Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant

The aim of this paper is to compare von Mises stress levels and displacements between two possible designs of a class II Kennedy unilateral removable partial denture. Finite element analysis was used to compare two unilateral class II Kennedy removable partial dentures replacing a mandibular second...

Full description

Bibliographic Details
Main Authors: Oana Cella Andrei, Livia Alice Tănăsescu, Ioana Daniela Tărlungeanu, Magdalena Natalia Dina, Mircea Horia Tierean
Format: Article
Language:English
Published: MDPI AG 2022-05-01
Series:Applied Sciences
Subjects:
Online Access:https://www.mdpi.com/2076-3417/12/10/5116
_version_ 1797501779879919616
author Oana Cella Andrei
Livia Alice Tănăsescu
Ioana Daniela Tărlungeanu
Magdalena Natalia Dina
Mircea Horia Tierean
author_facet Oana Cella Andrei
Livia Alice Tănăsescu
Ioana Daniela Tărlungeanu
Magdalena Natalia Dina
Mircea Horia Tierean
author_sort Oana Cella Andrei
collection DOAJ
description The aim of this paper is to compare von Mises stress levels and displacements between two possible designs of a class II Kennedy unilateral removable partial denture. Finite element analysis was used to compare two unilateral class II Kennedy removable partial dentures replacing a mandibular second premolar, and first and second molars and with the same design, except a distal implant. The 3D model was created for a mandibular RPD with three artificial teeth and double ball attachment on the abutment teeth and a horizontal ball attachment for the implant, using Autodesk Inventor 2022 software. On the saddle, significant differences appear only when force is applied on the second molar. Association with implant increases von Mises stresses on the acrylic saddle, where displacements values are similar, and decreases von Mises stresses on the muco-osseous support, where displacements values are also similar. Regarding metal reinforcement of the denture, von Mises stress values are greater for forces applied on the second premolar in the implant situation, and smaller for forces applied on the first and second molars. Association with implant decreases von Mises stresses on the metal reinforcement of the denture only if the force is applied distally, on the two molars; in this case, the metal reinforcement is more stressed above the mesial double ball attachment, where displacements values are similar. Regarding the artificial teeth, adding a distal implant does not significantly influence the stress and displacements values, except on the second premolar where the von Mises stresses values are greater, where displacements values are similar. Although an association with an implant increases the risk of fracture for the denture, the results demonstrate that in the posterior area of the edentulous space, the denture exerts less pressure on the mucosa and subjacent bone, protecting the area against resorption.
first_indexed 2024-03-10T03:23:28Z
format Article
id doaj.art-7d3547c02dc54177b45ab9ceaa007f5e
institution Directory Open Access Journal
issn 2076-3417
language English
last_indexed 2024-03-10T03:23:28Z
publishDate 2022-05-01
publisher MDPI AG
record_format Article
series Applied Sciences
spelling doaj.art-7d3547c02dc54177b45ab9ceaa007f5e2023-11-23T09:57:56ZengMDPI AGApplied Sciences2076-34172022-05-011210511610.3390/app12105116Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal ImplantOana Cella Andrei0Livia Alice Tănăsescu1Ioana Daniela Tărlungeanu2Magdalena Natalia Dina3Mircea Horia Tierean4Department of Removable Prosthodontics, Faculty of Dentistry, University of Medicine and Pharmacy “Carol Davila” Bucharest, 37 Dionisie Lupu Street, 020021 Bucharest, RomaniaDepartment of Removable Prosthodontics, Faculty of Dentistry, University of Medicine and Pharmacy “Carol Davila” Bucharest, 37 Dionisie Lupu Street, 020021 Bucharest, RomaniaDepartment of Removable Prosthodontics, Faculty of Dentistry, University of Medicine and Pharmacy “Carol Davila” Bucharest, 37 Dionisie Lupu Street, 020021 Bucharest, RomaniaDepartment of Dental Techniques, Faculty of Midwifery and Nursing, University of Medicine and Pharmacy “Carol Davila” Bucharest, 37 Dionisie Lupu Street, 020021 Bucharest, RomaniaMaterials Engineering and Welding Department, Transilvania University of Brasov, 29 Eroilor Blvd., 500036 Brasov, RomaniaThe aim of this paper is to compare von Mises stress levels and displacements between two possible designs of a class II Kennedy unilateral removable partial denture. Finite element analysis was used to compare two unilateral class II Kennedy removable partial dentures replacing a mandibular second premolar, and first and second molars and with the same design, except a distal implant. The 3D model was created for a mandibular RPD with three artificial teeth and double ball attachment on the abutment teeth and a horizontal ball attachment for the implant, using Autodesk Inventor 2022 software. On the saddle, significant differences appear only when force is applied on the second molar. Association with implant increases von Mises stresses on the acrylic saddle, where displacements values are similar, and decreases von Mises stresses on the muco-osseous support, where displacements values are also similar. Regarding metal reinforcement of the denture, von Mises stress values are greater for forces applied on the second premolar in the implant situation, and smaller for forces applied on the first and second molars. Association with implant decreases von Mises stresses on the metal reinforcement of the denture only if the force is applied distally, on the two molars; in this case, the metal reinforcement is more stressed above the mesial double ball attachment, where displacements values are similar. Regarding the artificial teeth, adding a distal implant does not significantly influence the stress and displacements values, except on the second premolar where the von Mises stresses values are greater, where displacements values are similar. Although an association with an implant increases the risk of fracture for the denture, the results demonstrate that in the posterior area of the edentulous space, the denture exerts less pressure on the mucosa and subjacent bone, protecting the area against resorption.https://www.mdpi.com/2076-3417/12/10/5116unilateral removable partial denturedental implantfinite element analysis
spellingShingle Oana Cella Andrei
Livia Alice Tănăsescu
Ioana Daniela Tărlungeanu
Magdalena Natalia Dina
Mircea Horia Tierean
Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant
Applied Sciences
unilateral removable partial denture
dental implant
finite element analysis
title Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant
title_full Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant
title_fullStr Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant
title_full_unstemmed Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant
title_short Finite Element Comparative Analysis of Von Mises Stress Levels in Unilateral Removable Partial Denture with and without Distal Implant
title_sort finite element comparative analysis of von mises stress levels in unilateral removable partial denture with and without distal implant
topic unilateral removable partial denture
dental implant
finite element analysis
url https://www.mdpi.com/2076-3417/12/10/5116
work_keys_str_mv AT oanacellaandrei finiteelementcomparativeanalysisofvonmisesstresslevelsinunilateralremovablepartialdenturewithandwithoutdistalimplant
AT liviaalicetanasescu finiteelementcomparativeanalysisofvonmisesstresslevelsinunilateralremovablepartialdenturewithandwithoutdistalimplant
AT ioanadanielatarlungeanu finiteelementcomparativeanalysisofvonmisesstresslevelsinunilateralremovablepartialdenturewithandwithoutdistalimplant
AT magdalenanataliadina finiteelementcomparativeanalysisofvonmisesstresslevelsinunilateralremovablepartialdenturewithandwithoutdistalimplant
AT mirceahoriatierean finiteelementcomparativeanalysisofvonmisesstresslevelsinunilateralremovablepartialdenturewithandwithoutdistalimplant