Automatic tracking method of reference waveform of mine ultrasonic gas flowmeter

The accuracy of mine ultrasonic gas flowmeter needs to be improved. The cross-correlation detection signal has 'signal hopping' phenomenon and affects the measurement precision of ultrasonic transit time. In order to solve the above problems, this paper proposes an automatic tracking metho...

Full description

Bibliographic Details
Main Author: BAI Sizhong
Format: Article
Language:zho
Published: Editorial Department of Industry and Mine Automation 2022-04-01
Series:Gong-kuang zidonghua
Subjects:
Online Access:http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2021080082
_version_ 1827988575529992192
author BAI Sizhong
author_facet BAI Sizhong
author_sort BAI Sizhong
collection DOAJ
description The accuracy of mine ultrasonic gas flowmeter needs to be improved. The cross-correlation detection signal has 'signal hopping' phenomenon and affects the measurement precision of ultrasonic transit time. In order to solve the above problems, this paper proposes an automatic tracking method of reference waveform of mine ultrasonic gas flowmeter. While calculating the ultrasonic transit time, the cross-correlation operation is carried out between the ultrasonic reference waveform and the real-time received signal waveform. The reliability of the cross-correlation detection is calculated. The reliability effective threshold value and the reference waveform update threshold value are set. The reliability of the cross-correlation coefficient is evaluated so as to determine whether the reference waveform is updated. When the reliability is less than the effective threshold, it is determined that the received signal is invalid, and the ultrasonic signal is re-sent. When the reliability is greater than the update threshold, it is determined that the received signal waveform is highly consistent with the reference waveform. There is no need to update the reference waveform. When the reliability is between the effective threshold and the update threshold, it is determined that the received signal is valid. And the original reference waveform is replaced with the current received signal waveform to realize automatic tracking of the reference waveform. This paper analyzes the two kinds of waveform changes of ultrasonic received signal which may cause ultrasonic transit time error of one waveform period. The waveform changes are continuous envelope deformation and instantaneous envelope distortion. The change of gas flow rate, temperature and pressure will lead to the continuous change of received signal envelope. Spike pulses, random signals and periodic interference may cause instantaneous envelope distortion of the ultrasonic received signal. The instantaneous envelope distortion can be divided into three cases, severe distortion of the main peak, slight distortion of the main peak and non-main peak distortion. The experimental results show that under the influence of different flow velocity, temperature, pressure and noise, the relative error of ultrasonic gas flowmeter is less than ±1.0%. The results meet the measurement requirement of precision level 1.0. The automatic tracking method of reference waveform provides a guarantee for the accuracy and reliability of flow measurement.
first_indexed 2024-04-10T00:04:33Z
format Article
id doaj.art-8356131d73014dc4a6e8826c4b3fa4c9
institution Directory Open Access Journal
issn 1671-251X
language zho
last_indexed 2024-04-10T00:04:33Z
publishDate 2022-04-01
publisher Editorial Department of Industry and Mine Automation
record_format Article
series Gong-kuang zidonghua
spelling doaj.art-8356131d73014dc4a6e8826c4b3fa4c92023-03-17T01:02:52ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2022-04-014843843, 5910.13272/j.issn.1671-251x.2021080082Automatic tracking method of reference waveform of mine ultrasonic gas flowmeterBAI SizhongThe accuracy of mine ultrasonic gas flowmeter needs to be improved. The cross-correlation detection signal has 'signal hopping' phenomenon and affects the measurement precision of ultrasonic transit time. In order to solve the above problems, this paper proposes an automatic tracking method of reference waveform of mine ultrasonic gas flowmeter. While calculating the ultrasonic transit time, the cross-correlation operation is carried out between the ultrasonic reference waveform and the real-time received signal waveform. The reliability of the cross-correlation detection is calculated. The reliability effective threshold value and the reference waveform update threshold value are set. The reliability of the cross-correlation coefficient is evaluated so as to determine whether the reference waveform is updated. When the reliability is less than the effective threshold, it is determined that the received signal is invalid, and the ultrasonic signal is re-sent. When the reliability is greater than the update threshold, it is determined that the received signal waveform is highly consistent with the reference waveform. There is no need to update the reference waveform. When the reliability is between the effective threshold and the update threshold, it is determined that the received signal is valid. And the original reference waveform is replaced with the current received signal waveform to realize automatic tracking of the reference waveform. This paper analyzes the two kinds of waveform changes of ultrasonic received signal which may cause ultrasonic transit time error of one waveform period. The waveform changes are continuous envelope deformation and instantaneous envelope distortion. The change of gas flow rate, temperature and pressure will lead to the continuous change of received signal envelope. Spike pulses, random signals and periodic interference may cause instantaneous envelope distortion of the ultrasonic received signal. The instantaneous envelope distortion can be divided into three cases, severe distortion of the main peak, slight distortion of the main peak and non-main peak distortion. The experimental results show that under the influence of different flow velocity, temperature, pressure and noise, the relative error of ultrasonic gas flowmeter is less than ±1.0%. The results meet the measurement requirement of precision level 1.0. The automatic tracking method of reference waveform provides a guarantee for the accuracy and reliability of flow measurement.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2021080082ultrasonic gas flowmeterpipeline flowtime difference methodtransit timereference waveformautomatic trackingcross-correlation detectionreliability
spellingShingle BAI Sizhong
Automatic tracking method of reference waveform of mine ultrasonic gas flowmeter
Gong-kuang zidonghua
ultrasonic gas flowmeter
pipeline flow
time difference method
transit time
reference waveform
automatic tracking
cross-correlation detection
reliability
title Automatic tracking method of reference waveform of mine ultrasonic gas flowmeter
title_full Automatic tracking method of reference waveform of mine ultrasonic gas flowmeter
title_fullStr Automatic tracking method of reference waveform of mine ultrasonic gas flowmeter
title_full_unstemmed Automatic tracking method of reference waveform of mine ultrasonic gas flowmeter
title_short Automatic tracking method of reference waveform of mine ultrasonic gas flowmeter
title_sort automatic tracking method of reference waveform of mine ultrasonic gas flowmeter
topic ultrasonic gas flowmeter
pipeline flow
time difference method
transit time
reference waveform
automatic tracking
cross-correlation detection
reliability
url http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2021080082
work_keys_str_mv AT baisizhong automatictrackingmethodofreferencewaveformofmineultrasonicgasflowmeter