Use of a simple passive monitoring system to assess detention basin stormwater
Abstract The ability to monitor stormwater quality while in detention basins would be useful for stormwater managers. A simple passive method of monitoring vertical elevations of pooled stormwater in detention basins was developed. The simple method used plastic buckets with holes drilled into them...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Springer
2023-05-01
|
Series: | Discover Water |
Subjects: | |
Online Access: | https://doi.org/10.1007/s43832-023-00032-2 |
_version_ | 1797827383907057664 |
---|---|
author | Jesse Riley Christina Hargiss Jack Norland |
author_facet | Jesse Riley Christina Hargiss Jack Norland |
author_sort | Jesse Riley |
collection | DOAJ |
description | Abstract The ability to monitor stormwater quality while in detention basins would be useful for stormwater managers. A simple passive method of monitoring vertical elevations of pooled stormwater in detention basins was developed. The simple method used plastic buckets with holes drilled into them to collect water as stormwater filled the basin from first flush to peak. The method was installed at three different detention basins and stormwater was collected using the simple passive system at different vertical pool elevations for three storm events. Total suspended solids were found to decline from first flush in keeping with other studies on stormwater. In addition, total phosphorous and E. coli were found to differ among storm events and pool elevations. The simple passive vertical water quality assessment system was found to produce reliable results similar to what others have found. The advantages of this assessment method were that it reduced exposure of personnel to hazardous conditions, was low cost, and was a simple, uncomplicated way to sample stormwater. |
first_indexed | 2024-04-09T12:47:24Z |
format | Article |
id | doaj.art-81540a13ac22450a9d95c41a7ecf9448 |
institution | Directory Open Access Journal |
issn | 2730-647X |
language | English |
last_indexed | 2024-04-09T12:47:24Z |
publishDate | 2023-05-01 |
publisher | Springer |
record_format | Article |
series | Discover Water |
spelling | doaj.art-81540a13ac22450a9d95c41a7ecf94482023-05-14T11:27:06ZengSpringerDiscover Water2730-647X2023-05-01311710.1007/s43832-023-00032-2Use of a simple passive monitoring system to assess detention basin stormwaterJesse Riley0Christina Hargiss1Jack Norland2School of Natural Resource Sciences, Natural Resources Management, North Dakota State UniversitySchool of Natural Resource Sciences, Natural Resources Management, North Dakota State UniversitySchool of Natural Resource Sciences, Natural Resources Management, North Dakota State UniversityAbstract The ability to monitor stormwater quality while in detention basins would be useful for stormwater managers. A simple passive method of monitoring vertical elevations of pooled stormwater in detention basins was developed. The simple method used plastic buckets with holes drilled into them to collect water as stormwater filled the basin from first flush to peak. The method was installed at three different detention basins and stormwater was collected using the simple passive system at different vertical pool elevations for three storm events. Total suspended solids were found to decline from first flush in keeping with other studies on stormwater. In addition, total phosphorous and E. coli were found to differ among storm events and pool elevations. The simple passive vertical water quality assessment system was found to produce reliable results similar to what others have found. The advantages of this assessment method were that it reduced exposure of personnel to hazardous conditions, was low cost, and was a simple, uncomplicated way to sample stormwater.https://doi.org/10.1007/s43832-023-00032-2StormwaterDetention basinPassive monitoringWater qualityFirst flush |
spellingShingle | Jesse Riley Christina Hargiss Jack Norland Use of a simple passive monitoring system to assess detention basin stormwater Discover Water Stormwater Detention basin Passive monitoring Water quality First flush |
title | Use of a simple passive monitoring system to assess detention basin stormwater |
title_full | Use of a simple passive monitoring system to assess detention basin stormwater |
title_fullStr | Use of a simple passive monitoring system to assess detention basin stormwater |
title_full_unstemmed | Use of a simple passive monitoring system to assess detention basin stormwater |
title_short | Use of a simple passive monitoring system to assess detention basin stormwater |
title_sort | use of a simple passive monitoring system to assess detention basin stormwater |
topic | Stormwater Detention basin Passive monitoring Water quality First flush |
url | https://doi.org/10.1007/s43832-023-00032-2 |
work_keys_str_mv | AT jesseriley useofasimplepassivemonitoringsystemtoassessdetentionbasinstormwater AT christinahargiss useofasimplepassivemonitoringsystemtoassessdetentionbasinstormwater AT jacknorland useofasimplepassivemonitoringsystemtoassessdetentionbasinstormwater |