Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin

Background: The aim of this study was to determine the microtensile bond strength (μTBS) of ceramic and composite computer aided design-computer aided manufacturing (CAD-CAM) blocks bonded to dentin using different adhesive strategies. Materials and Methods: In this in vitro study, 30 crowns of sou...

Full description

Bibliographic Details
Main Authors: Renato Roperto, Anna Akkus, Ozan Akkus, Lisa Lang, Manoel Damiao Sousa-Neto, Sorin Teich, Thiago Soares Porto
Format: Article
Language:English
Published: Wolters Kluwer Medknow Publications 2016-01-01
Series:Dental Research Journal
Subjects:
Online Access:http://www.drjjournal.net/article.asp?issn=1735-3327;year=2016;volume=13;issue=2;spage=117;epage=123;aulast=Roperto
_version_ 1828380355098312704
author Renato Roperto
Anna Akkus
Ozan Akkus
Lisa Lang
Manoel Damiao Sousa-Neto
Sorin Teich
Thiago Soares Porto
author_facet Renato Roperto
Anna Akkus
Ozan Akkus
Lisa Lang
Manoel Damiao Sousa-Neto
Sorin Teich
Thiago Soares Porto
author_sort Renato Roperto
collection DOAJ
description Background: The aim of this study was to determine the microtensile bond strength (μTBS) of ceramic and composite computer aided design-computer aided manufacturing (CAD-CAM) blocks bonded to dentin using different adhesive strategies. Materials and Methods: In this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. Ceramic and composite CAD/CAM blocks, size 14, were sectioned into slices of 3 mm thick. Before bonding, CAD/CAM block surfaces were treated according to the manufacturer′s instructions. Groups were created based on the adhesive strategy used: Group 1 (GI) - conventional resin cement + total-etch adhesive system, Group 2 (GII) - conventional resin cement + self-etch adhesive system, and Group 3 (GIII) - self-adhesive resin cement with no adhesive. Bonded specimens were stored in 100% humidity for 24h at 37΀C, and then sectioned with a slow-speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. Microtensile testing was then conducted using a microtensile tester. μTBS values were expressed in MPa and analyzed by one-way ANOVA with post hoc (Tukey) test at the 5% significance level. Results: Mean values and standard deviations of μTBS (MPa) were 17.68 (±2.71) for GI/ceramic; 17.62 (±3.99) for GI/composite; 13.61 (±6.92) for GII/composite; 12.22 (±4.24) for GII/ceramic; 7.47 (±2.29) for GIII/composite; and 6.48 (±3.10) for GIII/ceramic; ANOVA indicated significant differences among the adhesive modality and block interaction (P < 0.05), and no significant differences among blocks only, except between GI and GII/ceramic. Bond strength of GIII was consistently lower (P < 0.05) than GI and GII groups, regardless the block used. Conclusion: Cementation of CAD/CAM restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used.
first_indexed 2024-12-10T03:55:37Z
format Article
id doaj.art-847ce14a1b5b459c9da5755fa092709c
institution Directory Open Access Journal
issn 1735-3327
2008-0255
language English
last_indexed 2024-12-10T03:55:37Z
publishDate 2016-01-01
publisher Wolters Kluwer Medknow Publications
record_format Article
series Dental Research Journal
spelling doaj.art-847ce14a1b5b459c9da5755fa092709c2022-12-22T02:03:07ZengWolters Kluwer Medknow PublicationsDental Research Journal1735-33272008-02552016-01-0113211712310.4103/1735-3327.178196Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentinRenato RopertoAnna AkkusOzan AkkusLisa LangManoel Damiao Sousa-NetoSorin TeichThiago Soares PortoBackground: The aim of this study was to determine the microtensile bond strength (μTBS) of ceramic and composite computer aided design-computer aided manufacturing (CAD-CAM) blocks bonded to dentin using different adhesive strategies. Materials and Methods: In this in vitro study, 30 crowns of sound freshly extracted human molars were sectioned