Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma

Purpose: To correlate and analyze the pattern of the visual field (VF) defects by perimetry and anterior chamber angle parameters by AS-OCT in primary angle-closure glaucoma (PACG) across varied severity levels on presentation to a tertiary eye care center. Methods: This was a cross-sectional study,...

Full description

Bibliographic Details
Main Authors: Sreeramyaa Palanisamy, Vidya Raja, Vijayalakshmi A Senthilkumar, Iswarya Mani, R Krishnadas
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2022-01-01
Series:Indian Journal of Ophthalmology
Subjects:
Online Access:http://www.ijo.in/article.asp?issn=0301-4738;year=2022;volume=70;issue=8;spage=2895;epage=2901;aulast=Palanisamy
_version_ 1798038580359069696
author Sreeramyaa Palanisamy
Vidya Raja
Vijayalakshmi A Senthilkumar
Iswarya Mani
R Krishnadas
author_facet Sreeramyaa Palanisamy
Vidya Raja
Vijayalakshmi A Senthilkumar
Iswarya Mani
R Krishnadas
author_sort Sreeramyaa Palanisamy
collection DOAJ
description Purpose: To correlate and analyze the pattern of the visual field (VF) defects by perimetry and anterior chamber angle parameters by AS-OCT in primary angle-closure glaucoma (PACG) across varied severity levels on presentation to a tertiary eye care center. Methods: This was a cross-sectional study, which included 323 eyes of clinically diagnosed cases of PACG. Glaucoma severity was categorized according to mean deviation (MD) as mild (-6.00 dB or more), moderate (-6.01 to -12.00 dB), and severe (-12.01 to -30.00 dB). AS-OCT measured the nasal (N) and temporal (T) angle opening distance at 500 μm (AOD 500) and 750 μm (AOD 750), anterior chamber angle (ACA), lens vault (LV), and anterior chamber width (ACW). The VF severity was then correlated with the AS-OCT parameters using statistical analysis. Results: The mean age ± standard deviation (SD) of the patients included in the study was 56.03 ± 8.6 years, with a 1:1.2 gender ratio. The number of eyes with mild, moderate, and severe VFs were 140 (43.3%), 88 (27.24%), and 95 (29.41%), respectively. There was no statistically significant correlation in the mean anterior chamber angle parameters (AOD 500, AOD 750, ACA 500, ACA 750, LV, ACW, and axial length (AL)) among the groups. However, the correlation between AOD 500 and LV thickness was found to be significant (P = 0.0000) with a negative Spearman's rank correlation coefficient (r = -0.3329). Conclusion: The ACA parameters obtained by AS-OCT along the horizontal axis after elimination of pupillary block by laser peripheral iridotomy do not correlate and cannot be used to assess the disease severity of PACG.
first_indexed 2024-04-11T21:42:08Z
format Article
id doaj.art-7c7fd6eccda840c58fa20c5b02c3c041
institution Directory Open Access Journal
issn 0301-4738
1998-3689
language English
last_indexed 2024-04-11T21:42:08Z
publishDate 2022-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Indian Journal of Ophthalmology
spelling doaj.art-7c7fd6eccda840c58fa20c5b02c3c0412022-12-22T04:01:34ZengWolters Kluwer Medknow PublicationsIndian Journal of Ophthalmology0301-47381998-36892022-01-017082895290110.4103/ijo.IJO_232_22Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucomaSreeramyaa PalanisamyVidya RajaVijayalakshmi A SenthilkumarIswarya ManiR KrishnadasPurpose: To correlate and analyze the pattern of the visual field (VF) defects by perimetry and anterior chamber angle parameters by AS-OCT in primary angle-closure glaucoma (PACG) across varied severity levels on presentation to a tertiary eye care center. Methods: This was a cross-sectional study, which included 323 eyes of clinically diagnosed cases of PACG. Glaucoma severity was categorized according to mean deviation (MD) as mild (-6.00 dB or more), moderate (-6.01 to -12.00 dB), and severe (-12.01 to -30.00 dB). AS-OCT measured the nasal (N) and temporal (T) angle opening distance at 500 μm (AOD 500) and 750 μm (AOD 750), anterior chamber angle (ACA), lens vault (LV), and anterior chamber width (ACW). The VF severity was then correlated with the AS-OCT parameters using statistical analysis. Results: The mean age ± standard deviation (SD) of the patients included in the study was 56.03 ± 8.6 years, with a 1:1.2 gender ratio. The number of eyes with mild, moderate, and severe VFs were 140 (43.3%), 88 (27.24%), and 95 (29.41%), respectively. There was no statistically significant correlation in the mean anterior chamber angle parameters (AOD 500, AOD 750, ACA 500, ACA 750, LV, ACW, and axial length (AL)) among the groups. However, the correlation between AOD 500 and LV thickness was found to be significant (P = 0.0000) with a negative Spearman's rank correlation coefficient (r = -0.3329). Conclusion: The ACA parameters obtained by AS-OCT along the horizontal axis after elimination of pupillary block by laser peripheral iridotomy do not correlate and cannot be used to assess the disease severity of PACG.http://www.ijo.in/article.asp?issn=0301-4738;year=2022;volume=70;issue=8;spage=2895;epage=2901;aulast=Palanisamyanterior chamber angle parametersas-octmean deviationprimary angle-closure glaucomavisual field defects
spellingShingle Sreeramyaa Palanisamy
Vidya Raja
Vijayalakshmi A Senthilkumar
Iswarya Mani
R Krishnadas
Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma
Indian Journal of Ophthalmology
anterior chamber angle parameters
as-oct
mean deviation
primary angle-closure glaucoma
visual field defects
title Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma
title_full Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma
title_fullStr Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma
title_full_unstemmed Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma
title_short Correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle-closure glaucoma
title_sort correlation of pattern of visual field loss by perimetry and anterior chamber angle parameters by anterior segment optical coherence tomography in primary angle closure glaucoma
topic anterior chamber angle parameters
as-oct
mean deviation
primary angle-closure glaucoma
visual field defects
url http://www.ijo.in/article.asp?issn=0301-4738;year=2022;volume=70;issue=8;spage=2895;epage=2901;aulast=Palanisamy
work_keys_str_mv AT sreeramyaapalanisamy correlationofpatternofvisualfieldlossbyperimetryandanteriorchamberangleparametersbyanteriorsegmentopticalcoherencetomographyinprimaryangleclosureglaucoma
AT vidyaraja correlationofpatternofvisualfieldlossbyperimetryandanteriorchamberangleparametersbyanteriorsegmentopticalcoherencetomographyinprimaryangleclosureglaucoma
AT vijayalakshmiasenthilkumar correlationofpatternofvisualfieldlossbyperimetryandanteriorchamberangleparametersbyanteriorsegmentopticalcoherencetomographyinprimaryangleclosureglaucoma
AT iswaryamani correlationofpatternofvisualfieldlossbyperimetryandanteriorchamberangleparametersbyanteriorsegmentopticalcoherencetomographyinprimaryangleclosureglaucoma
AT rkrishnadas correlationofpatternofvisualfieldlossbyperimetryandanteriorchamberangleparametersbyanteriorsegmentopticalcoherencetomographyinprimaryangleclosureglaucoma