Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer

For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have...

Full description

Bibliographic Details
Main Authors: Mohamed Yassine Herrassi, Farida Bentayeb, Maria Rosa Malisan
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2013-01-01
Series:Journal of Medical Physics
Subjects:
Online Access:http://www.jmp.org.in/article.asp?issn=0971-6203;year=2013;volume=38;issue=2;spage=98;epage=105;aulast=Herrassi
_version_ 1818361363032965120
author Mohamed Yassine Herrassi
Farida Bentayeb
Maria Rosa Malisan
author_facet Mohamed Yassine Herrassi
Farida Bentayeb
Maria Rosa Malisan
author_sort Mohamed Yassine Herrassi
collection DOAJ
description For the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OAR′s, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OAR′s DVH′s as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment.
first_indexed 2024-12-13T21:15:29Z
format Article
id doaj.art-82a0f12e32ab4d6c9738aa22ccec9da4
institution Directory Open Access Journal
issn 0971-6203
1998-3913
language English
last_indexed 2024-12-13T21:15:29Z
publishDate 2013-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Journal of Medical Physics
spelling doaj.art-82a0f12e32ab4d6c9738aa22ccec9da42022-12-21T23:31:14ZengWolters Kluwer Medknow PublicationsJournal of Medical Physics0971-62031998-39132013-01-013829810510.4103/0971-6203.111331Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancerMohamed Yassine HerrassiFarida BentayebMaria Rosa MalisanFor the head-and-neck cancer bilateral irradiation, intensity-modulated radiation therapy (IMRT) is the most reported technique as it enables both target dose coverage and organ-at-risk (OAR) sparing. However, during the last 20 years, three-dimensional conformal radiotherapy (3DCRT) techniques have been introduced, which are tailored to improve the classic shrinking field technique, as regards both planning target volume (PTV) dose conformality and sparing of OAR′s, such as parotid glands and spinal cord. In this study, we tested experimentally in a sample of 13 patients, four of these advanced 3DCRT techniques, all using photon beams only and a unique isocentre, namely Bellinzona, Forward-Planned Multisegments (FPMS), ConPas, and field-in-field (FIF) techniques. Statistical analysis of the main dosimetric parameters of PTV and OAR′s DVH′s as well as of homogeneity and conformity indexes was carried out in order to compare the performance of each technique. The results show that the PTV dose coverage is adequate for all the techniques, with the FPMS techniques providing the highest value for D95%; on the other hand, the best sparing of parotid glands is achieved using the FIF and ConPas techniques, with a mean dose of 26 Gy to parotid glands for a PTV prescription dose of 54 Gy. After taking into account both PTV coverage and parotid sparing, the best global performance was achieved by the FIF technique with results comparable to that of IMRT plans. This technique can be proposed as a valid alternative when IMRT equipment is not available or patient is not suitable for IMRT treatment.http://www.jmp.org.in/article.asp?issn=0971-6203;year=2013;volume=38;issue=2;spage=98;epage=105;aulast=HerrassiHead and neck3DCRT techniquesdosimetric comparison
spellingShingle Mohamed Yassine Herrassi
Farida Bentayeb
Maria Rosa Malisan
Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer
Journal of Medical Physics
Head and neck
3DCRT techniques
dosimetric comparison
title Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer
title_full Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer
title_fullStr Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer
title_full_unstemmed Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer
title_short Comparative study of four advanced 3d-conformal radiation therapy treatment planning techniques for head and neck cancer
title_sort comparative study of four advanced 3d conformal radiation therapy treatment planning techniques for head and neck cancer
topic Head and neck
3DCRT techniques
dosimetric comparison
url http://www.jmp.org.in/article.asp?issn=0971-6203;year=2013;volume=38;issue=2;spage=98;epage=105;aulast=Herrassi
work_keys_str_mv AT mohamedyassineherrassi comparativestudyoffouradvanced3dconformalradiationtherapytreatmentplanningtechniquesforheadandneckcancer
AT faridabentayeb comparativestudyoffouradvanced3dconformalradiationtherapytreatmentplanningtechniquesforheadandneckcancer
AT mariarosamalisan comparativestudyoffouradvanced3dconformalradiationtherapytreatmentplanningtechniquesforheadandneckcancer