Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique

Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μ...

Full description

Bibliographic Details
Main Authors: Karina Bergamo Cardoso, Edmara Tatiely Pedroso Bergamo, Vitor De Moraes Cruz, Ilana Santos Ramalho, Lucas Fracassi De Oliveira Lino, Estevam Augusto Bonfante
Format: Article
Language:English
Published: University of São Paulo
Series:Journal of Applied Oral Science
Subjects:
Online Access:http://www.scielo.br/pdf/jaos/v28/1678-7765-jaos-28-e20200343.pdf
_version_ 1819180119350050816
author Karina Bergamo Cardoso
Edmara Tatiely Pedroso Bergamo
Vitor De Moraes Cruz
Ilana Santos Ramalho
Lucas Fracassi De Oliveira Lino
Estevam Augusto Bonfante
author_facet Karina Bergamo Cardoso
Edmara Tatiely Pedroso Bergamo
Vitor De Moraes Cruz
Ilana Santos Ramalho
Lucas Fracassi De Oliveira Lino
Estevam Augusto Bonfante
author_sort Karina Bergamo Cardoso
collection DOAJ
description Abstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. Conclusion: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.
first_indexed 2024-12-22T22:09:16Z
format Article
id doaj.art-7d50e85d98384d70b6bb733daefaa851
institution Directory Open Access Journal
issn 1678-7765
language English
last_indexed 2024-12-22T22:09:16Z
publisher University of São Paulo
record_format Article
series Journal of Applied Oral Science
spelling doaj.art-7d50e85d98384d70b6bb733daefaa8512022-12-21T18:10:55ZengUniversity of São PauloJournal of Applied Oral Science1678-776510.1590/1678-7757-2020-0343Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica techniqueKarina Bergamo CardosoEdmara Tatiely Pedroso BergamoVitor De Moraes CruzIlana Santos RamalhoLucas Fracassi De Oliveira LinoEstevam Augusto BonfanteAbstract An important factor affecting the biomechanical behavior of implant-supported reconstructions is the implant-abutment misfit. Objective: This study evaluated the misfit between Ti-Base abutments and implants by means of polyvinyl siloxane replica technique using microcomputed tomography (μCT). Methodology: Volumetric and linear (central and marginal) gaps of four Ti-base abutments (n=10/group): (i) Odontofix LTDA (OD), (ii) Singular Implants (SING), (iii) EFF Dental Components (EFF), and (iv) Control Group (S.I.N implants) compatible with an implant system (Strong SW, S.I.N Implants) were measured using μCT reconstructed polyvinyl siloxane replicas. Results: The results showed significantly lower volume gap for Control S.I.N (0.67±0.29 mm3) and SING (0.69±0.28 mm3) Ti-base abutments relative to OD (1.42±0.28 mm3) and EFF groups (1.04±0.28 mm3) (p<0.033), without significant difference between them (p=0.936). While gap values were homogenous in the central region, EFF presented a significantly higher marginal gap. Accordingly, the Control S.I.N and Singular Ti-base abutments showed improved volumetric and marginal fit relative to Odontofix and EFF. Conclusion: The method of manufacturing abutments influenced the misfit at the implant-abutment interface.http://www.scielo.br/pdf/jaos/v28/1678-7765-jaos-28-e20200343.pdfDental implantsDental abutmentsX-ray microtomography
spellingShingle Karina Bergamo Cardoso
Edmara Tatiely Pedroso Bergamo
Vitor De Moraes Cruz
Ilana Santos Ramalho
Lucas Fracassi De Oliveira Lino
Estevam Augusto Bonfante
Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique
Journal of Applied Oral Science
Dental implants
Dental abutments
X-ray microtomography
title Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique
title_full Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique
title_fullStr Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique
title_full_unstemmed Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique
title_short Three-dimensional misfit between Ti-Base abutments and implants evaluated by replica technique
title_sort three dimensional misfit between ti base abutments and implants evaluated by replica technique
topic Dental implants
Dental abutments
X-ray microtomography
url http://www.scielo.br/pdf/jaos/v28/1678-7765-jaos-28-e20200343.pdf
work_keys_str_mv AT karinabergamocardoso threedimensionalmisfitbetweentibaseabutmentsandimplantsevaluatedbyreplicatechnique
AT edmaratatielypedrosobergamo threedimensionalmisfitbetweentibaseabutmentsandimplantsevaluatedbyreplicatechnique
AT vitordemoraescruz threedimensionalmisfitbetweentibaseabutmentsandimplantsevaluatedbyreplicatechnique
AT ilanasantosramalho threedimensionalmisfitbetweentibaseabutmentsandimplantsevaluatedbyreplicatechnique
AT lucasfracassideoliveiralino threedimensionalmisfitbetweentibaseabutmentsandimplantsevaluatedbyreplicatechnique
AT estevamaugustobonfante threedimensionalmisfitbetweentibaseabutmentsandimplantsevaluatedbyreplicatechnique