Goldmann tonometer error correcting prism: clinical evaluation
Sean McCafferty,1–3 Garrett Lim,2 William Duncan,2 Eniko T Enikov,4 Jim Schwiegerling,1 Jason Levine,1,3 Corin Kew3 1Department of Ophthalmology, College of Optical Science, University of Arizona, 2Intuor Technologies, 3Arizona Eye Consultants, 4Department of Aerospace and Mechanical, Col...
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Dove Medical Press
2017-05-01
|
Series: | Clinical Ophthalmology |
Subjects: | |
Online Access: | https://www.dovepress.com/goldmann-tonometer-error-correcting-prism-clinical-evaluation-peer-reviewed-article-OPTH |
_version_ | 1818897799272464384 |
---|---|
author | McCafferty S Lim G Duncan W Enikov ET Schwiegerling J Levine J Kew C |
author_facet | McCafferty S Lim G Duncan W Enikov ET Schwiegerling J Levine J Kew C |
author_sort | McCafferty S |
collection | DOAJ |
description | Sean McCafferty,1–3 Garrett Lim,2 William Duncan,2 Eniko T Enikov,4 Jim Schwiegerling,1 Jason Levine,1,3 Corin Kew3 1Department of Ophthalmology, College of Optical Science, University of Arizona, 2Intuor Technologies, 3Arizona Eye Consultants, 4Department of Aerospace and Mechanical, College of Engineering, University of Arizona, Tucson, AZ, USA Purpose: Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics.Methods: A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness, stiffness, curvature, and tear film adhesion force. A comparative clinical study of 109 eyes measured IOP with CATS and Goldmann prisms. The IOP measurement differences between the CATS and Goldmann prisms were correlated to corneal thickness, hysteresis, and curvature.Results: The CATS tonometer prism in correcting for Goldmann central corneal thickness (CCT) error demonstrated a reduction to <±2 mmHg in 97% of a standard CCT population. This compares to only 54% with CCT error <±2 mmHg using the Goldmann prism. Equal reductions of ~50% in errors due to corneal rigidity and curvature were also demonstrated.Conclusion: The results validate the CATS prism’s improved accuracy and expected reduced sensitivity to Goldmann errors without IOP bias as predicted by mathematical modeling. The CATS replacement for the Goldmann prism does not change Goldmann measurement technique or interpretation. Keywords: glaucoma, tonometry, Goldmann, IOP, intraocular pressure, appalnation tonometer, corneal biomechanics, CATS tonometer, CCT, central corneal thickness, tonometer error |
first_indexed | 2024-12-19T19:21:55Z |
format | Article |
id | doaj.art-84eac367305e4194b52b1dd6bd1187bd |
institution | Directory Open Access Journal |
issn | 1177-5483 |
language | English |
last_indexed | 2024-12-19T19:21:55Z |
publishDate | 2017-05-01 |
publisher | Dove Medical Press |
record_format | Article |
series | Clinical Ophthalmology |
spelling | doaj.art-84eac367305e4194b52b1dd6bd1187bd2022-12-21T20:08:58ZengDove Medical PressClinical Ophthalmology1177-54832017-05-01Volume 1183584032666Goldmann tonometer error correcting prism: clinical evaluationMcCafferty SLim GDuncan WEnikov ETSchwiegerling JLevine JKew CSean McCafferty,1–3 Garrett Lim,2 William Duncan,2 Eniko T Enikov,4 Jim Schwiegerling,1 Jason Levine,1,3 Corin Kew3 1Department of Ophthalmology, College of Optical Science, University of Arizona, 2Intuor Technologies, 3Arizona Eye Consultants, 4Department of Aerospace and Mechanical, College of Engineering, University of Arizona, Tucson, AZ, USA Purpose: Clinically evaluate a modified applanating surface Goldmann tonometer prism designed to substantially negate errors due to patient variability in biomechanics.Methods: A modified Goldmann prism with a correcting applanation tonometry surface (CATS) was mathematically optimized to minimize the intraocular pressure (IOP) measurement error due to patient variability in corneal thickness, stiffness, curvature, and tear film adhesion force. A comparative clinical study of 109 eyes measured IOP with CATS and Goldmann prisms. The IOP measurement differences between the CATS and Goldmann prisms were correlated to corneal thickness, hysteresis, and curvature.Results: The CATS tonometer prism in correcting for Goldmann central corneal thickness (CCT) error demonstrated a reduction to <±2 mmHg in 97% of a standard CCT population. This compares to only 54% with CCT error <±2 mmHg using the Goldmann prism. Equal reductions of ~50% in errors due to corneal rigidity and curvature were also demonstrated.Conclusion: The results validate the CATS prism’s improved accuracy and expected reduced sensitivity to Goldmann errors without IOP bias as predicted by mathematical modeling. The CATS replacement for the Goldmann prism does not change Goldmann measurement technique or interpretation. Keywords: glaucoma, tonometry, Goldmann, IOP, intraocular pressure, appalnation tonometer, corneal biomechanics, CATS tonometer, CCT, central corneal thickness, tonometer error https://www.dovepress.com/goldmann-tonometer-error-correcting-prism-clinical-evaluation-peer-reviewed-article-OPTHGlaucomaintraocular pressuretonometry |
spellingShingle | McCafferty S Lim G Duncan W Enikov ET Schwiegerling J Levine J Kew C Goldmann tonometer error correcting prism: clinical evaluation Clinical Ophthalmology Glaucoma intraocular pressure tonometry |
title | Goldmann tonometer error correcting prism: clinical evaluation |
title_full | Goldmann tonometer error correcting prism: clinical evaluation |
title_fullStr | Goldmann tonometer error correcting prism: clinical evaluation |
title_full_unstemmed | Goldmann tonometer error correcting prism: clinical evaluation |
title_short | Goldmann tonometer error correcting prism: clinical evaluation |
title_sort | goldmann tonometer error correcting prism clinical evaluation |
topic | Glaucoma intraocular pressure tonometry |
url | https://www.dovepress.com/goldmann-tonometer-error-correcting-prism-clinical-evaluation-peer-reviewed-article-OPTH |
work_keys_str_mv | AT mccaffertys goldmanntonometererrorcorrectingprismclinicalevaluation AT limg goldmanntonometererrorcorrectingprismclinicalevaluation AT duncanw goldmanntonometererrorcorrectingprismclinicalevaluation AT enikovet goldmanntonometererrorcorrectingprismclinicalevaluation AT schwiegerlingj goldmanntonometererrorcorrectingprismclinicalevaluation AT levinej goldmanntonometererrorcorrectingprismclinicalevaluation AT kewc goldmanntonometererrorcorrectingprismclinicalevaluation |