Study on neutral axis location of common bolts of flush end-plate connections

The external load eccentricity and the end-plate thickness were employed as the research parameters, and experimental studies on the tensile properties of the bolts with flush end-plate in the beam-column joints was conducted under the action of eccentric pulling force (group A) or pure bending mome...

Full description

Bibliographic Details
Main Authors: Anlian Wang, Zhiwen Zhang, Jialong Ji, Yan Liu
Format: Article
Language:English
Published: Elsevier 2022-12-01
Series:Results in Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S259012302200353X