Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement

Background/Aim. Reconstruction of lost, damaged or distorted mandibular bone presents a challenge from the functional side, as well as from the esthetic point of view. The aim of this study was to determinate potential differences between values of the basic linear moprhometric parameters (LMPs) obt...

Full description

Bibliographic Details
Main Authors: Arsić Stojanka, Perić Predrag, Stojković Miloš, Ilić Dragana, Stojanović Miodrag, Ajduković Zorica, Vučić Strahinja
Format: Article
Language:English
Published: Military Health Department, Ministry of Defance, Serbia 2010-01-01
Series:Vojnosanitetski Pregled
Subjects:
Online Access:http://www.doiserbia.nb.rs/img/doi/0042-8450/2010/0042-84501010839A.pdf
_version_ 1818540190809980928
author Arsić Stojanka
Perić Predrag
Stojković Miloš
Ilić Dragana
Stojanović Miodrag
Ajduković Zorica
Vučić Strahinja
author_facet Arsić Stojanka
Perić Predrag
Stojković Miloš
Ilić Dragana
Stojanović Miodrag
Ajduković Zorica
Vučić Strahinja
author_sort Arsić Stojanka
collection DOAJ
description Background/Aim. Reconstruction of lost, damaged or distorted mandibular bone presents a challenge from the functional side, as well as from the esthetic point of view. The aim of this study was to determinate potential differences between values of the basic linear moprhometric parameters (LMPs) obtained by direct and indirect manual measurement of the same humane mandibles, with accuracy testing of indirect measurement, which are routinely used in every-day clinical practice. The results are essential for defining of parametric model of the 'standard mandible' and virtual modeling of the humane mandible in future researches as well as in clinical medicine. Methods. A total number of 12 dry bony mandibles of human adults were studied. According to the standard anatomical landmarks, 10 standard LPMs were measured on each mandible by different manual methods: directly by a sliding caliper with nonius, and indirectly using standard software on two-dimensional (2D) reconstructions of mandibular multislice computed tomography (MSCT) scans. The values obtained by the different measuring methods were matched for the same LMPs. Results. Statistically significant differences between compared LMPs values obtained by different measuring methods, appeared in the gnathio-interdental distance (Gn-IdD), as well as in the gnathio-condylar distance (Gn-CoD), bilaterally. In both parameters, significantly higher mean values (with percent of difference) were obtained by direct versus indirect measurement: Gn-IdD (21.57%; 29.2 mm vs 22.9 mm; p = 0.004); Gn-CoD left side (14.1%; 122.7 mm vs 105.4 cm; p = 0.001); Gn-CoD right side (11.87%; 124.7 mm vs 109.9 mm; p = 0.009). Conclusion. According to the observed inaccuracy of indirect measurement, we recommended the use of a correction factor for calculation of both Gn-IdD and Gn-CoD real vales, in defining of parametric model of the 'standard mandible' based on indirect morphometry on 2D reconstructions of mandibular MSCT scans. Additional studies with larger number of specimens and quantification of anatomical variations regarding to sex, age, dentition status and ethnic origin, additionally should increase measurement accuracy and consequently reliability of future parametric model of the human mandible.
first_indexed 2024-12-11T21:52:03Z
format Article
id doaj.art-7dec08d042684d21bf601143b231c3ec
institution Directory Open Access Journal
issn 0042-8450
language English
last_indexed 2024-12-11T21:52:03Z
publishDate 2010-01-01
publisher Military Health Department, Ministry of Defance, Serbia
record_format Article
series Vojnosanitetski Pregled
