COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATE
With the development of intelligent distribution networks and access to distributed energy, the solving the problem of timely and accurate determination of the operating state of the distribution network is an urgent task. Based on an improved analysis of the principle components of the network and...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
NAS of Ukraine, Institute of elecrodynamics
2020-10-01
|
Series: | Технічна електродинаміка |
Subjects: | |
Online Access: | https://techned.org.ua/index.php/techned/article/view/28 |
_version_ | 1818614939084914688 |
---|---|
author | Shiwei Su Yiran You Yu Zou |
author_facet | Shiwei Su Yiran You Yu Zou |
author_sort | Shiwei Su |
collection | DOAJ |
description | With the development of intelligent distribution networks and access to distributed energy, the solving the problem of timely and accurate determination of the operating state of the distribution network is an urgent task. Based on an improved analysis of the principle components of the network and statements of a self-organizing neural network, this article proposes the method to evaluate the operating state of medium- and low-voltage distribution networks. At the first step, the system of evaluating indices of the network is formed by advanced component analysis. The evaluation system is grounded on four aspects, including safety, reliability, quality and economy. Next, the self-organizing neural network is used to identify and clean up the data regarding the operating state of the distribution network. At the next step, the indicators are modeled at all levels; the entropy method is applied to calculate the total weight of all indicators. Then the value of each indicator is found and the weak links of the distribution network are determined. At the final stage, the comprehensive assessment of the real operation of the distribution network in Guangxi province is carried out. As shown, the method can effectively reduce the effect of abnormal data and subjectivity factor on the results of evaluating the state of the distribution network. That confirms the feasibility and practicability of the proposed method. References 22, figures 6, tables 6. |
first_indexed | 2024-12-16T16:25:58Z |
format | Article |
id | doaj.art-7cd5511c6c7542a29b15dbac15115320 |
institution | Directory Open Access Journal |
issn | 1607-7970 2218-1903 |
language | English |
last_indexed | 2024-12-16T16:25:58Z |
publishDate | 2020-10-01 |
publisher | NAS of Ukraine, Institute of elecrodynamics |
record_format | Article |
series | Технічна електродинаміка |
spelling | doaj.art-7cd5511c6c7542a29b15dbac151153202022-12-21T22:24:44ZengNAS of Ukraine, Institute of elecrodynamicsТехнічна електродинаміка1607-79702218-19032020-10-01604704710.15407/techned2020.06.04728COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATEShiwei Su0Yiran You1Yu Zou2China Three Gorges University, Hubei Provincial Key Laboratory for Operation and Control of Cascaded Hydropower Station, Yichang 443002, ChinaChina Three Gorges University, College of Electrical Engineering & New Energy, Yichang 443002, China3Qinzhou Power Supply Bureau of Guangxi Power Grid Co., Ltd., Qinzhou 535000, ChinaWith the development of intelligent distribution networks and access to distributed energy, the solving the problem of timely and accurate determination of the operating state of the distribution network is an urgent task. Based on an improved analysis of the principle components of the network and statements of a self-organizing neural network, this article proposes the method to evaluate the operating state of medium- and low-voltage distribution networks. At the first step, the system of evaluating indices of the network is formed by advanced component analysis. The evaluation system is grounded on four aspects, including safety, reliability, quality and economy. Next, the self-organizing neural network is used to identify and clean up the data regarding the operating state of the distribution network. At the next step, the indicators are modeled at all levels; the entropy method is applied to calculate the total weight of all indicators. Then the value of each indicator is found and the weak links of the distribution network are determined. At the final stage, the comprehensive assessment of the real operation of the distribution network in Guangxi province is carried out. As shown, the method can effectively reduce the effect of abnormal data and subjectivity factor on the results of evaluating the state of the distribution network. That confirms the feasibility and practicability of the proposed method. References 22, figures 6, tables 6.https://techned.org.ua/index.php/techned/article/view/28distribution networkimproved principal component analysisself-organizing neural networkentropy combinationcomprehensive evaluation |
spellingShingle | Shiwei Su Yiran You Yu Zou COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATE Технічна електродинаміка distribution network improved principal component analysis self-organizing neural network entropy combination comprehensive evaluation |
title | COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATE |
title_full | COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATE |
title_fullStr | COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATE |
title_full_unstemmed | COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATE |
title_short | COMPREHENSIVE METHOD FOR EVALUATION OF MEDIUM- AND LOW-VOLTAGE DISTRIBUTION NETWORK OPERATING STATE |
title_sort | comprehensive method for evaluation of medium and low voltage distribution network operating state |
topic | distribution network improved principal component analysis self-organizing neural network entropy combination comprehensive evaluation |
url | https://techned.org.ua/index.php/techned/article/view/28 |
work_keys_str_mv | AT shiweisu comprehensivemethodforevaluationofmediumandlowvoltagedistributionnetworkoperatingstate AT yiranyou comprehensivemethodforevaluationofmediumandlowvoltagedistributionnetworkoperatingstate AT yuzou comprehensivemethodforevaluationofmediumandlowvoltagedistributionnetworkoperatingstate |