DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD
Objective: To determine the diagnostic accuracy of Ret-He in detecting IDA, keep ingserum ferritin as goldstandard Study Design: Cross sectional study. Place and Duration of Study: Department of Haematology, AFIP Rawalpindi, from Jan to Jul 2017. Methodology: Study involved 165 female patie...
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Army Medical College Rawalpindi
2019-10-01
|
Series: | Pakistan Armed Forces Medical Journal |
Subjects: | |
Online Access: | https://www.pafmj.org/index.php/PAFMJ/article/view/3404/2379 |
_version_ | 1819014958533312512 |
---|---|
author | Nabeela Khan Chaudhry Altaf Hamid Saeed Malik Zunera Sajjad Ayesha Khurshid Muhammad Tahir Khadim |
author_facet | Nabeela Khan Chaudhry Altaf Hamid Saeed Malik Zunera Sajjad Ayesha Khurshid Muhammad Tahir Khadim |
author_sort | Nabeela Khan |
collection | DOAJ |
description | Objective: To determine the diagnostic accuracy of Ret-He in detecting IDA, keep ingserum ferritin as goldstandard
Study Design: Cross sectional study.
Place and Duration of Study: Department of Haematology, AFIP Rawalpindi, from Jan to Jul 2017.
Methodology: Study involved 165 female patients who presented with anemia (hemoglobin <11g/dl). Ret-He was determined having a level of <27.8 pg/L as diagnostic of IDA. Diagnosis of IDA was confirmed on serum ferritin level <11 ng/ml taking it as gold standard. Accordingly, diagnostic accuracy of Ret-He was determined considering low serum ferritin level as gold standard.
Results: The mean age of the patients was 27.52 ± 13.57 years. Mean hemoglobin level was 9.17 ± 1.59 g/dl while mean serum ferritin level was 15.20 ± 12.89 ng/ml. Ret-He ranged from 11.0 pg/L to 39.4 pg/L with a mean of 23.34 ± 8.21 pg/L. IDA on the basis of serum ferritin level was diagnosed in 75 (45.5%) patients while Ret-He labeled IDA in 85 (51.5%) patients. When cross-tabulated, there were 70 TP, 15 FP, 5 FN and 75 TN cases which yielded 93.33% sensitivity, 83.33% specificity, 87.88% accuracy, 82.35% PPV and 93.75% NPV for Ret-He in diagnosing IDA keeping serum ferritin as gold standard. Thus the optimal cut-off value of Ret-He was found to be <27.6 pg/L which gave 93.33% sensitivity and 83.33% specificity in detecting IDA keeping serum ferritin as gold standard.
Conclusion: Ret-He was found as fast and reliable technique to diagnose IDA in female population. However, further studies are required for confirmation of its efficacy. |
first_indexed | 2024-12-21T02:24:07Z |
format | Article |
id | doaj.art-84f63bc46de0419eb5b1119374074f31 |
institution | Directory Open Access Journal |
issn | 0030-9648 2411-8842 |
language | English |
last_indexed | 2024-12-21T02:24:07Z |
publishDate | 2019-10-01 |
publisher | Army Medical College Rawalpindi |
record_format | Article |
series | Pakistan Armed Forces Medical Journal |
spelling | doaj.art-84f63bc46de0419eb5b1119374074f312022-12-21T19:19:02ZengArmy Medical College RawalpindiPakistan Armed Forces Medical Journal0030-96482411-88422019-10-0169510101014DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARDNabeela Khan0Chaudhry Altaf1Hamid Saeed Malik2Zunera Sajjad3Ayesha Khurshid4Muhammad Tahir Khadim5Armed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanArmed Forces Institute of Pathology/National University of Medical Sciences (NUMS) Rawalpindi PakistanObjective: To determine the diagnostic accuracy of Ret-He in detecting IDA, keep ingserum ferritin as goldstandard Study Design: Cross sectional study. Place and Duration of Study: Department of Haematology, AFIP Rawalpindi, from Jan to Jul 2017. Methodology: Study involved 165 female patients who presented with anemia (hemoglobin <11g/dl). Ret-He was determined having a level of <27.8 pg/L as diagnostic of IDA. Diagnosis of IDA was confirmed on serum ferritin level <11 ng/ml taking it as gold standard. Accordingly, diagnostic accuracy of Ret-He was determined considering low serum ferritin level as gold standard. Results: The mean age of the patients was 27.52 ± 13.57 years. Mean hemoglobin level was 9.17 ± 1.59 g/dl while mean serum ferritin level was 15.20 ± 12.89 ng/ml. Ret-He ranged from 11.0 pg/L to 39.4 pg/L with a mean of 23.34 ± 8.21 pg/L. IDA on the basis of serum ferritin level was diagnosed in 75 (45.5%) patients while Ret-He labeled IDA in 85 (51.5%) patients. When cross-tabulated, there were 70 TP, 15 FP, 5 FN and 75 TN cases which yielded 93.33% sensitivity, 83.33% specificity, 87.88% accuracy, 82.35% PPV and 93.75% NPV for Ret-He in diagnosing IDA keeping serum ferritin as gold standard. Thus the optimal cut-off value of Ret-He was found to be <27.6 pg/L which gave 93.33% sensitivity and 83.33% specificity in detecting IDA keeping serum ferritin as gold standard. Conclusion: Ret-He was found as fast and reliable technique to diagnose IDA in female population. However, further studies are required for confirmation of its efficacy.https://www.pafmj.org/index.php/PAFMJ/article/view/3404/2379diagnostic accuracyiron deficiency anemiareticulocyte haemoglobin equivalent (ret-he) |
spellingShingle | Nabeela Khan Chaudhry Altaf Hamid Saeed Malik Zunera Sajjad Ayesha Khurshid Muhammad Tahir Khadim DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD Pakistan Armed Forces Medical Journal diagnostic accuracy iron deficiency anemia reticulocyte haemoglobin equivalent (ret-he) |
title | DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD |
title_full | DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD |
title_fullStr | DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD |
title_full_unstemmed | DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD |
title_short | DIAGNOSTIC ACCURACY OF RETICULOCYTE HAEMOGLOBIN EQUIVALENT (RETHE) IN DETECTING IRON DEFICIENCY ANAEMIA KEEPING SERUM FERRITIN AS GOLD STANDARD |
title_sort | diagnostic accuracy of reticulocyte haemoglobin equivalent rethe in detecting iron deficiency anaemia keeping serum ferritin as gold standard |
topic | diagnostic accuracy iron deficiency anemia reticulocyte haemoglobin equivalent (ret-he) |
url | https://www.pafmj.org/index.php/PAFMJ/article/view/3404/2379 |
work_keys_str_mv | AT nabeelakhan diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard AT chaudhryaltaf diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard AT hamidsaeedmalik diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard AT zunerasajjad diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard AT ayeshakhurshid diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard AT muhammadtahirkhadim diagnosticaccuracyofreticulocytehaemoglobinequivalentretheindetectingirondeficiencyanaemiakeepingserumferritinasgoldstandard |