A fast calculation method of transient hot spot temperature for the design of dry‐type on‐board transformers
Abstract The design of the dry‐type on‐board traction transformer (OBTT), a new lightweight method in the traction system of electric multiple units, needs to consider the transient hot spot temperature (HST) under different railroad line operating conditions. In order to quickly calculate the trans...
Main Authors: | Lei Guo, Fenglin Cai, Qiuyue Zhu, Shuai Yuan, Dongyang Wang, Lijun Zhou |
---|---|
Format: | Article |
Language: | English |
Published: |
Wiley
2023-01-01
|
Series: | IET Electric Power Applications |
Subjects: | |
Online Access: | https://doi.org/10.1049/elp2.12246 |
Similar Items
-
Prediction of binding hot spot residues by using structural and evolutionary parameters
by: Roberto Hiroshi Higa, et al.
Published: (2009-01-01) -
SpotFuzz: Fuzzing Based on Program Hot-Spots
by: Haibo Pang, et al.
Published: (2021-12-01) -
Fuzzy-Based Spatiotemporal Hot Spot Intensity and Propagation—An Application in Crime Analysis
by: Barbara Cardone, et al.
Published: (2022-01-01) -
Calculation of Hot Spot Temperature of Transformer Bushing Considering Current Fluctuation
by: Zhifei Yang, et al.
Published: (2019-01-01) -
Oil Immersed Distribution Transformer HST Reduction using Vegetable Oils and ONAN Cooling
by: Mohammad Ali Taghikhani
Published: (2024-01-01)