A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid

Repetitive control (RC) is gradually used in inverters tied with weak grid. To achieve the zero steady-state error tracking of inverter current and compensate the harmonic distortion caused by frequency fluctuation, a frequency adaptive (FA) control scheme for LCL-type inverter connected with weak g...

Full description

Bibliographic Details
Main Authors: Chengbi Zeng, Sudan Li, Hanwen Wang, Hong Miao
Format: Article
Language:English
Published: MDPI AG 2021-07-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/14/14/4225
_version_ 1797527239216070656
author Chengbi Zeng
Sudan Li
Hanwen Wang
Hong Miao
author_facet Chengbi Zeng
Sudan Li
Hanwen Wang
Hong Miao
author_sort Chengbi Zeng
collection DOAJ
description Repetitive control (RC) is gradually used in inverters tied with weak grid. To achieve the zero steady-state error tracking of inverter current and compensate the harmonic distortion caused by frequency fluctuation, a frequency adaptive (FA) control scheme for LCL-type inverter connected with weak grid is proposed. This scheme adopts a proportional resonance (PR) controller in parallel with RC (PRRC) to overcome the disadvantages caused by RC inherent one-cycle time delay. A fractional delay (FD) filter based on the Newton structure is proposed to approximate the fraction item of <i>f<sub>s</sub></i>/<i>f</i>, where <i>f<sub>s</sub></i> and <i>f</i> are sample frequency and grid frequency, respectively. The structure of the proposed FD filter is relatively simple; moreover, coefficients of the filter maintain constant so as not to need online tuning even when grid frequency fluctuates, which decreases the computational burden considerably. The feasibility and effectiveness of the proposed FA control scheme, named as Newton-FAPRRC, are all verified by the simulation and experimental results.
first_indexed 2024-03-10T09:40:14Z
format Article
id doaj.art-7bef547cb44f4146961bc50f05dca18c
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-10T09:40:14Z
publishDate 2021-07-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-7bef547cb44f4146961bc50f05dca18c2023-11-22T03:42:09ZengMDPI AGEnergies1996-10732021-07-011414422510.3390/en14144225A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak GridChengbi Zeng0Sudan Li1Hanwen Wang2Hong Miao3College of Electrical Engineering, Sichuan University, Chengdu 610065, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu 610065, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu 610065, ChinaCollege of Electrical Engineering, Sichuan University, Chengdu 610065, ChinaRepetitive control (RC) is gradually used in inverters tied with weak grid. To achieve the zero steady-state error tracking of inverter current and compensate the harmonic distortion caused by frequency fluctuation, a frequency adaptive (FA) control scheme for LCL-type inverter connected with weak grid is proposed. This scheme adopts a proportional resonance (PR) controller in parallel with RC (PRRC) to overcome the disadvantages caused by RC inherent one-cycle time delay. A fractional delay (FD) filter based on the Newton structure is proposed to approximate the fraction item of <i>f<sub>s</sub></i>/<i>f</i>, where <i>f<sub>s</sub></i> and <i>f</i> are sample frequency and grid frequency, respectively. The structure of the proposed FD filter is relatively simple; moreover, coefficients of the filter maintain constant so as not to need online tuning even when grid frequency fluctuates, which decreases the computational burden considerably. The feasibility and effectiveness of the proposed FA control scheme, named as Newton-FAPRRC, are all verified by the simulation and experimental results.https://www.mdpi.com/1996-1073/14/14/4225repetitive control (RC)weak gridfrequency adaptive (FA)Newton structurefractional delay (FD) filter
spellingShingle Chengbi Zeng
Sudan Li
Hanwen Wang
Hong Miao
A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid
Energies
repetitive control (RC)
weak grid
frequency adaptive (FA)
Newton structure
fractional delay (FD) filter
title A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid
title_full A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid
title_fullStr A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid
title_full_unstemmed A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid
title_short A Frequency Adaptive Scheme Based on Newton Structure of PRRC for LCL-Type Inverter Connected with Weak Grid
title_sort frequency adaptive scheme based on newton structure of prrc for lcl type inverter connected with weak grid
topic repetitive control (RC)
weak grid
frequency adaptive (FA)
Newton structure
fractional delay (FD) filter
url https://www.mdpi.com/1996-1073/14/14/4225
work_keys_str_mv AT chengbizeng afrequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid
AT sudanli afrequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid
AT hanwenwang afrequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid
AT hongmiao afrequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid
AT chengbizeng frequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid
AT sudanli frequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid
AT hanwenwang frequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid
AT hongmiao frequencyadaptiveschemebasedonnewtonstructureofprrcforlcltypeinverterconnectedwithweakgrid