Methodology of monitoring ice on wires with considering misalignment of power line armature
One of the most serious causes of accidents in high-power electric power systems is the formation of ice on the wires of high-voltage transmission lines (HVL). In this case, it should be noted that it is necessary to accurately localize the problematic ice area of a site or defect, since it is often...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Kazan State Power Engineering University
2017-12-01
|
Series: | Известия высших учебных заведений: Проблемы энергетики |
Subjects: | |
Online Access: | https://www.energyret.ru/jour/article/view/386 |
_version_ | 1797757970460704768 |
---|---|
author | D. A. Yaroslavskiy M. F. Sadykov A. B. Konov D. A. Ivanov M. P. Goryachev T. G. Yambaeva |
author_facet | D. A. Yaroslavskiy M. F. Sadykov A. B. Konov D. A. Ivanov M. P. Goryachev T. G. Yambaeva |
author_sort | D. A. Yaroslavskiy |
collection | DOAJ |
description | One of the most serious causes of accidents in high-power electric power systems is the formation of ice on the wires of high-voltage transmission lines (HVL). In this case, it should be noted that it is necessary to accurately localize the problematic ice area of a site or defect, since it is often difficult to travel along a high-voltage line. In addition, the effect of dragging the wire from one span to the other (misalignment) is observed on worn-out overhead power transmission lines. To solve the set tasks, there was a method for monitoring ice deposits on the overhead lines based on the mathematical model of the chain line, which makes it possible to determine the current sag and elongation of the wire in the span, the force of its tension, taking into account the misalignment of the wires on the line. Implementation of this technique will allow to detect the appearance of ice deposits on the overhead line, which allows timely implementation of measures to prevent emergency situations on the line (optimization of the melting schedule for ice on the wires). |
first_indexed | 2024-03-12T18:23:10Z |
format | Article |
id | doaj.art-7c0c9f0a123e4394bddb85fafb109f15 |
institution | Directory Open Access Journal |
issn | 1998-9903 |
language | English |
last_indexed | 2024-03-12T18:23:10Z |
publishDate | 2017-12-01 |
publisher | Kazan State Power Engineering University |
record_format | Article |
series | Известия высших учебных заведений: Проблемы энергетики |
spelling | doaj.art-7c0c9f0a123e4394bddb85fafb109f152023-08-02T08:41:46ZengKazan State Power Engineering UniversityИзвестия высших учебных заведений: Проблемы энергетики1998-99032017-12-01195-6899710.30724/1998-9903-2017-19-5-6-89-97386Methodology of monitoring ice on wires with considering misalignment of power line armatureD. A. Yaroslavskiy0M. F. Sadykov1A. B. Konov2D. A. Ivanov3M. P. Goryachev4T. G. Yambaeva5Federal state educational institution of higher education "Kazan State Power Engineering University"Federal state educational institution of higher education "Kazan State Power Engineering University"The Kazan E.K. Zavoisky Physical-Technical Institute of the Kazan Scientific Center of the Russian Academy of SciencesFederal state educational institution of higher education "Kazan State Power Engineering University"Federal state educational institution of higher education "Kazan State Power Engineering University"Federal state educational institution of higher education "Kazan State Power Engineering University"One of the most serious causes of accidents in high-power electric power systems is the formation of ice on the wires of high-voltage transmission lines (HVL). In this case, it should be noted that it is necessary to accurately localize the problematic ice area of a site or defect, since it is often difficult to travel along a high-voltage line. In addition, the effect of dragging the wire from one span to the other (misalignment) is observed on worn-out overhead power transmission lines. To solve the set tasks, there was a method for monitoring ice deposits on the overhead lines based on the mathematical model of the chain line, which makes it possible to determine the current sag and elongation of the wire in the span, the force of its tension, taking into account the misalignment of the wires on the line. Implementation of this technique will allow to detect the appearance of ice deposits on the overhead line, which allows timely implementation of measures to prevent emergency situations on the line (optimization of the melting schedule for ice on the wires).https://www.energyret.ru/jour/article/view/386misalignment of wiresmathematical model of a chain linesag wiresice formation |
spellingShingle | D. A. Yaroslavskiy M. F. Sadykov A. B. Konov D. A. Ivanov M. P. Goryachev T. G. Yambaeva Methodology of monitoring ice on wires with considering misalignment of power line armature Известия высших учебных заведений: Проблемы энергетики misalignment of wires mathematical model of a chain line sag wires ice formation |
title | Methodology of monitoring ice on wires with considering misalignment of power line armature |
title_full | Methodology of monitoring ice on wires with considering misalignment of power line armature |
title_fullStr | Methodology of monitoring ice on wires with considering misalignment of power line armature |
title_full_unstemmed | Methodology of monitoring ice on wires with considering misalignment of power line armature |
title_short | Methodology of monitoring ice on wires with considering misalignment of power line armature |
title_sort | methodology of monitoring ice on wires with considering misalignment of power line armature |
topic | misalignment of wires mathematical model of a chain line sag wires ice formation |
url | https://www.energyret.ru/jour/article/view/386 |
work_keys_str_mv | AT dayaroslavskiy methodologyofmonitoringiceonwireswithconsideringmisalignmentofpowerlinearmature AT mfsadykov methodologyofmonitoringiceonwireswithconsideringmisalignmentofpowerlinearmature AT abkonov methodologyofmonitoringiceonwireswithconsideringmisalignmentofpowerlinearmature AT daivanov methodologyofmonitoringiceonwireswithconsideringmisalignmentofpowerlinearmature AT mpgoryachev methodologyofmonitoringiceonwireswithconsideringmisalignmentofpowerlinearmature AT tgyambaeva methodologyofmonitoringiceonwireswithconsideringmisalignmentofpowerlinearmature |