Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry

Although 17β-estradiol (E2) deficiency has been linked to the development of osteoarthritis (OA) in middle-aged women, there are few studies relating other estrogens and estrogen metabolites (EMs) to this condition. We developed a high-perf...

Full description

Bibliographic Details
Main Authors: W.L. Gao, L.S. Wu, J.H. Zi, B. Wu, Y.Z. Li, Y.C. Song, D.Z. Cai
Format: Article
Language:English
Published: Associação Brasileira de Divulgação Científica 2015-02-01
Series:Brazilian Journal of Medical and Biological Research
Subjects:
Online Access:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2015000200146&lng=en&tlng=en
_version_ 1817986685068115968
author W.L. Gao
L.S. Wu
J.H. Zi
B. Wu
Y.Z. Li
Y.C. Song
D.Z. Cai
author_facet W.L. Gao
L.S. Wu
J.H. Zi
B. Wu
Y.Z. Li
Y.C. Song
D.Z. Cai
author_sort W.L. Gao
collection DOAJ
description Although 17β-estradiol (E2) deficiency has been linked to the development of osteoarthritis (OA) in middle-aged women, there are few studies relating other estrogens and estrogen metabolites (EMs) to this condition. We developed a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method to measure the levels of six EMs (i.e., estrone, E2, estriol, 2-hydroxyestrone, 2-hydroxyestradiol, and 16a-hydroxyestrone) in healthy pre- and postmenopausal women and women with OA. This method had a precision ranging from 1.1 to 3.1% and a detection limit ranging from 10 to 15 pg. Compared to healthy women, serum-free E2 was lower in the luteal and postmenopausal phases in women with OA, and total serum E2 was lower in postmenopausal women with OA. Moreover, compared to healthy women, total serum 2-hydroxyestradiol was higher in postmenopausal women with OA and total serum 2-hydroxyestrone was lower in both the luteal and follicular phases in women with OA. In conclusion, our HPLC-ESI-MS/MS method allowed the measurement of multiple biochemical targets in a single assay, and, given its increased cost-effectiveness, simplicity, and speed relative to previous methods, this method is suitable for clinical studies.
first_indexed 2024-04-14T00:12:25Z
format Article
id doaj.art-85196ea0aa47459cbba02130f399f7fa
institution Directory Open Access Journal
issn 1414-431X
language English
last_indexed 2024-04-14T00:12:25Z
publishDate 2015-02-01
publisher Associação Brasileira de Divulgação Científica
record_format Article
series Brazilian Journal of Medical and Biological Research
spelling doaj.art-85196ea0aa47459cbba02130f399f7fa2022-12-22T02:23:16ZengAssociação Brasileira de Divulgação CientíficaBrazilian Journal of Medical and Biological Research1414-431X2015-02-0148214615310.1590/1414-431X20144129S0100-879X2015000200146Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometryW.L. GaoL.S. WuJ.H. ZiB. WuY.Z. LiY.C. SongD.Z. CaiAlthough 17β-estradiol (E2) deficiency has been linked to the development of osteoarthritis (OA) in middle-aged women, there are few studies relating other estrogens and estrogen metabolites (EMs) to this condition. We developed a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method to measure the levels of six EMs (i.e., estrone, E2, estriol, 2-hydroxyestrone, 2-hydroxyestradiol, and 16a-hydroxyestrone) in healthy pre- and postmenopausal women and women with OA. This method had a precision ranging from 1.1 to 3.1% and a detection limit ranging from 10 to 15 pg. Compared to healthy women, serum-free E2 was lower in the luteal and postmenopausal phases in women with OA, and total serum E2 was lower in postmenopausal women with OA. Moreover, compared to healthy women, total serum 2-hydroxyestradiol was higher in postmenopausal women with OA and total serum 2-hydroxyestrone was lower in both the luteal and follicular phases in women with OA. In conclusion, our HPLC-ESI-MS/MS method allowed the measurement of multiple biochemical targets in a single assay, and, given its increased cost-effectiveness, simplicity, and speed relative to previous methods, this method is suitable for clinical studies.http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2015000200146&lng=en&tlng=enEstrogenEstrogen metabolitesMenopauseSerumOsteoathritis
spellingShingle W.L. Gao
L.S. Wu
J.H. Zi
B. Wu
Y.Z. Li
Y.C. Song
D.Z. Cai
Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
Brazilian Journal of Medical and Biological Research
Estrogen
Estrogen metabolites
Menopause
Serum
Osteoathritis
title Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
title_full Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
title_fullStr Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
title_full_unstemmed Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
title_short Measurement of serum estrogen and estrogen metabolites in pre- and postmenopausal women with osteoarthritis using high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry
title_sort measurement of serum estrogen and estrogen metabolites in pre and postmenopausal women with osteoarthritis using high performance liquid chromatography electrospray ionization tandem mass spectrometry
topic Estrogen
Estrogen metabolites
Menopause
Serum
Osteoathritis
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2015000200146&lng=en&tlng=en
work_keys_str_mv AT wlgao measurementofserumestrogenandestrogenmetabolitesinpreandpostmenopausalwomenwithosteoarthritisusinghighperformanceliquidchromatographyelectrosprayionizationtandemmassspectrometry
AT lswu measurementofserumestrogenandestrogenmetabolitesinpreandpostmenopausalwomenwithosteoarthritisusinghighperformanceliquidchromatographyelectrosprayionizationtandemmassspectrometry
AT jhzi measurementofserumestrogenandestrogenmetabolitesinpreandpostmenopausalwomenwithosteoarthritisusinghighperformanceliquidchromatographyelectrosprayionizationtandemmassspectrometry
AT bwu measurementofserumestrogenandestrogenmetabolitesinpreandpostmenopausalwomenwithosteoarthritisusinghighperformanceliquidchromatographyelectrosprayionizationtandemmassspectrometry
AT yzli measurementofserumestrogenandestrogenmetabolitesinpreandpostmenopausalwomenwithosteoarthritisusinghighperformanceliquidchromatographyelectrosprayionizationtandemmassspectrometry
AT ycsong measurementofserumestrogenandestrogenmetabolitesinpreandpostmenopausalwomenwithosteoarthritisusinghighperformanceliquidchromatographyelectrosprayionizationtandemmassspectrometry
AT dzcai measurementofserumestrogenandestrogenmetabolitesinpreandpostmenopausalwomenwithosteoarthritisusinghighperformanceliquidchromatographyelectrosprayionizationtandemmassspectrometry