Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice

We describe here a simple, cost-effective apparatus for continuous tethered electroencephalographic (EEG) monitoring of spontaneous recurrent seizures in mice. We used a small, low torque slip ring as an EEG commutator, mounted the slip ring onto a standard mouse cage and connected rotary wires of t...

Full description

Bibliographic Details
Main Authors: Na-Ryum Bin, Hongmei Song, Chiping Wu, Marcus Lau, Shuzo Sugita, James H. Eubanks, Liang Zhang
Format: Article
Language:English
Published: Frontiers Media S.A. 2017-09-01
Series:Frontiers in Behavioral Neuroscience
Subjects:
Online Access:http://journal.frontiersin.org/article/10.3389/fnbeh.2017.00172/full
_version_ 1818230892724748288
author Na-Ryum Bin
Na-Ryum Bin
Hongmei Song
Hongmei Song
Chiping Wu
Marcus Lau
Shuzo Sugita
Shuzo Sugita
James H. Eubanks
James H. Eubanks
James H. Eubanks
James H. Eubanks
Liang Zhang
Liang Zhang
Liang Zhang
author_facet Na-Ryum Bin
Na-Ryum Bin
Hongmei Song
Hongmei Song
Chiping Wu
Marcus Lau
Shuzo Sugita
Shuzo Sugita
James H. Eubanks
James H. Eubanks
James H. Eubanks
James H. Eubanks
Liang Zhang
Liang Zhang
Liang Zhang
author_sort Na-Ryum Bin
collection DOAJ
description We describe here a simple, cost-effective apparatus for continuous tethered electroencephalographic (EEG) monitoring of spontaneous recurrent seizures in mice. We used a small, low torque slip ring as an EEG commutator, mounted the slip ring onto a standard mouse cage and connected rotary wires of the slip ring directly to animal's implanted headset. Modifications were made in the cage to allow for a convenient installation of the slip ring and accommodation of animal ambient activity. We tested the apparatus for hippocampal EEG recordings in adult C57 black mice. Spontaneous recurrent seizures were induced using extended hippocampal kindling (≥95 daily stimulation). Control animals underwent similar hippocampal electrode implantations but no stimulations were given. Combined EEG and webcam monitoring were performed for 24 h daily for 5–9 consecutive days. During the monitoring periods, the animals moved and accessed water and food freely and showed no apparent restriction in ambient cage activities. Ictal-like hippocampal EEG discharges and concurrent convulsive behaviors that are characteristics of spontaneous recurrent seizures were reliably recorded in a majority of the monitoring experiments in extendedly kindled but not in control animals. However, 1–2 rotary wires were disconnected from the implanted headset in some animals after continuous recordings for ≥5 days. The key features and main limitations of our recording apparatus are discussed.
first_indexed 2024-12-12T10:41:43Z
format Article
id doaj.art-7faa05100ae6463896df035abf3ec267
institution Directory Open Access Journal
issn 1662-5153
language English
last_indexed 2024-12-12T10:41:43Z
publishDate 2017-09-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Behavioral Neuroscience
spelling doaj.art-7faa05100ae6463896df035abf3ec2672022-12-22T00:27:02ZengFrontiers Media S.A.Frontiers in Behavioral Neuroscience1662-51532017-09-011110.3389/fnbeh.2017.00172271328Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in MiceNa-Ryum Bin0Na-Ryum Bin1Hongmei Song2Hongmei Song3Chiping Wu4Marcus Lau5Shuzo Sugita6Shuzo Sugita7James H. Eubanks8James H. Eubanks9James H. Eubanks10James H. Eubanks11Liang Zhang12Liang Zhang13Liang Zhang14Krembil Research Institute, University Health NetworkToronto, ON, CanadaDepartment of Physiology, University of TorontoToronto, ON, CanadaKrembil Research Institute, University Health NetworkToronto, ON, CanadaDepartment of Neurosurgery, The First Hospital of Jilin UniversityJilin, ChinaKrembil Research Institute, University Health NetworkToronto, ON, CanadaKrembil Research Institute, University Health NetworkToronto, ON, CanadaKrembil Research Institute, University Health NetworkToronto, ON, CanadaDepartment of Physiology, University of TorontoToronto, ON, CanadaKrembil Research Institute, University Health NetworkToronto, ON, CanadaDepartment of Physiology, University of TorontoToronto, ON, CanadaDivision of Neurosurgery, Department of Surgery, University of TorontoToronto, ON, CanadaThe Epilepsy Research Program of Ontario Brain InstituteToronto, ON, CanadaKrembil Research Institute, University Health NetworkToronto, ON, CanadaThe Epilepsy Research Program of Ontario Brain InstituteToronto, ON, CanadaDivision of Neurology, Department of Medicine, University of TorontoToronto, ON, CanadaWe describe here a simple, cost-effective apparatus for continuous tethered electroencephalographic (EEG) monitoring of spontaneous recurrent seizures in mice. We used a small, low torque slip ring as an EEG commutator, mounted the slip ring onto a standard mouse cage and connected rotary wires of the slip ring directly to animal's implanted headset. Modifications were made in the cage to allow for a convenient installation of the slip ring and accommodation of animal ambient activity. We tested the apparatus for hippocampal EEG recordings in adult C57 black mice. Spontaneous recurrent seizures were induced using extended hippocampal kindling (≥95 daily stimulation). Control animals underwent similar hippocampal electrode implantations but no stimulations were given. Combined EEG and webcam monitoring were performed for 24 h daily for 5–9 consecutive days. During the monitoring periods, the animals moved and accessed water and food freely and showed no apparent restriction in ambient cage activities. Ictal-like hippocampal EEG discharges and concurrent convulsive behaviors that are characteristics of spontaneous recurrent seizures were reliably recorded in a majority of the monitoring experiments in extendedly kindled but not in control animals. However, 1–2 rotary wires were disconnected from the implanted headset in some animals after continuous recordings for ≥5 days. The key features and main limitations of our recording apparatus are discussed.http://journal.frontiersin.org/article/10.3389/fnbeh.2017.00172/fullconvulsiondischargesEEGepilepsyhippocampuskindling
spellingShingle Na-Ryum Bin
Na-Ryum Bin
Hongmei Song
Hongmei Song
Chiping Wu
Marcus Lau
Shuzo Sugita
Shuzo Sugita
James H. Eubanks
James H. Eubanks
James H. Eubanks
James H. Eubanks
Liang Zhang
Liang Zhang
Liang Zhang
Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice
Frontiers in Behavioral Neuroscience
convulsion
discharges
EEG
epilepsy
hippocampus
kindling
title Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice
title_full Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice
title_fullStr Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice
title_full_unstemmed Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice
title_short Continuous Monitoring via Tethered Electroencephalography of Spontaneous Recurrent Seizures in Mice
title_sort continuous monitoring via tethered electroencephalography of spontaneous recurrent seizures in mice
topic convulsion
discharges
EEG
epilepsy
hippocampus
kindling
url http://journal.frontiersin.org/article/10.3389/fnbeh.2017.00172/full
work_keys_str_mv AT naryumbin continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT naryumbin continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT hongmeisong continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT hongmeisong continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT chipingwu continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT marcuslau continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT shuzosugita continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT shuzosugita continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT jamesheubanks continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT jamesheubanks continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT jamesheubanks continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT jamesheubanks continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT liangzhang continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT liangzhang continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice
AT liangzhang continuousmonitoringviatetheredelectroencephalographyofspontaneousrecurrentseizuresinmice