Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems
In this paper, by analyzing the effects of two different kinds of implant-abutment connection interfaces under the same working condition on the mechanical and fatigue performances of the implant system as well as on the surrounding bones, we intend to study such effects on the reliability of the im...
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
EDP Sciences
2016-01-01
|
Series: | MATEC Web of Conferences |
Online Access: | http://dx.doi.org/10.1051/matecconf/20167708006 |
_version_ | 1818622339633381376 |
---|---|
author | Zhang Xiao Liu Lei Wang Yaling Chen Xianshuai |
author_facet | Zhang Xiao Liu Lei Wang Yaling Chen Xianshuai |
author_sort | Zhang Xiao |
collection | DOAJ |
description | In this paper, by analyzing the effects of two different kinds of implant-abutment connection interfaces under the same working condition on the mechanical and fatigue performances of the implant system as well as on the surrounding bones, we intend to study such effects on the reliability of the implants and provide a theoretical basis for the design and clinical application of dental implant systems. For the purpose, we adopt a 3-D modeling method to establish the model, and use FEA (finite element analysis) to carry out static mechanic and fatigue analysis on the implant system and its surrounding bones; then we make the two implant systems, and carry out fatigue tests on a dynamic fatigue testing machine to verify the FEA results. After comparing the results from the two different systems, we find that the stress distribution and fatigue safety factor of the system which has deeper axial matching of the taper connection are better than those of the other system, that is to say, between the two major elements of a implant system, the axial length of the connecting taper and the size of the hexagon, the former has greater effects than the latter. When the axial matching is deeper, the stress distribution of the implant system will be better, the fatigue safety factor will be higher, and the implant system will be more reliable. |
first_indexed | 2024-12-16T18:23:36Z |
format | Article |
id | doaj.art-81b11a0805054a5ab74ee8a3eb16a23d |
institution | Directory Open Access Journal |
issn | 2261-236X |
language | English |
last_indexed | 2024-12-16T18:23:36Z |
publishDate | 2016-01-01 |
publisher | EDP Sciences |
record_format | Article |
series | MATEC Web of Conferences |
spelling | doaj.art-81b11a0805054a5ab74ee8a3eb16a23d2022-12-21T22:21:29ZengEDP SciencesMATEC Web of Conferences2261-236X2016-01-01770800610.1051/matecconf/20167708006matecconf_icmmr2016_08006Effects of Dental Implant-abutment Interfaces on the Reliability of Implant SystemsZhang Xiao0Liu LeiWang Yaling1Chen XianshuaiShenzhen Institutes of Advanced TechnologyShenzhen Institutes of Advanced TechnologyIn this paper, by analyzing the effects of two different kinds of implant-abutment connection interfaces under the same working condition on the mechanical and fatigue performances of the implant system as well as on the surrounding bones, we intend to study such effects on the reliability of the implants and provide a theoretical basis for the design and clinical application of dental implant systems. For the purpose, we adopt a 3-D modeling method to establish the model, and use FEA (finite element analysis) to carry out static mechanic and fatigue analysis on the implant system and its surrounding bones; then we make the two implant systems, and carry out fatigue tests on a dynamic fatigue testing machine to verify the FEA results. After comparing the results from the two different systems, we find that the stress distribution and fatigue safety factor of the system which has deeper axial matching of the taper connection are better than those of the other system, that is to say, between the two major elements of a implant system, the axial length of the connecting taper and the size of the hexagon, the former has greater effects than the latter. When the axial matching is deeper, the stress distribution of the implant system will be better, the fatigue safety factor will be higher, and the implant system will be more reliable.http://dx.doi.org/10.1051/matecconf/20167708006 |
spellingShingle | Zhang Xiao Liu Lei Wang Yaling Chen Xianshuai Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems MATEC Web of Conferences |
title | Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems |
title_full | Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems |
title_fullStr | Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems |
title_full_unstemmed | Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems |
title_short | Effects of Dental Implant-abutment Interfaces on the Reliability of Implant Systems |
title_sort | effects of dental implant abutment interfaces on the reliability of implant systems |
url | http://dx.doi.org/10.1051/matecconf/20167708006 |
work_keys_str_mv | AT zhangxiao effectsofdentalimplantabutmentinterfacesonthereliabilityofimplantsystems AT liulei effectsofdentalimplantabutmentinterfacesonthereliabilityofimplantsystems AT wangyaling effectsofdentalimplantabutmentinterfacesonthereliabilityofimplantsystems AT chenxianshuai effectsofdentalimplantabutmentinterfacesonthereliabilityofimplantsystems |