Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed Type

In this work, the enthalpy potential theory is used in conjunction with a formula derived by Uchida and a set of data available on the cooling tower of Baghdad international airport to predict the thermal performance of a mechanical draft counter flow cooling tower of closed type.Computer calculati...

Full description

Bibliographic Details
Main Authors: Nabil S. Sharif, Wisam K. Hussam, Wafa’a A. Makki
Format: Article
Language:Arabic
Published: Mustansiriyah University/College of Engineering 2005-12-01
Series:Journal of Engineering and Sustainable Development
Subjects:
.
Online Access:https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1821
_version_ 1798022916295622656
author Nabil S. Sharif
Wisam K. Hussam
Wafa’a A. Makki
author_facet Nabil S. Sharif
Wisam K. Hussam
Wafa’a A. Makki
author_sort Nabil S. Sharif
collection DOAJ
description In this work, the enthalpy potential theory is used in conjunction with a formula derived by Uchida and a set of data available on the cooling tower of Baghdad international airport to predict the thermal performance of a mechanical draft counter flow cooling tower of closed type.Computer calculations are made to determine the number of transfer units, water-cooling range and tower capacity. The computer results are presented in graphical form as performance curves showing the predictable thermal performance of the tower under different conditions of air inlet wet bulb temperature and water-to-air flow ratio, when the load on the tower, denoted by the water inlet temperature, remains unchanged. The results indicated that the performance of the tower and hence its capacity are affected by the air inlet wet bulb temperature and the water-to-air flow ratio. They face a considerable decline with increase of air inlet wet bulb temperature and with increase of water-to-air flow ratio too. Then, the decline with increase of air inlet wet bulb temperature reduces with increase of water-to-air flow ratio. The agreement of the present results with results of the others and with measurement would give a sufficient support to the analysis adopted in this work.
first_indexed 2024-04-11T17:37:50Z
format Article
id doaj.art-85019a09fa5846ef92e3e40cafcd65d7
institution Directory Open Access Journal
issn 2520-0917
2520-0925
language Arabic
last_indexed 2024-04-11T17:37:50Z
publishDate 2005-12-01
publisher Mustansiriyah University/College of Engineering
record_format Article
series Journal of Engineering and Sustainable Development
spelling doaj.art-85019a09fa5846ef92e3e40cafcd65d72022-12-22T04:11:34ZaraMustansiriyah University/College of EngineeringJournal of Engineering and Sustainable Development2520-09172520-09252005-12-0194Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed TypeNabil S. Sharif0Wisam K. Hussam1Wafa’a A. Makki2Educational Technology Department, University of Technology, Baghdad, IraqEducational Technology Department, University of Technology, Baghdad, IraqEducational Technology Department, University of Technology, Baghdad, Iraq In this work, the enthalpy potential theory is used in conjunction with a formula derived by Uchida and a set of data available on the cooling tower of Baghdad international airport to predict the thermal performance of a mechanical draft counter flow cooling tower of closed type.Computer calculations are made to determine the number of transfer units, water-cooling range and tower capacity. The computer results are presented in graphical form as performance curves showing the predictable thermal performance of the tower under different conditions of air inlet wet bulb temperature and water-to-air flow ratio, when the load on the tower, denoted by the water inlet temperature, remains unchanged. The results indicated that the performance of the tower and hence its capacity are affected by the air inlet wet bulb temperature and the water-to-air flow ratio. They face a considerable decline with increase of air inlet wet bulb temperature and with increase of water-to-air flow ratio too. Then, the decline with increase of air inlet wet bulb temperature reduces with increase of water-to-air flow ratio. The agreement of the present results with results of the others and with measurement would give a sufficient support to the analysis adopted in this work. https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1821.
spellingShingle Nabil S. Sharif
Wisam K. Hussam
Wafa’a A. Makki
Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed Type
Journal of Engineering and Sustainable Development
.
title Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed Type
title_full Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed Type
title_fullStr Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed Type
title_full_unstemmed Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed Type
title_short Predicting the Thermal Performance of a Mechanical Draft Counter Flow Cooling Tower of Closed Type
title_sort predicting the thermal performance of a mechanical draft counter flow cooling tower of closed type
topic .
url https://jeasd.uomustansiriyah.edu.iq/index.php/jeasd/article/view/1821
work_keys_str_mv AT nabilssharif predictingthethermalperformanceofamechanicaldraftcounterflowcoolingtowerofclosedtype
AT wisamkhussam predictingthethermalperformanceofamechanicaldraftcounterflowcoolingtowerofclosedtype
AT wafaaamakki predictingthethermalperformanceofamechanicaldraftcounterflowcoolingtowerofclosedtype