DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD

Objective: To determine the diagnostic accuracy of Ret-He in detecting IDA, keep ingserum ferritin as goldstandard Study Design: Cross sectional study. Place and Duration of Study: Department of Haematology, AFIP Rawalpindi, from Jan to Jul 2017. Methodology: Study involved 165 female patie...

Full description

Bibliographic Details
Main Authors: Nabeela Khan, Chaudhry Altaf, Hamid Saeed Malik, Zunera Sajjad, Ayesha Khurshid, Muhammad Tahir Khadim
Format: Article
Language:English
Published: Army Medical College Rawalpindi 2019-10-01
Series:Pakistan Armed Forces Medical Journal
Subjects:
Online Access:https://www.pafmj.org/index.php/PAFMJ/article/view/3404/2379
_version_ 1819014958533312512
author Nabeela Khan
Chaudhry Altaf
Hamid Saeed Malik
Zunera Sajjad
Ayesha Khurshid
Muhammad Tahir Khadim
author_facet Nabeela Khan
Chaudhry Altaf
Hamid Saeed Malik
Zunera Sajjad
Ayesha Khurshid
Muhammad Tahir Khadim
author_sort Nabeela Khan
collection DOAJ
description Objective: To determine the diagnostic accuracy of Ret-He in detecting IDA, keep ingserum ferritin as goldstandard Study Design: Cross sectional study. Place and Duration of Study: Department of Haematology, AFIP Rawalpindi, from Jan to Jul 2017. Methodology: Study involved 165 female patients who presented with anemia (hemoglobin <11g/dl). Ret-He was determined having a level of <27.8 pg/L as diagnostic of IDA. Diagnosis of IDA was confirmed on serum ferritin level <11 ng/ml taking it as gold standard. Accordingly, diagnostic accuracy of Ret-He was determined considering low serum ferritin level as gold standard. Results: The mean age of the patients was 27.52 ± 13.57 years. Mean hemoglobin level was 9.17 ± 1.59 g/dl while mean serum ferritin level was 15.20 ± 12.89 ng/ml. Ret-He ranged from 11.0 pg/L to 39.4 pg/L with a mean of 23.34 ± 8.21 pg/L. IDA on the basis of serum ferritin level was diagnosed in 75 (45.5%) patients while Ret-He labeled IDA in 85 (51.5%) patients. When cross-tabulated, there were 70 TP, 15 FP, 5 FN and 75 TN cases which yielded 93.33% sensitivity, 83.33% specificity, 87.88% accuracy, 82.35% PPV and 93.75% NPV for Ret-He in diagnosing IDA keeping serum ferritin as gold standard. Thus the optimal cut-off value of Ret-He was found to be <27.6 pg/L which gave 93.33% sensitivity and 83.33% specificity in detecting IDA keeping serum ferritin as gold standard. Conclusion: Ret-He was found as fast and reliable technique to diagnose IDA in female population. However, further studies are required for confirmation of its efficacy.
first_indexed 2024-12-21T02:24:07Z
format Article
id doaj.art-84f63bc46de0419eb5b1119374074f31
institution Directory Open Access Journal
issn 0030-9648
2411-8842
language English
last_indexed 2024-12-21T02:24:07Z
publishDate 2019-10-01
publisher Army Medical College Rawalpindi
record_format Article
series Pakistan Armed Forces Medical Journal
spelling doaj.art-84f63bc46de0419eb5b1119374074f312022-12-21T19:19:02ZengArmy Medical College RawalpindiPakistan Armed Forces Medical Journal0030-96482411-88422019-10-0169510101014DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARDNabeela Khan0Chaudhry Altaf1Hamid Saeed Malik2Zunera Sajjad3Ayesha Khurshid4Muhammad Tahir Khadim5Armed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanObjective: To determine the diagnostic accuracy of Ret-He in detecting IDA, keep ingserum ferritin as goldstandard Study Design: Cross sectional study. Place and Duration of Study: Department of Haematology, AFIP Rawalpindi, from Jan to Jul 2017. Methodology: Study involved 165 female patients who presented with anemia (hemoglobin <11g/dl). Ret-He was determined having a level of <27.8 pg/L as diagnostic of IDA. Diagnosis of IDA was confirmed on serum ferritin level <11 ng/ml taking it as gold standard. Accordingly, diagnostic accuracy of Ret-He was determined considering low serum ferritin level as gold standard. Results: The mean age of the patients was 27.52 ± 13.57 years. Mean hemoglobin level was 9.17 ± 1.59 g/dl while mean serum ferritin level was 15.20 ± 12.89 ng/ml. Ret-He ranged from 11.0 pg/L to 39.4 pg/L with a mean of 23.34 ± 8.21 pg/L. IDA on the basis of serum ferritin level was diagnosed in 75 (45.5%) patients while Ret-He labeled IDA in 85 (51.5%) patients. When cross-tabulated, there were 70 TP, 15 FP, 5 FN and 75 TN cases which yielded 93.33% sensitivity, 83.33% specificity, 87.88% accuracy, 82.35% PPV and 93.75% NPV for Ret-He in diagnosing IDA keeping serum ferritin as gold standard. Thus the optimal cut-off value of Ret-He was found to be <27.6 pg/L which gave 93.33% sensitivity and 83.33% specificity in detecting IDA keeping serum ferritin as gold standard. Conclusion: Ret-He was found as fast and reliable technique to diagnose IDA in female population. However, further studies are required for confirmation of its efficacy.https://www.pafmj.org/index.php/PAFMJ/article/view/3404/2379diagnostic accuracyiron deficiency anemiareticulocyte haemoglobin equivalent (ret-he)
spellingShingle Nabeela Khan
Chaudhry Altaf
Hamid Saeed Malik
Zunera Sajjad
Ayesha Khurshid
Muhammad Tahir Khadim
DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD
Pakistan Armed Forces Medical Journal
diagnostic accuracy
iron deficiency anemia
reticulocyte haemoglobin equivalent (ret-he)
title DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD
title_full DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD
title_fullStr DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD
title_full_unstemmed DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD
title_short DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD
title_sort diagnostic accuracy of reticulocyte haemoglobin equivalent rethe in detecting iron deficiency anaemia keeping serum ferritin as gold standard
topic diagnostic accuracy
iron deficiency anemia
reticulocyte haemoglobin equivalent (ret-he)
url https://www.pafmj.org/index.php/PAFMJ/article/view/3404/2379
work_keys_str_mv AT nabeelakhan diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard
AT chaudhryaltaf diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard
AT hamidsaeedmalik diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard
AT zunerasajjad diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard
AT ayeshakhurshid diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard
AT muhammadtahirkhadim diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard