Damage grading system for severity assessment on concrete structure

Acoustic Emission (AE) is a high frequency stress wave generated by rapid release of energy in solid material due to changes such as crack initiation and growth. High sensitivity to crack growth, the ability to locate the source, its passive nature and the possibility to perform real-time monitoring...

Full description

Bibliographic Details
Main Authors: Shahiron Shahidan, Sharifah Salwa Mohd Zuki, Norwati Jamaluddin
Format: Article
Language:English
Published: Elsevier 2016-12-01
Series:Case Studies in Construction Materials
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214509516300535
_version_ 1811344251609415680
author Shahiron Shahidan
Sharifah Salwa Mohd Zuki
Norwati Jamaluddin
author_facet Shahiron Shahidan
Sharifah Salwa Mohd Zuki
Norwati Jamaluddin
author_sort Shahiron Shahidan
collection DOAJ
description Acoustic Emission (AE) is a high frequency stress wave generated by rapid release of energy in solid material due to changes such as crack initiation and growth. High sensitivity to crack growth, the ability to locate the source, its passive nature and the possibility to perform real-time monitoring are some of the attractive features of the AE technique. In spite of these advantages, challenges still exist in using the AE technique for monitoring applications, especially in the analysis of recorded AE data as large volume of data are usually generated during the monitoring process. The need for effective data analysis in a grading system can be linked to the main objective of this research; to develop a new standard grading system for severity assessment. In this research, the cyclic load test (CLT) method is the first method used for this evaluation system. This is a relatively new method that may provide better insights into structural integrity and also collaborates with the AE evaluation system. This study proposed and tested the absolute energy parameter in the evaluation for determining the damage level in Reinforced concrete RC structure. The Intensity Absolute Energy Analysis (IAEA) methods that involved the absolute energy parameter were investigated to determine the damage level in RC structure. This was found to provide encouraging results for the analysis of AE data parameters in determining the damage grading system. By addressing this primary issue, it is believed that this study can help improve the effectiveness of the AE technique for Structural Health Monitoring (SHM) in civil engineering.
first_indexed 2024-04-13T19:44:30Z
format Article
id doaj.art-7dd54617b0e84f20b44930829f8a798f
institution Directory Open Access Journal
issn 2214-5095
language English
last_indexed 2024-04-13T19:44:30Z
publishDate 2016-12-01
publisher Elsevier
record_format Article
series Case Studies in Construction Materials
spelling doaj.art-7dd54617b0e84f20b44930829f8a798f2022-12-22T02:32:46ZengElsevierCase Studies in Construction Materials2214-50952016-12-015C798610.1016/j.cscm.2016.09.001Damage grading system for severity assessment on concrete structureShahiron ShahidanSharifah Salwa Mohd ZukiNorwati JamaluddinAcoustic Emission (AE) is a high frequency stress wave generated by rapid release of energy in solid material due to changes such as crack initiation and growth. High sensitivity to crack growth, the ability to locate the source, its passive nature and the possibility to perform real-time monitoring are some of the attractive features of the AE technique. In spite of these advantages, challenges still exist in using the AE technique for monitoring applications, especially in the analysis of recorded AE data as large volume of data are usually generated during the monitoring process. The need for effective data analysis in a grading system can be linked to the main objective of this research; to develop a new standard grading system for severity assessment. In this research, the cyclic load test (CLT) method is the first method used for this evaluation system. This is a relatively new method that may provide better insights into structural integrity and also collaborates with the AE evaluation system. This study proposed and tested the absolute energy parameter in the evaluation for determining the damage level in Reinforced concrete RC structure. The Intensity Absolute Energy Analysis (IAEA) methods that involved the absolute energy parameter were investigated to determine the damage level in RC structure. This was found to provide encouraging results for the analysis of AE data parameters in determining the damage grading system. By addressing this primary issue, it is believed that this study can help improve the effectiveness of the AE technique for Structural Health Monitoring (SHM) in civil engineering.http://www.sciencedirect.com/science/article/pii/S2214509516300535Abs energyConcreteAcoustic emissionAssessmentGrading system
spellingShingle Shahiron Shahidan
Sharifah Salwa Mohd Zuki
Norwati Jamaluddin
Damage grading system for severity assessment on concrete structure
Case Studies in Construction Materials
Abs energy
Concrete
Acoustic emission
Assessment
Grading system
title Damage grading system for severity assessment on concrete structure
title_full Damage grading system for severity assessment on concrete structure
title_fullStr Damage grading system for severity assessment on concrete structure
title_full_unstemmed Damage grading system for severity assessment on concrete structure
title_short Damage grading system for severity assessment on concrete structure
title_sort damage grading system for severity assessment on concrete structure
topic Abs energy
Concrete
Acoustic emission
Assessment
Grading system
url http://www.sciencedirect.com/science/article/pii/S2214509516300535
work_keys_str_mv AT shahironshahidan damagegradingsystemforseverityassessmentonconcretestructure
AT sharifahsalwamohdzuki damagegradingsystemforseverityassessmentonconcretestructure
AT norwatijamaluddin damagegradingsystemforseverityassessmentonconcretestructure