e 1, 3561 ± 0, 50994 (3D).O teste ANOVA mostrou que medições computadorizadas 3D foram insignificantemente diferentes da média 2D convencional com nível de significância de 0, 05. Com coeficiente de correlação de Pearson com valor R = 0, 861, o resultado comprova forte correlação linear positiva entre medidas ultrassônicas 2D e 3D. Reprodutibilidade e exatidão do ultrassom 3D na medida da TN foram significativamente aumentadas em comparação com a avaliação ultrassom 2D na modalidade B-pré-natal. Imagem reconstruída em 3D tem maiores valores clínicos em comparção com as imagens de ultrassom 2D que possuem menos informações para diagnóstico.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652012000400030três dimensões (3D)ultrassonografiamedida da translucência nucal (TN)espessura da pregaTrissomiasíndrome de Downthree dimensional (3D)ultrasoundnuchal translucency (NT)fold thicknessTrisomyDown Syndrome |
spellingShingle | Lai K. Wee Hum Y. Chai Sharul R. Bin Samsury Naizaithull F. Binti Mujamil Eko Supriyanto Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments Anais da Academia Brasileira de Ciências três dimensões (3D) ultrassonografia medida da translucência nucal (TN) espessura da prega Trissomia síndrome de Down three dimensional (3D) ultrasound nuchal translucency (NT) fold thickness Trisomy Down Syndrome |
title | Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments |
title_full | Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments |
title_fullStr | Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments |
title_full_unstemmed | Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments |
title_short | Comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments |
title_sort | comparative studies of two dimensional and three dimensional ultrasonic nuchal translucency in trisomy assessments |
topic | três dimensões (3D) ultrassonografia medida da translucência nucal (TN) espessura da prega Trissomia síndrome de Down three dimensional (3D) ultrasound nuchal translucency (NT) fold thickness Trisomy Down Syndrome |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652012000400030 |
work_keys_str_mv | AT laikwee comparativestudiesoftwodimensionalandthreedimensionalultrasonicnuchaltranslucencyintrisomyassessments AT humychai comparativestudiesoftwodimensionalandthreedimensionalultrasonicnuchaltranslucencyintrisomyassessments AT sharulrbinsamsury comparativestudiesoftwodimensionalandthreedimensionalultrasonicnuchaltranslucencyintrisomyassessments AT naizaithullfbintimujamil comparativestudiesoftwodimensionalandthreedimensionalultrasonicnuchaltranslucencyintrisomyassessments AT ekosupriyanto comparativestudiesoftwodimensionalandthreedimensionalultrasonicnuchaltranslucencyintrisomyassessments |