Self-reference method of near-field measurement

For high integrated antenna, certain method must be adopted achieve accurate and effective detection of amplitude and phase information of array. However, traditional method (including near-field calibration, FFT, etc.) all need to obtain phase information, so the antenna needs to provide reference...

Full description

Bibliographic Details
Main Authors: Du Yan, Yang Shunping
Format: Article
Language:zho
Published: National Computer System Engineering Research Institute of China 2019-08-01
Series:Dianzi Jishu Yingyong
Subjects:
Online Access:http://www.chinaaet.com/article/3000107567
_version_ 1819068084199096320
author Du Yan
Yang Shunping
author_facet Du Yan
Yang Shunping
author_sort Du Yan
collection DOAJ
description For high integrated antenna, certain method must be adopted achieve accurate and effective detection of amplitude and phase information of array. However, traditional method (including near-field calibration, FFT, etc.) all need to obtain phase information, so the antenna needs to provide reference channel for testing. This is contrary to the high integration of antenna, and also puts forward higher requirements for antenna designation, especially for the conformal antenna. In order to solve the problem that the traditional method relies on the parameter channel to provide reference phase, a self-reference method is designed for the near-field measurement, a test troubleshooting scenatio commonly used by high integrated antennas. The test results show that the results of the near-field test using the self-reference method are highly consistent with the test results of the traditional near-field measurement system with independent reference channel. In addition, self-reference method, which does not need a separate reference channel, is suitable for the near-field test of highly integrated antenna, which is of great significance for the field test arrangement of installed antenna.
first_indexed 2024-12-21T16:28:27Z
format Article
id doaj.art-7bcee71b5b2d4bb2a7c486009a0ca929
institution Directory Open Access Journal
issn 0258-7998
language zho
last_indexed 2024-12-21T16:28:27Z
publishDate 2019-08-01
publisher National Computer System Engineering Research Institute of China
record_format Article
series Dianzi Jishu Yingyong
spelling doaj.art-7bcee71b5b2d4bb2a7c486009a0ca9292022-12-21T18:57:24ZzhoNational Computer System Engineering Research Institute of ChinaDianzi Jishu Yingyong0258-79982019-08-01458919410.16157/j.issn.0258-7998.1900513000107567Self-reference method of near-field measurementDu Yan0Yang Shunping1Southwest China Insitute of Electronic Technology,Chengdu 610036,ChinaSouthwest China Insitute of Electronic Technology,Chengdu 610036,ChinaFor high integrated antenna, certain method must be adopted achieve accurate and effective detection of amplitude and phase information of array. However, traditional method (including near-field calibration, FFT, etc.) all need to obtain phase information, so the antenna needs to provide reference channel for testing. This is contrary to the high integration of antenna, and also puts forward higher requirements for antenna designation, especially for the conformal antenna. In order to solve the problem that the traditional method relies on the parameter channel to provide reference phase, a self-reference method is designed for the near-field measurement, a test troubleshooting scenatio commonly used by high integrated antennas. The test results show that the results of the near-field test using the self-reference method are highly consistent with the test results of the traditional near-field measurement system with independent reference channel. In addition, self-reference method, which does not need a separate reference channel, is suitable for the near-field test of highly integrated antenna, which is of great significance for the field test arrangement of installed antenna.http://www.chinaaet.com/article/3000107567self-reference methodnear-field measurementhigh-densityphased array
spellingShingle Du Yan
Yang Shunping
Self-reference method of near-field measurement
Dianzi Jishu Yingyong
self-reference method
near-field measurement
high-density
phased array
title Self-reference method of near-field measurement
title_full Self-reference method of near-field measurement
title_fullStr Self-reference method of near-field measurement
title_full_unstemmed Self-reference method of near-field measurement
title_short Self-reference method of near-field measurement
title_sort self reference method of near field measurement
topic self-reference method
near-field measurement
high-density
phased array
url http://www.chinaaet.com/article/3000107567
work_keys_str_mv AT duyan selfreferencemethodofnearfieldmeasurement
AT yangshunping selfreferencemethodofnearfieldmeasurement