REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433

The Texas Instruments microcontrollers in the MSP 430 series offer four ways to save power in operation in such a way as to allow for consistent reduction of the electricity consumed. Code Composer Studio programming environment also provides support in making low-power applications. In addition to...

Full description

Bibliographic Details
Main Authors: DAN ROTAR, DRAGOS-ALEXANDRU ANDRIOAIA
Format: Article
Language:English
Published: Alma Mater Publishing House "Vasile Alecsandri" University of Bacau 2022-01-01
Series:Journal of Engineering Studies and Research
Subjects:
Online Access:http://www.jesr.ub.ro/1/article/view/291
_version_ 1818913744518905856
author DAN ROTAR
DRAGOS-ALEXANDRU ANDRIOAIA
author_facet DAN ROTAR
DRAGOS-ALEXANDRU ANDRIOAIA
author_sort DAN ROTAR
collection DOAJ
description The Texas Instruments microcontrollers in the MSP 430 series offer four ways to save power in operation in such a way as to allow for consistent reduction of the electricity consumed. Code Composer Studio programming environment also provides support in making low-power applications. In addition to these, the MSP430FR2433 microcontroller with ferroelectric RAM allows data to be stored even in the absence of power voltage. In view of these properties of the microcontroller, a data logger application has been developed to monitor the quality of the environment in a building. Given that the MSP430FR2433 microcontroller can process both analog and numerical signals, the device monitors the temperature, humidity, carbon dioxide concentration and amount of light present in the enclosure. Thanks to energy-saving mechanisms and the possibility of keeping information for an indefinite period without the need for energy consumption, the ambient quality monitoring device can operate for a long time in places without energy resources. The device has also been tested with good results for autonomous operation using solar energy and has also been used to determine the energy performance of buildings.
first_indexed 2024-12-19T23:35:21Z
format Article
id doaj.art-7ee0bcd3075e44e8ba4539f97bca426e
institution Directory Open Access Journal
issn 2068-7559
2344-4932
language English
last_indexed 2024-12-19T23:35:21Z
publishDate 2022-01-01
publisher Alma Mater Publishing House "Vasile Alecsandri" University of Bacau
record_format Article
series Journal of Engineering Studies and Research
spelling doaj.art-7ee0bcd3075e44e8ba4539f97bca426e2022-12-21T20:01:37ZengAlma Mater Publishing House "Vasile Alecsandri" University of BacauJournal of Engineering Studies and Research2068-75592344-49322022-01-01273REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433DAN ROTARDRAGOS-ALEXANDRU ANDRIOAIA The Texas Instruments microcontrollers in the MSP 430 series offer four ways to save power in operation in such a way as to allow for consistent reduction of the electricity consumed. Code Composer Studio programming environment also provides support in making low-power applications. In addition to these, the MSP430FR2433 microcontroller with ferroelectric RAM allows data to be stored even in the absence of power voltage. In view of these properties of the microcontroller, a data logger application has been developed to monitor the quality of the environment in a building. Given that the MSP430FR2433 microcontroller can process both analog and numerical signals, the device monitors the temperature, humidity, carbon dioxide concentration and amount of light present in the enclosure. Thanks to energy-saving mechanisms and the possibility of keeping information for an indefinite period without the need for energy consumption, the ambient quality monitoring device can operate for a long time in places without energy resources. The device has also been tested with good results for autonomous operation using solar energy and has also been used to determine the energy performance of buildings. http://www.jesr.ub.ro/1/article/view/291msp430 microcontroller, energy consumption, data recorder, ultra-low power, ferroelectric ram, power management, disruption management
spellingShingle DAN ROTAR
DRAGOS-ALEXANDRU ANDRIOAIA
REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433
Journal of Engineering Studies and Research
msp430 microcontroller, energy consumption, data recorder, ultra-low power, ferroelectric ram, power management, disruption management
title REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433
title_full REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433
title_fullStr REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433
title_full_unstemmed REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433
title_short REDUCING THE ENERGY CONSUMPTION OF SYSTEMS WITH THE INTEGRATED CIRCUIT TI 430FR2433
title_sort reducing the energy consumption of systems with the integrated circuit ti 430fr2433
topic msp430 microcontroller, energy consumption, data recorder, ultra-low power, ferroelectric ram, power management, disruption management
url http://www.jesr.ub.ro/1/article/view/291
work_keys_str_mv AT danrotar reducingtheenergyconsumptionofsystemswiththeintegratedcircuitti430fr2433
AT dragosalexandruandrioaia reducingtheenergyconsumptionofsystemswiththeintegratedcircuitti430fr2433