Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected Biomodels

The aim was to evaluate the effectiveness of using the “Sterius 60” microwave disinfection system (Russia) for decontamination of objects infected with PBA of groups I–IV emerging as a result of working with infected laboratory animals.Materials and methods. Effectiveness verification of disinfectio...

Full description

Bibliographic Details
Main Authors: V. G. Germanchuk, A. P. Semakova, O. A. Lobovikova, M. V. Gordeeva, N. Yu. Shavina, K. M. Morozov, Z. L. Devdariani, N. P. Mironova
Format: Article
Language:Russian
Published: Federal Government Health Institution, Russian Research Anti-Plague Institute “Microbe” 2021-02-01
Series:Проблемы особо опасных инфекций
Subjects:
Online Access:https://journal.microbe.ru/jour/article/view/1405
_version_ 1797220807923990528
author V. G. Germanchuk
A. P. Semakova
O. A. Lobovikova
M. V. Gordeeva
N. Yu. Shavina
K. M. Morozov
Z. L. Devdariani
N. P. Mironova
author_facet V. G. Germanchuk
A. P. Semakova
O. A. Lobovikova
M. V. Gordeeva
N. Yu. Shavina
K. M. Morozov
Z. L. Devdariani
N. P. Mironova
author_sort V. G. Germanchuk
collection DOAJ
description The aim was to evaluate the effectiveness of using the “Sterius 60” microwave disinfection system (Russia) for decontamination of objects infected with PBA of groups I–IV emerging as a result of working with infected laboratory animals.Materials and methods. Effectiveness verification of disinfection of biological waste generated as a result of the life of laboratory animals by SHF radiation was carried out in the microwave system “Sterius 60”, recommended by the manufacturer for disinfection of epidemiologically hazardous and extremely dangerous medical waste, including biological ones (classes B and C), by volumetric SHF heating. Carcasses of uninfected laboratory animals (white mice, Guinea pigs, suckling rabbits), granulated feed and bedding material (wood shavings), which are objects directly in contact with biomodels, were used as vivarium waste to be decontaminated. The following microorganisms were utilized as model test ones: Bacillus subtilus VKM B-911, Bacillus stearothermophilus VKM B-718, Bacillus licheniformis G VKM B-1711-D, Alcaligenes faecalis 415, Yersinia pestis EV, Bacillus anthracis STI. Laboratory utensils (plastic Petri dishes, porcelain mortars and pestles) were used as a mock-up chamber filler for model test microorganisms.Results and discussion. As a result of the study, data were obtained indicating that the microwave system for disinfection of medical waste “Sterius 60” is ineffective for decontamination of biological waste in laboratories working with biomodels infected with PBA of groups I–II. The established standard mode of disinfection of this system was effective only for non-spore forms of microorganisms, pathogenicity groups III–IV. Therefore, in our opinion, it is advisable to use it for decontamination of laboratory utensils infected with PBA of groups III–IV, directly at sites of waste generation.
first_indexed 2024-03-08T13:41:24Z
format Article
id doaj.art-7c48d437ae434ca4aae72a250fc240a0
institution Directory Open Access Journal
issn 0370-1069
2658-719X
language Russian
last_indexed 2024-04-24T12:55:25Z
publishDate 2021-02-01
publisher Federal Government Health Institution, Russian Research Anti-Plague Institute “Microbe”
record_format Article
series Проблемы особо опасных инфекций
spelling doaj.art-7c48d437ae434ca4aae72a250fc240a02024-04-05T16:47:15ZrusFederal Government Health Institution, Russian Research Anti-Plague Institute “Microbe”Проблемы особо опасных инфекций0370-10692658-719X2021-02-0104535810.21055/0370-1069-2020-4-53-581244Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected BiomodelsV. G. Germanchuk0A. P. Semakova1O. A. Lobovikova2M. V. Gordeeva3N. Yu. Shavina4K. M. Morozov5Z. L. Devdariani6N. P. Mironova7Russian Research Anti-Plague Institute “Microbe”Russian Research Anti-Plague Institute “Microbe”Russian Research Anti-Plague Institute “Microbe”Russian Research Anti-Plague Institute “Microbe”Russian Research Anti-Plague Institute “Microbe”Russian Research Anti-Plague Institute “Microbe”Russian Research Anti-Plague Institute “Microbe”Russian Research Anti-Plague Institute “Microbe”The aim was to evaluate the effectiveness of using the “Sterius 60” microwave disinfection system (Russia) for decontamination of objects infected with PBA of groups I–IV emerging as a result of working with infected laboratory animals.Materials and methods. Effectiveness verification of disinfection of biological waste generated as a result of the life of laboratory animals by SHF radiation was carried out in the microwave system “Sterius 60”, recommended by the manufacturer for disinfection of epidemiologically hazardous and extremely dangerous medical waste, including biological ones (classes B and C), by volumetric SHF heating. Carcasses of uninfected laboratory animals (white mice, Guinea pigs, suckling rabbits), granulated feed and bedding material (wood shavings), which are objects directly in contact with biomodels, were used as vivarium waste to be decontaminated. The following microorganisms were utilized as model test ones: Bacillus subtilus VKM B-911, Bacillus stearothermophilus VKM B-718, Bacillus licheniformis G VKM B-1711-D, Alcaligenes faecalis 415, Yersinia pestis EV, Bacillus anthracis STI. Laboratory utensils (plastic Petri dishes, porcelain mortars and pestles) were used as a mock-up chamber filler for model test microorganisms.Results and discussion. As a result of the study, data were obtained indicating that the microwave system for disinfection of medical waste “Sterius 60” is ineffective for decontamination of biological waste in laboratories working with biomodels infected with PBA of groups I–II. The established standard mode of disinfection of this system was effective only for non-spore forms of microorganisms, pathogenicity groups III–IV. Therefore, in our opinion, it is advisable to use it for decontamination of laboratory utensils infected with PBA of groups III–IV, directly at sites of waste generation.https://journal.microbe.ru/jour/article/view/1405microwave disinfection system for medical wasteshf radiationbiological wastebiological safetypathogenic biological agents of groups i–ivlaboratory animals
spellingShingle V. G. Germanchuk
A. P. Semakova
O. A. Lobovikova
M. V. Gordeeva
N. Yu. Shavina
K. M. Morozov
Z. L. Devdariani
N. P. Mironova
Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected Biomodels
Проблемы особо опасных инфекций
microwave disinfection system for medical waste
shf radiation
biological waste
biological safety
pathogenic biological agents of groups i–iv
laboratory animals
title Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected Biomodels
title_full Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected Biomodels
title_fullStr Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected Biomodels
title_full_unstemmed Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected Biomodels
title_short Effectiveness of the “Sterius 60” SHF Radiation Installation for Disinfection of Objects Contaminated with PBA of Groups I–IV, when Working with Infected Biomodels
title_sort effectiveness of the sterius 60 shf radiation installation for disinfection of objects contaminated with pba of groups i iv when working with infected biomodels
topic microwave disinfection system for medical waste
shf radiation
biological waste
biological safety
pathogenic biological agents of groups i–iv
laboratory animals
url https://journal.microbe.ru/jour/article/view/1405
work_keys_str_mv AT vggermanchuk effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels
AT apsemakova effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels
AT oalobovikova effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels
AT mvgordeeva effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels
AT nyushavina effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels
AT kmmorozov effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels
AT zldevdariani effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels
AT npmironova effectivenessofthesterius60shfradiationinstallationfordisinfectionofobjectscontaminatedwithpbaofgroupsiivwhenworkingwithinfectedbiomodels