Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis

Key Clinical Message Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Abstract Left ventricle assist devices (LVAD...

Full description

Bibliographic Details
Main Authors: Mohamed Elbayomi, Michael Weyand, Michael Uder, Matthias S. May, Katrin Steger, Jan‐Peter Roth, Rene Tandler
Format: Article
Language:English
Published: Wiley 2023-05-01
Series:Clinical Case Reports
Subjects:
Online Access:https://doi.org/10.1002/ccr3.7349
_version_ 1797820447672238080
author Mohamed Elbayomi
Michael Weyand
Michael Uder
Matthias S. May
Katrin Steger
Jan‐Peter Roth
Rene Tandler
author_facet Mohamed Elbayomi
Michael Weyand
Michael Uder
Matthias S. May
Katrin Steger
Jan‐Peter Roth
Rene Tandler
author_sort Mohamed Elbayomi
collection DOAJ
description Key Clinical Message Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Abstract Left ventricle assist devices (LVADs) provide life‐sustaining treatment for patients with terminal heart failure, but their intricacy allows for complications. One complication is LVAD outflow graft obstruction due to the graft's intraluminal thrombus or extraluminal compression. It may be treated endovascularly with stenting. We report an endovascular stenting of an outflow tract in HVAD™ (HeartWare Inc.) due to a pseudoaneurysm causing compression and kinking stenosis.
first_indexed 2024-03-13T09:38:30Z
format Article
id doaj.art-81284afdf49444a6ad40e814d8cfe2ba
institution Directory Open Access Journal
issn 2050-0904
language English
last_indexed 2024-03-13T09:38:30Z
publishDate 2023-05-01
publisher Wiley
record_format Article
series Clinical Case Reports
spelling doaj.art-81284afdf49444a6ad40e814d8cfe2ba2023-05-25T05:58:40ZengWileyClinical Case Reports2050-09042023-05-01115n/an/a10.1002/ccr3.7349Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesisMohamed Elbayomi0Michael Weyand1Michael Uder2Matthias S. May3Katrin Steger4Jan‐Peter Roth5Rene Tandler6Department of Cardiac Surgery Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen GermanyDepartment of Cardiac Surgery Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen GermanyDepartment of Radiology Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen GermanyDepartment of Radiology Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen GermanyDepartment of Cardiac Surgery Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen GermanyDepartment of Radiology Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen GermanyDepartment of Cardiac Surgery Friedrich‐Alexander‐University Erlangen‐Nuremberg Erlangen GermanyKey Clinical Message Complex presentations of MCS patients may necessitate a multidisciplinary approach involving HF cardiologists, CT surgeons, advanced cardiac imagers, and interventional cardiologists in order to define the optimal management strategy. Abstract Left ventricle assist devices (LVADs) provide life‐sustaining treatment for patients with terminal heart failure, but their intricacy allows for complications. One complication is LVAD outflow graft obstruction due to the graft's intraluminal thrombus or extraluminal compression. It may be treated endovascularly with stenting. We report an endovascular stenting of an outflow tract in HVAD™ (HeartWare Inc.) due to a pseudoaneurysm causing compression and kinking stenosis.https://doi.org/10.1002/ccr3.7349case reportendovascular stentingMedtronic/HeartWare HVAD
spellingShingle Mohamed Elbayomi
Michael Weyand
Michael Uder
Matthias S. May
Katrin Steger
Jan‐Peter Roth
Rene Tandler
Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
Clinical Case Reports
case report
endovascular stenting
Medtronic/HeartWare HVAD
title Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
title_full Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
title_fullStr Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
title_full_unstemmed Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
title_short Endovascular stenting of an HVAD™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
title_sort endovascular stenting of an hvad™ outflow graft pseudoaneurysm that exerts compression and kinking stenosis on the soft portion of the prosthesis
topic case report
endovascular stenting
Medtronic/HeartWare HVAD
url https://doi.org/10.1002/ccr3.7349
work_keys_str_mv AT mohamedelbayomi endovascularstentingofanhvadoutflowgraftpseudoaneurysmthatexertscompressionandkinkingstenosisonthesoftportionoftheprosthesis
AT michaelweyand endovascularstentingofanhvadoutflowgraftpseudoaneurysmthatexertscompressionandkinkingstenosisonthesoftportionoftheprosthesis
AT michaeluder endovascularstentingofanhvadoutflowgraftpseudoaneurysmthatexertscompressionandkinkingstenosisonthesoftportionoftheprosthesis
AT matthiassmay endovascularstentingofanhvadoutflowgraftpseudoaneurysmthatexertscompressionandkinkingstenosisonthesoftportionoftheprosthesis
AT katrinsteger endovascularstentingofanhvadoutflowgraftpseudoaneurysmthatexertscompressionandkinkingstenosisonthesoftportionoftheprosthesis
AT janpeterroth endovascularstentingofanhvadoutflowgraftpseudoaneurysmthatexertscompressionandkinkingstenosisonthesoftportionoftheprosthesis
AT renetandler endovascularstentingofanhvadoutflowgraftpseudoaneurysmthatexertscompressionandkinkingstenosisonthesoftportionoftheprosthesis