ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNAN

Ventilating and Air Conditioning system consumes 50-70% of the total energy used in an office building. The cooling load of a building consists of internal cooling load, i.e. loads produce by light, occupants, and heat generating power/appliances; and external cooling load, i.e. loads produce by rad...

Full description

Bibliographic Details
Main Author: Sandra Loekita
Format: Article
Language:English
Published: Petra Christian University 2006-01-01
Series:Civil Engineering Dimension
Subjects:
Online Access:http://puslit2.petra.ac.id/ejournal/index.php/civ/article/view/16465
_version_ 1819135116260147200
author Sandra Loekita
author_facet Sandra Loekita
author_sort Sandra Loekita
collection DOAJ
description Ventilating and Air Conditioning system consumes 50-70% of the total energy used in an office building. The cooling load of a building consists of internal cooling load, i.e. loads produce by light, occupants, and heat generating power/appliances; and external cooling load, i.e. loads produce by radiation, conduction, and ventilation/infiltration through building envelope. To reduce the external cooling load, SNI 03-6389-2000 specifies that the Overall Thermal Transfer Value (OTTV) should be less than or equal to 45 Watt/m². This research supports energy conservation in finding the optimum building envelope design by specifying the Window to Wall Ratio (WWR) which will fulfill the OTTV requirement. Five office buildings in Jakarta, eight story and above are used in this study. The result shows that WWR less than or equal to 0.40 will produce OTTV value that suits the SNI 03-6389-2000 requirement. It is also shown that OTTV value is not the only factor that guarantees energy conservation. Abstract in Bahasa Indonesia : Sistem tata udara menggunakan 50-70% energi dari keseluruhan energi listrik yang digunakan dalam sebuah bangunan gedung perkantoran. Beban pendinginan dari suatu bangunan gedung terdiri dari beban internal, yaitu beban yang ditimbulkan oleh lampu, penghuni serta peralatan lain yang menimbulkan panas dan beban external yaitu panas yang masuk dalam bangunan diakibatkan oleh radiasi matahari, konduksi dan ventilasi/infiltrasi melalui selubung bangunan. Untuk mengurangi beban external, SNI 03-6389-2000 menentukan kriteria disain yaitu Overall Thermal Transfer Value (OTTV) harus lebih kecil atau sama dengan 45 Watt/m². Untuk mempermudah perencanaan untuk mendukung upaya konservasi energi penelitian ini berusaha mencari Window to Wall Ratio (WWR) yang dapat memenuhi OTTV yang disyaratkan. Studi dilakukan pada lima gedung perkantoran di Jakarta, yang memiliki ketinggian lebih dari delapan lantai. Hasil penelitian ini menunjukkan WWR lebih kecil atau sama dengan 0,40 menghasilkan nilai OTTV memenuhi syarat yang ditentukan oleh SNI 03-6389-2000. Ditunjukkan pula bahwa nilai OTTV bukan satu-satunya batasan yang menjamin gedung hemat energi
first_indexed 2024-12-22T10:13:58Z
format Article
id doaj.art-83b646a9b657449c8b048df1e94b592a
institution Directory Open Access Journal
issn 1410-9530
1979-570X
language English
last_indexed 2024-12-22T10:13:58Z
publishDate 2006-01-01
publisher Petra Christian University
record_format Article
series Civil Engineering Dimension
spelling doaj.art-83b646a9b657449c8b048df1e94b592a2022-12-21T18:29:47ZengPetra Christian UniversityCivil Engineering Dimension1410-95301979-570X2006-01-01829398ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNANSandra LoekitaVentilating and Air Conditioning system consumes 50-70% of the total energy used in an office building. The cooling load of a building consists of internal cooling load, i.e. loads produce by light, occupants, and heat generating power/appliances; and external cooling load, i.e. loads produce by radiation, conduction, and ventilation/infiltration through building envelope. To reduce the external cooling load, SNI 03-6389-2000 specifies that the Overall Thermal Transfer Value (OTTV) should be less than or equal to 45 Watt/m². This research supports energy conservation in finding the optimum building envelope design by specifying the Window to Wall Ratio (WWR) which will fulfill the OTTV requirement. Five office buildings in Jakarta, eight story and above are used in this study. The result shows that WWR less than or equal to 0.40 will produce OTTV value that suits the SNI 03-6389-2000 requirement. It is also shown that OTTV value is not the only factor that guarantees energy conservation. Abstract in Bahasa Indonesia : Sistem tata udara menggunakan 50-70% energi dari keseluruhan energi listrik yang digunakan dalam sebuah bangunan gedung perkantoran. Beban pendinginan dari suatu bangunan gedung terdiri dari beban internal, yaitu beban yang ditimbulkan oleh lampu, penghuni serta peralatan lain yang menimbulkan panas dan beban external yaitu panas yang masuk dalam bangunan diakibatkan oleh radiasi matahari, konduksi dan ventilasi/infiltrasi melalui selubung bangunan. Untuk mengurangi beban external, SNI 03-6389-2000 menentukan kriteria disain yaitu Overall Thermal Transfer Value (OTTV) harus lebih kecil atau sama dengan 45 Watt/m². Untuk mempermudah perencanaan untuk mendukung upaya konservasi energi penelitian ini berusaha mencari Window to Wall Ratio (WWR) yang dapat memenuhi OTTV yang disyaratkan. Studi dilakukan pada lima gedung perkantoran di Jakarta, yang memiliki ketinggian lebih dari delapan lantai. Hasil penelitian ini menunjukkan WWR lebih kecil atau sama dengan 0,40 menghasilkan nilai OTTV memenuhi syarat yang ditentukan oleh SNI 03-6389-2000. Ditunjukkan pula bahwa nilai OTTV bukan satu-satunya batasan yang menjamin gedung hemat energihttp://puslit2.petra.ac.id/ejournal/index.php/civ/article/view/16465energy conservationOTTVWWRcooling load.
spellingShingle Sandra Loekita
ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNAN
Civil Engineering Dimension
energy conservation
OTTV
WWR
cooling load.
title ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNAN
title_full ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNAN
title_fullStr ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNAN
title_full_unstemmed ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNAN
title_short ANALISIS KONSERVASI ENERGI MELALUI SELUBUNG BANGUNAN
title_sort analisis konservasi energi melalui selubung bangunan
topic energy conservation
OTTV
WWR
cooling load.
url http://puslit2.petra.ac.id/ejournal/index.php/civ/article/view/16465
work_keys_str_mv AT sandraloekita analisiskonservasienergimelaluiselubungbangunan