Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab Simulink

This paper describes the work done in order to make Matlab Simulink based steam generator simulator in the simulation of a steam generator. The steam generator under this research is operated with the steam quality of 72%, O2 content is 1.2%, designed steam volume flow is 3600 barrel per day at a ma...

Full description

Bibliographic Details
Main Authors: Ikhtiander, Santoso Soekirno
Format: Article
Language:English
Published: EDP Sciences 2018-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20184301012
_version_ 1818665014669606912
author Ikhtiander
Santoso Soekirno
author_facet Ikhtiander
Santoso Soekirno
author_sort Ikhtiander
collection DOAJ
description This paper describes the work done in order to make Matlab Simulink based steam generator simulator in the simulation of a steam generator. The steam generator under this research is operated with the steam quality of 72%, O2 content is 1.2%, designed steam volume flow is 3600 barrel per day at a maximum and designed fuel gas volume flow is 1300 Thousand Standard Cubic Feet (MSCF) per day at a maximum. The simulator program of the steam generator is separated into individual components consisting of Burner, Radiant, Convection, Exhaust Stack, Feedwater Pump Discharge and Steam Discharge. Within the components, thermodynamics and heat transfer principles such as conduction, convection, radiation and also conservation of mass, momentum, and energy were applied to compute the pressure values, temperature values, and flow rate values of simulated field device based on the command and setpoint from PLC. The validation process has been done with the steam generator is operating in a steady state to the 10 important process parameters of the steam generator. The error percentage calculated from a difference between the simulation result value and the actual value from field data reference divide by actual value from field data reference. The error percentage results are as following : Fuel Gas Orifice Differential Pressure : 2.39%, Fuel Gas Pressure : 1.37%, Fuel Gas Temperature : 5.95%, Fuel Gas Flow Rate : 1.25%, Feedwater Orifice Differential Pressure : 1.94%, Feedwater Pressure : 1.54%, Feedwater Flow Rate : 0.92%, Steam Orifice Differential Pressure 3.26%, Steam Discharge Pressure 1.93% and Steam Quality : 0.05%.
first_indexed 2024-12-17T05:41:54Z
format Article
id doaj.art-80d01ab2ff7f4701ab2313017767c689
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-12-17T05:41:54Z
publishDate 2018-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-80d01ab2ff7f4701ab2313017767c6892022-12-21T22:01:25ZengEDP SciencesE3S Web of Conferences2267-12422018-01-01430101210.1051/e3sconf/20184301012e3sconf_astechnova2017_01012Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab SimulinkIkhtianderSantoso SoekirnoThis paper describes the work done in order to make Matlab Simulink based steam generator simulator in the simulation of a steam generator. The steam generator under this research is operated with the steam quality of 72%, O2 content is 1.2%, designed steam volume flow is 3600 barrel per day at a maximum and designed fuel gas volume flow is 1300 Thousand Standard Cubic Feet (MSCF) per day at a maximum. The simulator program of the steam generator is separated into individual components consisting of Burner, Radiant, Convection, Exhaust Stack, Feedwater Pump Discharge and Steam Discharge. Within the components, thermodynamics and heat transfer principles such as conduction, convection, radiation and also conservation of mass, momentum, and energy were applied to compute the pressure values, temperature values, and flow rate values of simulated field device based on the command and setpoint from PLC. The validation process has been done with the steam generator is operating in a steady state to the 10 important process parameters of the steam generator. The error percentage calculated from a difference between the simulation result value and the actual value from field data reference divide by actual value from field data reference. The error percentage results are as following : Fuel Gas Orifice Differential Pressure : 2.39%, Fuel Gas Pressure : 1.37%, Fuel Gas Temperature : 5.95%, Fuel Gas Flow Rate : 1.25%, Feedwater Orifice Differential Pressure : 1.94%, Feedwater Pressure : 1.54%, Feedwater Flow Rate : 0.92%, Steam Orifice Differential Pressure 3.26%, Steam Discharge Pressure 1.93% and Steam Quality : 0.05%.https://doi.org/10.1051/e3sconf/20184301012
spellingShingle Ikhtiander
Santoso Soekirno
Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab Simulink
E3S Web of Conferences
title Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab Simulink
title_full Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab Simulink
title_fullStr Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab Simulink
title_full_unstemmed Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab Simulink
title_short Design of PLC Integrated Process Simulation Software for Steam Generator Using Matlab Simulink
title_sort design of plc integrated process simulation software for steam generator using matlab simulink
url https://doi.org/10.1051/e3sconf/20184301012
work_keys_str_mv AT ikhtiander designofplcintegratedprocesssimulationsoftwareforsteamgeneratorusingmatlabsimulink
AT santososoekirno designofplcintegratedprocesssimulationsoftwareforsteamgeneratorusingmatlabsimulink