Coherent Beam-forming Combined with Wiener Filter in Ultrasound Imaging
The traditional ultrasonic dynamic focusing imaging which simply uses the delay-and-sum method in beamforming shows low resolution and poor contrast. In this study, based on the coherent pixel-based beamforming (Coherent PB), a novel Wiener pre-filter with high computational efficiency is applied to...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Editorial Office of Computerized Tomography Theory and Application
2022-12-01
|
Series: | CT Lilun yu yingyong yanjiu |
Subjects: | |
Online Access: | https://www.cttacn.org.cn/cn/article/doi/10.15953/j.ctta.2022.043 |
_version_ | 1797776514556624896 |
---|---|
author | Sulan PU Huiwen XIE Hao GUO Ping ZHOU Guangquan ZHOU |
author_facet | Sulan PU Huiwen XIE Hao GUO Ping ZHOU Guangquan ZHOU |
author_sort | Sulan PU |
collection | DOAJ |
description | The traditional ultrasonic dynamic focusing imaging which simply uses the delay-and-sum method in beamforming shows low resolution and poor contrast. In this study, based on the coherent pixel-based beamforming (Coherent PB), a novel Wiener pre-filter with high computational efficiency is applied to correct the phase of the entire array signal by using the pulse-echo at the focal point. We also apply a Wiener post-filter calculating adaptive weights for the beamforming results of each sub-aperture to suppress the noise and artifacts. The proposed method's effectiveness is verified through simulation experiments, phantom experiments, and in vivo experiments. Compared with Coherent PB, the proposed method significantly improves the axial resolution and contrast of images while maintaining the high lateral resolution and computational efficiency, which shows certain clinical application value. |
first_indexed | 2024-03-12T22:51:07Z |
format | Article |
id | doaj.art-7f03885b05f841ffa71e9f31104b2ab9 |
institution | Directory Open Access Journal |
issn | 1004-4140 |
language | English |
last_indexed | 2024-03-12T22:51:07Z |
publishDate | 2022-12-01 |
publisher | Editorial Office of Computerized Tomography Theory and Application |
record_format | Article |
series | CT Lilun yu yingyong yanjiu |
spelling | doaj.art-7f03885b05f841ffa71e9f31104b2ab92023-07-20T08:59:34ZengEditorial Office of Computerized Tomography Theory and ApplicationCT Lilun yu yingyong yanjiu1004-41402022-12-0131679380810.15953/j.ctta.2022.0432022.043Coherent Beam-forming Combined with Wiener Filter in Ultrasound ImagingSulan PU0Huiwen XIE1Hao GUO2Ping ZHOU3Guangquan ZHOU4School of Biological Science and Medical Engineering, Southeast University, Nanjing 210008, ChinaSchool of Biological Science and Medical Engineering, Southeast University, Nanjing 210008, ChinaSchool of Biological Science and Medical Engineering, Southeast University, Nanjing 210008, ChinaSchool of Biological Science and Medical Engineering, Southeast University, Nanjing 210008, ChinaSchool of Biological Science and Medical Engineering, Southeast University, Nanjing 210008, ChinaThe traditional ultrasonic dynamic focusing imaging which simply uses the delay-and-sum method in beamforming shows low resolution and poor contrast. In this study, based on the coherent pixel-based beamforming (Coherent PB), a novel Wiener pre-filter with high computational efficiency is applied to correct the phase of the entire array signal by using the pulse-echo at the focal point. We also apply a Wiener post-filter calculating adaptive weights for the beamforming results of each sub-aperture to suppress the noise and artifacts. The proposed method's effectiveness is verified through simulation experiments, phantom experiments, and in vivo experiments. Compared with Coherent PB, the proposed method significantly improves the axial resolution and contrast of images while maintaining the high lateral resolution and computational efficiency, which shows certain clinical application value.https://www.cttacn.org.cn/cn/article/doi/10.15953/j.ctta.2022.043ultrasound beamformingcoherentwiener filteraxial resolution |
spellingShingle | Sulan PU Huiwen XIE Hao GUO Ping ZHOU Guangquan ZHOU Coherent Beam-forming Combined with Wiener Filter in Ultrasound Imaging CT Lilun yu yingyong yanjiu ultrasound beamforming coherent wiener filter axial resolution |
title | Coherent Beam-forming Combined with Wiener Filter in Ultrasound Imaging |
title_full | Coherent Beam-forming Combined with Wiener Filter in Ultrasound Imaging |
title_fullStr | Coherent Beam-forming Combined with Wiener Filter in Ultrasound Imaging |
title_full_unstemmed | Coherent Beam-forming Combined with Wiener Filter in Ultrasound Imaging |
title_short | Coherent Beam-forming Combined with Wiener Filter in Ultrasound Imaging |
title_sort | coherent beam forming combined with wiener filter in ultrasound imaging |
topic | ultrasound beamforming coherent wiener filter axial resolution |
url | https://www.cttacn.org.cn/cn/article/doi/10.15953/j.ctta.2022.043 |
work_keys_str_mv | AT sulanpu coherentbeamformingcombinedwithwienerfilterinultrasoundimaging AT huiwenxie coherentbeamformingcombinedwithwienerfilterinultrasoundimaging AT haoguo coherentbeamformingcombinedwithwienerfilterinultrasoundimaging AT pingzhou coherentbeamformingcombinedwithwienerfilterinultrasoundimaging AT guangquanzhou coherentbeamformingcombinedwithwienerfilterinultrasoundimaging |