A Non-isolated Modified Zeta Converter-fed DC Motor under Load Condition
Abstract In this paper, the steady state performance characteristics of a separately excited DC motor fed by a non-isolated positive output DC-DC converter of high voltage gain Zeta topology are presented. The suggested Zeta converter configuration energized by a DC source is operated in continuous...
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Instituto de Tecnologia do Paraná (Tecpar)
2024-01-01
|
Series: | Brazilian Archives of Biology and Technology |
Subjects: | |
Online Access: | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132024000100606&lng=en&tlng=en |
_version_ | 1797348498791727104 |
---|---|
author | Murali Duraisamy Shruthi Kumar |
author_facet | Murali Duraisamy Shruthi Kumar |
author_sort | Murali Duraisamy |
collection | DOAJ |
description | Abstract In this paper, the steady state performance characteristics of a separately excited DC motor fed by a non-isolated positive output DC-DC converter of high voltage gain Zeta topology are presented. The suggested Zeta converter configuration energized by a DC source is operated in continuous inductor current mode. The DC motor is mechanically coupled with a DC generator. The armature voltage and hence the speed of the motor is controlled by varying the duty ratio (k) of the converter for the given converter input voltage and generator-side load resistance. The proposed DC motor speed control scheme is simulated in MATLAB/SIMULINK platform for performance validation. The various performance measures such as torque, speed, armature current, armature voltage, load current, and efficiency for the motor-generator set are explored. The comparison of voltage gain of existing Zeta topologies and the voltage stress calculation are also illustrated. |
first_indexed | 2024-03-08T12:06:47Z |
format | Article |
id | doaj.art-83c4bbe8297d41f7ad409ce9fa137df6 |
institution | Directory Open Access Journal |
issn | 1678-4324 |
language | English |
last_indexed | 2024-03-08T12:06:47Z |
publishDate | 2024-01-01 |
publisher | Instituto de Tecnologia do Paraná (Tecpar) |
record_format | Article |
series | Brazilian Archives of Biology and Technology |
spelling | doaj.art-83c4bbe8297d41f7ad409ce9fa137df62024-01-23T07:38:21ZengInstituto de Tecnologia do Paraná (Tecpar)Brazilian Archives of Biology and Technology1678-43242024-01-016710.1590/1678-4324-2024230420A Non-isolated Modified Zeta Converter-fed DC Motor under Load ConditionMurali Duraisamyhttps://orcid.org/0000-0002-6890-1687Shruthi Kumarhttps://orcid.org/0000-0002-6383-0461Abstract In this paper, the steady state performance characteristics of a separately excited DC motor fed by a non-isolated positive output DC-DC converter of high voltage gain Zeta topology are presented. The suggested Zeta converter configuration energized by a DC source is operated in continuous inductor current mode. The DC motor is mechanically coupled with a DC generator. The armature voltage and hence the speed of the motor is controlled by varying the duty ratio (k) of the converter for the given converter input voltage and generator-side load resistance. The proposed DC motor speed control scheme is simulated in MATLAB/SIMULINK platform for performance validation. The various performance measures such as torque, speed, armature current, armature voltage, load current, and efficiency for the motor-generator set are explored. The comparison of voltage gain of existing Zeta topologies and the voltage stress calculation are also illustrated.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132024000100606&lng=en&tlng=enContinuous inductor current modeDC motor-generator setDuty ratioMATLAB/SIMULINKPerformance characteristicsZeta topology |
spellingShingle | Murali Duraisamy Shruthi Kumar A Non-isolated Modified Zeta Converter-fed DC Motor under Load Condition Brazilian Archives of Biology and Technology Continuous inductor current mode DC motor-generator set Duty ratio MATLAB/SIMULINK Performance characteristics Zeta topology |
title | A Non-isolated Modified Zeta Converter-fed DC Motor under Load Condition |
title_full | A Non-isolated Modified Zeta Converter-fed DC Motor under Load Condition |
title_fullStr | A Non-isolated Modified Zeta Converter-fed DC Motor under Load Condition |
title_full_unstemmed | A Non-isolated Modified Zeta Converter-fed DC Motor under Load Condition |
title_short | A Non-isolated Modified Zeta Converter-fed DC Motor under Load Condition |
title_sort | non isolated modified zeta converter fed dc motor under load condition |
topic | Continuous inductor current mode DC motor-generator set Duty ratio MATLAB/SIMULINK Performance characteristics Zeta topology |
url | http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1516-89132024000100606&lng=en&tlng=en |
work_keys_str_mv | AT muraliduraisamy anonisolatedmodifiedzetaconverterfeddcmotorunderloadcondition AT shruthikumar anonisolatedmodifiedzetaconverterfeddcmotorunderloadcondition AT muraliduraisamy nonisolatedmodifiedzetaconverterfeddcmotorunderloadcondition AT shruthikumar nonisolatedmodifiedzetaconverterfeddcmotorunderloadcondition |