A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-Shifting

We report a novel fully real-time automatized optomechatronic dual-aperture common-path interferometer system for obtaining the phase difference between two interferograms by using the technique of phase-shifting interferometry. A motorized system is used to shift an additional phase transversally t...

Full description

Bibliographic Details
Main Authors: Antonio Barcelata-Pinzón, Ricardo Iván Álvarez-Tamayo, Patricia Prieto-Cortés
Format: Article
Language:English
Published: MDPI AG 2021-08-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/11/16/7438
_version_ 1797524782800961536
author Antonio Barcelata-Pinzón
Ricardo Iván Álvarez-Tamayo
Patricia Prieto-Cortés
author_facet Antonio Barcelata-Pinzón
Ricardo Iván Álvarez-Tamayo
Patricia Prieto-Cortés
author_sort Antonio Barcelata-Pinzón
collection DOAJ
description We report a novel fully real-time automatized optomechatronic dual-aperture common-path interferometer system for obtaining the phase difference between two interferograms by using the technique of phase-shifting interferometry. A motorized system is used to shift an additional phase transversally to the optical axis by ruling translation. For each high-resolution ruling displacement step of 0.793 μm, an interferogram is recorded by a CCD camera. The phase difference between the two successive recorded interferograms is then automatically calculated by computational self-calibrated algorithms. The proposed device provides more accurate measuring than typically used manual processes. Real-time phase differences are obtained from a robust low-cost optomechatronic system. Analytical calculation of the phase is performed automatically without the requirement of additional or external tools and processes, reducing the significant rework delay. A set of 47 interferograms were captured in real time then recorded and analyzed, obtaining an average phase shifting of 2.483 rad. Analytic explanation and experimental results are presented.
first_indexed 2024-03-10T09:02:27Z
format Article
id doaj.art-7bf8cad5347f482cb26b724c16828472
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-10T09:02:27Z
publishDate 2021-08-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-7bf8cad5347f482cb26b724c168284722023-11-22T06:41:39ZengMDPI AGApplied Sciences2076-34172021-08-011116743810.3390/app11167438A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-ShiftingAntonio Barcelata-Pinzón0Ricardo Iván Álvarez-Tamayo1Patricia Prieto-Cortés2Mechatronics Division, Universidad Tecnológica de Puebla, Puebla 72300, MexicoFaculty of Mechatronics, Electronics, Bionics and Aerospace, Universidad Popular Autónoma del Estado de Puebla, Puebla 72410, MexicoFaculty of Physics and Mathematics, Universidad Autónoma de Nuevo León, San Nicolás de los Garza 66460, MexicoWe report a novel fully real-time automatized optomechatronic dual-aperture common-path interferometer system for obtaining the phase difference between two interferograms by using the technique of phase-shifting interferometry. A motorized system is used to shift an additional phase transversally to the optical axis by ruling translation. For each high-resolution ruling displacement step of 0.793 μm, an interferogram is recorded by a CCD camera. The phase difference between the two successive recorded interferograms is then automatically calculated by computational self-calibrated algorithms. The proposed device provides more accurate measuring than typically used manual processes. Real-time phase differences are obtained from a robust low-cost optomechatronic system. Analytical calculation of the phase is performed automatically without the requirement of additional or external tools and processes, reducing the significant rework delay. A set of 47 interferograms were captured in real time then recorded and analyzed, obtaining an average phase shifting of 2.483 rad. Analytic explanation and experimental results are presented.https://www.mdpi.com/2076-3417/11/16/7438generalized phase shifting interferometrydual-aperture common-path interferometerreal-time optical instrumentationoptomechatronic systems
spellingShingle Antonio Barcelata-Pinzón
Ricardo Iván Álvarez-Tamayo
Patricia Prieto-Cortés
A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-Shifting
Applied Sciences
generalized phase shifting interferometry
dual-aperture common-path interferometer
real-time optical instrumentation
optomechatronic systems
title A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-Shifting
title_full A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-Shifting
title_fullStr A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-Shifting
title_full_unstemmed A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-Shifting
title_short A Real-Time Automated System for Dual-Aperture Common-Path Interferometer Phase-Shifting
title_sort real time automated system for dual aperture common path interferometer phase shifting
topic generalized phase shifting interferometry
dual-aperture common-path interferometer
real-time optical instrumentation
optomechatronic systems
url https://www.mdpi.com/2076-3417/11/16/7438
work_keys_str_mv AT antoniobarcelatapinzon arealtimeautomatedsystemfordualaperturecommonpathinterferometerphaseshifting
AT ricardoivanalvareztamayo arealtimeautomatedsystemfordualaperturecommonpathinterferometerphaseshifting
AT patriciaprietocortes arealtimeautomatedsystemfordualaperturecommonpathinterferometerphaseshifting
AT antoniobarcelatapinzon realtimeautomatedsystemfordualaperturecommonpathinterferometerphaseshifting
AT ricardoivanalvareztamayo realtimeautomatedsystemfordualaperturecommonpathinterferometerphaseshifting
AT patriciaprietocortes realtimeautomatedsystemfordualaperturecommonpathinterferometerphaseshifting