spelling doaj.art-7dec08d042684d21bf601143b231c3ec2022-12-22T00:49:25ZengMilitary Health Department, Ministry of Defance, SerbiaVojnosanitetski Pregled0042-84502010-01-01671083984610.2298/VSP1010839AComparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurementArsić StojankaPerić PredragStojković MilošIlić DraganaStojanović MiodragAjduković ZoricaVučić StrahinjaBackground/Aim. Reconstruction of lost, damaged or distorted mandibular bone presents a challenge from the functional side, as well as from the esthetic point of view. The aim of this study was to determinate potential differences between values of the basic linear moprhometric parameters (LMPs) obtained by direct and indirect manual measurement of the same humane mandibles, with accuracy testing of indirect measurement, which are routinely used in every-day clinical practice. The results are essential for defining of parametric model of the 'standard mandible' and virtual modeling of the humane mandible in future researches as well as in clinical medicine. Methods. A total number of 12 dry bony mandibles of human adults were studied. According to the standard anatomical landmarks, 10 standard LPMs were measured on each mandible by different manual methods: directly by a sliding caliper with nonius, and indirectly using standard software on two-dimensional (2D) reconstructions of mandibular multislice computed tomography (MSCT) scans. The values obtained by the different measuring methods were matched for the same LMPs. Results. Statistically significant differences between compared LMPs values obtained by different measuring methods, appeared in the gnathio-interdental distance (Gn-IdD), as well as in the gnathio-condylar distance (Gn-CoD), bilaterally. In both parameters, significantly higher mean values (with percent of difference) were obtained by direct versus indirect measurement: Gn-IdD (21.57%; 29.2 mm vs 22.9 mm; p = 0.004); Gn-CoD left side (14.1%; 122.7 mm vs 105.4 cm; p = 0.001); Gn-CoD right side (11.87%; 124.7 mm vs 109.9 mm; p = 0.009). Conclusion. According to the observed inaccuracy of indirect measurement, we recommended the use of a correction factor for calculation of both Gn-IdD and Gn-CoD real vales, in defining of parametric model of the 'standard mandible' based on indirect morphometry on 2D reconstructions of mandibular MSCT scans. Additional studies with larger number of specimens and quantification of anatomical variations regarding to sex, age, dentition status and ethnic origin, additionally should increase measurement accuracy and consequently reliability of future parametric model of the human mandible.http://www.doiserbia.nb.rs/img/doi/0042-8450/2010/0042-84501010839A.pdfmandiblehumanstomography scanners, x-ray computedsensitivity and specificity
spellingShingle Arsić Stojanka
Perić Predrag
Stojković Miloš
Ilić Dragana
Stojanović Miodrag
Ajduković Zorica
Vučić Strahinja
Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement
Vojnosanitetski Pregled
mandible
humans
tomography scanners, x-ray computed
sensitivity and specificity
title Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement
title_full Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement
title_fullStr Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement
title_full_unstemmed Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement
title_short Comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement
title_sort comparative analysis of linear morphometric parameters of the humane mandibula obtained by direct and indirect measurement
topic mandible
humans
tomography scanners, x-ray computed
sensitivity and specificity
url http://www.doiserbia.nb.rs/img/doi/0042-8450/2010/0042-84501010839A.pdf
work_keys_str_mv AT arsicstojanka comparativeanalysisoflinearmorphometricparametersofthehumanemandibulaobtainedbydirectandindirectmeasurement
AT pericpredrag comparativeanalysisoflinearmorphometricparametersofthehumanemandibulaobtainedbydirectandindirectmeasurement
AT stojkovicmilos comparativeanalysisoflinearmorphometricparametersofthehumanemandibulaobtainedbydirectandindirectmeasurement
AT ilicdragana comparativeanalysisoflinearmorphometricparametersofthehumanemandibulaobtainedbydirectandindirectmeasurement
AT stojanovicmiodrag comparativeanalysisoflinearmorphometricparametersofthehumanemandibulaobtainedbydirectandindirectmeasurement
AT ajdukoviczorica comparativeanalysisoflinearmorphometricparametersofthehumanemandibulaobtainedbydirectandindirectmeasurement
AT vucicstrahinja comparativeanalysisoflinearmorphometricparametersofthehumanemandibulaobtainedbydirectandindirectmeasurement