Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature

Solar-driven ammonia-water absorption refrigeration system (AARS) has been considered as an alternative for the conventional refrigeration and air-conditioning systems. However, its high initial cost seems to be the main problem that postpones its wide spread use. In the present study, a single-stag...

Full description

Bibliographic Details
Main Authors: Osman Wageiallah Mohammed, Guo Yanling
Format: Article
Language:English
Published: MDPI AG 2017-10-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/10/11/1746
_version_ 1798004040147140608
author Osman Wageiallah Mohammed
Guo Yanling
author_facet Osman Wageiallah Mohammed
Guo Yanling
author_sort Osman Wageiallah Mohammed
collection DOAJ
description Solar-driven ammonia-water absorption refrigeration system (AARS) has been considered as an alternative for the conventional refrigeration and air-conditioning systems. However, its high initial cost seems to be the main problem that postpones its wide spread use. In the present study, a single-stage NH3/H2O ARS is analyzed in depth on the basis of energetic and exergetic coefficients of performance (COP and ECOP, respectively) to decrease its cut in/off temperature. This study was carried out to lower the required heat source temperature, so that a less-expensive solar collector could be used. Effects of all parameters that could influence the system’s performance and cut in/off temperature were investigated in detail. Presence of water in the refrigerant and evaporator temperature glide was considered. Results revealed that appropriate selection of system’s working condition can effectively reduce the driving temperature. Besides, the cut in/off temperature can be significantly decreased by inserting an effective solution heat exchanger (SHX). Required driving temperature can be lowered by up to 10 °C using SHX with 0.80 effectiveness. The results also showed that effects of water content in the refrigerant could not be neglected in studying NH3/H2O ARS because it affects both COP and ECOP. Additionally, a large temperature glide in the evaporator can substantially decrease the ECOP.
first_indexed 2024-04-11T12:17:07Z
format Article
id doaj.art-7f07b0eedc8a44a79bdf9bc99af02786
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-11T12:17:07Z
publishDate 2017-10-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-7f07b0eedc8a44a79bdf9bc99af027862022-12-22T04:24:15ZengMDPI AGEnergies1996-10732017-10-011011174610.3390/en10111746en10111746Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off TemperatureOsman Wageiallah Mohammed0Guo Yanling1College of Mechanical and Electrical Engineering, Northeast Forestry University, Harbin 150000, ChinaCollege of Mechanical and Electrical Engineering, Northeast Forestry University, Harbin 150000, ChinaSolar-driven ammonia-water absorption refrigeration system (AARS) has been considered as an alternative for the conventional refrigeration and air-conditioning systems. However, its high initial cost seems to be the main problem that postpones its wide spread use. In the present study, a single-stage NH3/H2O ARS is analyzed in depth on the basis of energetic and exergetic coefficients of performance (COP and ECOP, respectively) to decrease its cut in/off temperature. This study was carried out to lower the required heat source temperature, so that a less-expensive solar collector could be used. Effects of all parameters that could influence the system’s performance and cut in/off temperature were investigated in detail. Presence of water in the refrigerant and evaporator temperature glide was considered. Results revealed that appropriate selection of system’s working condition can effectively reduce the driving temperature. Besides, the cut in/off temperature can be significantly decreased by inserting an effective solution heat exchanger (SHX). Required driving temperature can be lowered by up to 10 °C using SHX with 0.80 effectiveness. The results also showed that effects of water content in the refrigerant could not be neglected in studying NH3/H2O ARS because it affects both COP and ECOP. Additionally, a large temperature glide in the evaporator can substantially decrease the ECOP.https://www.mdpi.com/1996-1073/10/11/1746solar assisted coolingheat pumpssolar thermal systemsabsorption refrigeration
spellingShingle Osman Wageiallah Mohammed
Guo Yanling
Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature
Energies
solar assisted cooling
heat pumps
solar thermal systems
absorption refrigeration
title Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature
title_full Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature
title_fullStr Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature
title_full_unstemmed Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature
title_short Comprehensive Parametric Study of a Solar Absorption Refrigeration System to Lower Its Cut In/Off Temperature
title_sort comprehensive parametric study of a solar absorption refrigeration system to lower its cut in off temperature
topic solar assisted cooling
heat pumps
solar thermal systems
absorption refrigeration
url https://www.mdpi.com/1996-1073/10/11/1746
work_keys_str_mv AT osmanwageiallahmohammed comprehensiveparametricstudyofasolarabsorptionrefrigerationsystemtoloweritscutinofftemperature
AT guoyanling comprehensiveparametricstudyofasolarabsorptionrefrigerationsystemtoloweritscutinofftemperature