horizontally 3 mm above the cementoenamel junction to produce flat dentin surfaces. Ceramic and composite CAD/CAM blocks, size 14, were sectioned into slices of 3 mm thick. Before bonding, CAD/CAM block surfaces were treated according to the manufacturer′s instructions. Groups were created based on the adhesive strategy used: Group 1 (GI) - conventional resin cement + total-etch adhesive system, Group 2 (GII) - conventional resin cement + self-etch adhesive system, and Group 3 (GIII) - self-adhesive resin cement with no adhesive. Bonded specimens were stored in 100% humidity for 24h at 37΀C, and then sectioned with a slow-speed diamond saw to obtain 1 mm × 1 mm × 6 mm microsticks. Microtensile testing was then conducted using a microtensile tester. μTBS values were expressed in MPa and analyzed by one-way ANOVA with post hoc (Tukey) test at the 5% significance level. Results: Mean values and standard deviations of μTBS (MPa) were 17.68 (±2.71) for GI/ceramic; 17.62 (±3.99) for GI/composite; 13.61 (±6.92) for GII/composite; 12.22 (±4.24) for GII/ceramic; 7.47 (±2.29) for GIII/composite; and 6.48 (±3.10) for GIII/ceramic; ANOVA indicated significant differences among the adhesive modality and block interaction (P < 0.05), and no significant differences among blocks only, except between GI and GII/ceramic. Bond strength of GIII was consistently lower (P < 0.05) than GI and GII groups, regardless the block used. Conclusion: Cementation of CAD/CAM restorations, either composite or ceramic, can be significantly affected by different adhesive strategies used.http://www.drjjournal.net/article.asp?issn=1735-3327;year=2016;volume=13;issue=2;spage=117;epage=123;aulast=RopertoAdhesionceramiccomposite resincomputer aided design/computer aided manufacturing
spellingShingle Renato Roperto
Anna Akkus
Ozan Akkus
Lisa Lang
Manoel Damiao Sousa-Neto
Sorin Teich
Thiago Soares Porto
Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin
Dental Research Journal
Adhesion
ceramic
composite resin
computer aided design/computer aided manufacturing
title Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin
title_full Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin
title_fullStr Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin
title_full_unstemmed Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin
title_short Effect of different adhesive strategies on microtensile bond strength of computer aided design/computer aided manufacturing blocks bonded to dentin
title_sort effect of different adhesive strategies on microtensile bond strength of computer aided design computer aided manufacturing blocks bonded to dentin
topic Adhesion
ceramic
composite resin
computer aided design/computer aided manufacturing
url http://www.drjjournal.net/article.asp?issn=1735-3327;year=2016;volume=13;issue=2;spage=117;epage=123;aulast=Roperto
work_keys_str_mv AT renatoroperto effectofdifferentadhesivestrategiesonmicrotensilebondstrengthofcomputeraideddesigncomputeraidedmanufacturingblocksbondedtodentin
AT annaakkus effectofdifferentadhesivestrategiesonmicrotensilebondstrengthofcomputeraideddesigncomputeraidedmanufacturingblocksbondedtodentin
AT ozanakkus effectofdifferentadhesivestrategiesonmicrotensilebondstrengthofcomputeraideddesigncomputeraidedmanufacturingblocksbondedtodentin
AT lisalang effectofdifferentadhesivestrategiesonmicrotensilebondstrengthofcomputeraideddesigncomputeraidedmanufacturingblocksbondedtodentin
AT manoeldamiaosousaneto effectofdifferentadhesivestrategiesonmicrotensilebondstrengthofcomputeraideddesigncomputeraidedmanufacturingblocksbondedtodentin
AT sorinteich effectofdifferentadhesivestrategiesonmicrotensilebondstrengthofcomputeraideddesigncomputeraidedmanufacturingblocksbondedtodentin
AT thiagosoaresporto effectofdifferentadhesivestrategiesonmicrotensilebondstrengthofcomputeraideddesigncomputeraidedmanufacturingblocksbondedtodentin