Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.

Voluntary deep inspiration breath hold technique (vDIBH) is considered as the key to achieving the widest cardiac sparing in whole breast irradiation. Several techniques have been implemented to achieve a reproducible, fast and friendly treatment. The aim of the present study is to implement vDIBH u...

Full description

Bibliographic Details
Main Authors: Edy Ippolito, Michele Fiore, Alessia Di Donato, Sonia Silipigni, Carla Rinaldi, Patrizia Cornacchione, Erminia Infusino, Cristina Di Venanzio, Carlo Greco, Lucio Trodella, Sara Ramella, Rolando Maria D'Angelillo
Format: Article
Language:English
Published: Public Library of Science (PLoS) 2018-01-01
Series:PLoS ONE
Online Access:http://europepmc.org/articles/PMC5945040?pdf=render
_version_ 1818036144050274304
author Edy Ippolito
Michele Fiore
Alessia Di Donato
Sonia Silipigni
Carla Rinaldi
Patrizia Cornacchione
Erminia Infusino
Cristina Di Venanzio
Carlo Greco
Lucio Trodella
Sara Ramella
Rolando Maria D'Angelillo
author_facet Edy Ippolito
Michele Fiore
Alessia Di Donato
Sonia Silipigni
Carla Rinaldi
Patrizia Cornacchione
Erminia Infusino
Cristina Di Venanzio
Carlo Greco
Lucio Trodella
Sara Ramella
Rolando Maria D'Angelillo
author_sort Edy Ippolito
collection DOAJ
description Voluntary deep inspiration breath hold technique (vDIBH) is considered as the key to achieving the widest cardiac sparing in whole breast irradiation. Several techniques have been implemented to achieve a reproducible, fast and friendly treatment. The aim of the present study is to implement vDIBH using the ExacTrac (BrainLAB AG, Germany) monitoring system.Women with left-sided breast cancer, younger than 50 years or with cardiac disease, underwent whole breast RT with vDIBH using the ExacTrac (BrainLAB AG, Germany) monitoring system. Simulations were performed with patients positioned supine on a breast board with both arms raised above the head. Five optical markers were placed on the skin around the border of the left breast gland and their position was referenced with ink marking. Each patient received a training session to find the individual deep inspiration level. Finally, a vDIBH CT was taken. All patients were also studied in free breathing (FB) in order to compare the dose distribution for PTV, heart and left anterior descending coronary artery (LAD). Pre-treatment verification was carried out through the ExacTrac (BrainLAB AG, Germany) system and verified with electronic portal imaging (EPI). Moreover, daily real time EPIs in during modality (captured during the beam delivery) were taken in order to check the reproducibility.34 patients have been evaluated and 30 were eligible for vDIBH. Most patients showed small setup errors during the treatment course of below 5 mm in 94.9% of the recorded fields. Mean Displacement was less in cranio-caudal direction. Mean intra-fraction displacement was below 3 mm in all directions. vDIBH plans provided better cardiac dosimetry.vDIBH technique using ExacTrac (BrainLAB AG, Germany) monitoring system was applied with good reproducibility.
first_indexed 2024-12-10T07:06:16Z
format Article
id doaj.art-84a5cbce51e64c4dbd4f322cea3ecf6b
institution Directory Open Access Journal
issn 1932-6203
language English
last_indexed 2024-12-10T07:06:16Z
publishDate 2018-01-01
publisher Public Library of Science (PLoS)
record_format Article
series PLoS ONE
spelling doaj.art-84a5cbce51e64c4dbd4f322cea3ecf6b2022-12-22T01:58:10ZengPublic Library of Science (PLoS)PLoS ONE1932-62032018-01-01135e019550610.1371/journal.pone.0195506Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.Edy IppolitoMichele FioreAlessia Di DonatoSonia SilipigniCarla RinaldiPatrizia CornacchioneErminia InfusinoCristina Di VenanzioCarlo GrecoLucio TrodellaSara RamellaRolando Maria D'AngelilloVoluntary deep inspiration breath hold technique (vDIBH) is considered as the key to achieving the widest cardiac sparing in whole breast irradiation. Several techniques have been implemented to achieve a reproducible, fast and friendly treatment. The aim of the present study is to implement vDIBH using the ExacTrac (BrainLAB AG, Germany) monitoring system.Women with left-sided breast cancer, younger than 50 years or with cardiac disease, underwent whole breast RT with vDIBH using the ExacTrac (BrainLAB AG, Germany) monitoring system. Simulations were performed with patients positioned supine on a breast board with both arms raised above the head. Five optical markers were placed on the skin around the border of the left breast gland and their position was referenced with ink marking. Each patient received a training session to find the individual deep inspiration level. Finally, a vDIBH CT was taken. All patients were also studied in free breathing (FB) in order to compare the dose distribution for PTV, heart and left anterior descending coronary artery (LAD). Pre-treatment verification was carried out through the ExacTrac (BrainLAB AG, Germany) system and verified with electronic portal imaging (EPI). Moreover, daily real time EPIs in during modality (captured during the beam delivery) were taken in order to check the reproducibility.34 patients have been evaluated and 30 were eligible for vDIBH. Most patients showed small setup errors during the treatment course of below 5 mm in 94.9% of the recorded fields. Mean Displacement was less in cranio-caudal direction. Mean intra-fraction displacement was below 3 mm in all directions. vDIBH plans provided better cardiac dosimetry.vDIBH technique using ExacTrac (BrainLAB AG, Germany) monitoring system was applied with good reproducibility.http://europepmc.org/articles/PMC5945040?pdf=render
spellingShingle Edy Ippolito
Michele Fiore
Alessia Di Donato
Sonia Silipigni
Carla Rinaldi
Patrizia Cornacchione
Erminia Infusino
Cristina Di Venanzio
Carlo Greco
Lucio Trodella
Sara Ramella
Rolando Maria D'Angelillo
Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.
PLoS ONE
title Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.
title_full Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.
title_fullStr Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.
title_full_unstemmed Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.
title_short Implementation of a voluntary deep inspiration breath hold technique (vDIBH) using BrainLab ExacTrac infrared optical tracking system.
title_sort implementation of a voluntary deep inspiration breath hold technique vdibh using brainlab exactrac infrared optical tracking system
url http://europepmc.org/articles/PMC5945040?pdf=render
work_keys_str_mv AT edyippolito implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT michelefiore implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT alessiadidonato implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT soniasilipigni implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT carlarinaldi implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT patriziacornacchione implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT erminiainfusino implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT cristinadivenanzio implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT carlogreco implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT luciotrodella implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT sararamella implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem
AT rolandomariadangelillo implementationofavoluntarydeepinspirationbreathholdtechniquevdibhusingbrainlabexactracinfraredopticaltrackingsystem