Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2

The goal of this study was to evaluate the performance of a commercial reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay (Detect COVID-19 Test) in the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A total of 202 human respiratory and viral cult...

Full description

Bibliographic Details
Main Authors: Janet Hei Yin Law, Wai Sing Chan, Tsun Leung Chan, Edmond Shiu Kwan Ma, Bone Siu Fai Tang
Format: Article
Language:English
Published: MDPI AG 2023-08-01
Series:Biomedicines
Subjects:
Online Access:https://www.mdpi.com/2227-9059/11/9/2344
_version_ 1827727082673668096
author Janet Hei Yin Law
Wai Sing Chan
Tsun Leung Chan
Edmond Shiu Kwan Ma
Bone Siu Fai Tang
author_facet Janet Hei Yin Law
Wai Sing Chan
Tsun Leung Chan
Edmond Shiu Kwan Ma
Bone Siu Fai Tang
author_sort Janet Hei Yin Law
collection DOAJ
description The goal of this study was to evaluate the performance of a commercial reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay (Detect COVID-19 Test) in the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A total of 202 human respiratory and viral culture specimens were tested retrospectively. The performance of the Detect COVID-19 Test was comparable to that of commercial real-time polymerase chain reaction assays (sensitivity: 93.42%; specificity: 100%), and better than that of the rapid antigen test (sensitivity: 48.00%; specificity: 100%) for specimens with threshold cycle (Ct) values of less than 30. The Beta, Delta, and Omicron variants of concern were successfully detected. With their simplicity of use and good assay sensitivity, point-of-care RT-LAMP assays may be a viable option for SARS-CoV-2 testing at home, or in regions without sophisticated laboratory facilities.
first_indexed 2024-03-10T23:01:31Z
format Article
id doaj.art-8248eebd18cd479c9b1994f1ed267bc0
institution Directory Open Access Journal
issn 2227-9059
language English
last_indexed 2024-03-10T23:01:31Z
publishDate 2023-08-01
publisher MDPI AG
record_format Article
series Biomedicines
spelling doaj.art-8248eebd18cd479c9b1994f1ed267bc02023-11-19T09:39:59ZengMDPI AGBiomedicines2227-90592023-08-01119234410.3390/biomedicines11092344Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2Janet Hei Yin Law0Wai Sing Chan1Tsun Leung Chan2Edmond Shiu Kwan Ma3Bone Siu Fai Tang4Department of Pathology, Hong Kong Sanatorium and Hospital, Hong Kong SAR, ChinaDepartment of Pathology, Hong Kong Sanatorium and Hospital, Hong Kong SAR, ChinaDepartment of Pathology, Hong Kong Sanatorium and Hospital, Hong Kong SAR, ChinaDepartment of Pathology, Hong Kong Sanatorium and Hospital, Hong Kong SAR, ChinaDepartment of Pathology, Hong Kong Sanatorium and Hospital, Hong Kong SAR, ChinaThe goal of this study was to evaluate the performance of a commercial reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay (Detect COVID-19 Test) in the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). A total of 202 human respiratory and viral culture specimens were tested retrospectively. The performance of the Detect COVID-19 Test was comparable to that of commercial real-time polymerase chain reaction assays (sensitivity: 93.42%; specificity: 100%), and better than that of the rapid antigen test (sensitivity: 48.00%; specificity: 100%) for specimens with threshold cycle (Ct) values of less than 30. The Beta, Delta, and Omicron variants of concern were successfully detected. With their simplicity of use and good assay sensitivity, point-of-care RT-LAMP assays may be a viable option for SARS-CoV-2 testing at home, or in regions without sophisticated laboratory facilities.https://www.mdpi.com/2227-9059/11/9/2344COVID-19Detect COVID-19 TestRT-LAMPPOCTSARS-CoV-2variants of concern
spellingShingle Janet Hei Yin Law
Wai Sing Chan
Tsun Leung Chan
Edmond Shiu Kwan Ma
Bone Siu Fai Tang
Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2
Biomedicines
COVID-19
Detect COVID-19 Test
RT-LAMP
POCT
SARS-CoV-2
variants of concern
title Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2
title_full Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2
title_fullStr Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2
title_full_unstemmed Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2
title_short Evaluation of a Commercial Point-of-Care RT-LAMP Assay for Rapid Detection of SARS-CoV-2
title_sort evaluation of a commercial point of care rt lamp assay for rapid detection of sars cov 2
topic COVID-19
Detect COVID-19 Test
RT-LAMP
POCT
SARS-CoV-2
variants of concern
url https://www.mdpi.com/2227-9059/11/9/2344
work_keys_str_mv AT janetheiyinlaw evaluationofacommercialpointofcarertlampassayforrapiddetectionofsarscov2
AT waisingchan evaluationofacommercialpointofcarertlampassayforrapiddetectionofsarscov2
AT tsunleungchan evaluationofacommercialpointofcarertlampassayforrapiddetectionofsarscov2
AT edmondshiukwanma evaluationofacommercialpointofcarertlampassayforrapiddetectionofsarscov2
AT bonesiufaitang evaluationofacommercialpointofcarertlampassayforrapiddetectionofsarscov2