Dry powder inhalers: Particle size and patient-satisfaction
Inhalational route is the cornerstone for drug delivery in asthma. Dry powder inhalers efficiently deliver drug particles to lungs depending on patients' breath actuation and without using propellants. Drug delivery in lungs is dependent primarily on particle size distribution of the formulatio...
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Jaypee Brothers Medical Publisher
2021-01-01
|
Series: | Indian Journal of Respiratory Care |
Subjects: | |
Online Access: | http://www.ijrc.in/article.asp?issn=2277-9019;year=2021;volume=10;issue=1;spage=14;epage=18;aulast=Jindal |
_version_ | 1797694390983983104 |
---|---|
author | S K Jindal K K Pandey P P Bose |
author_facet | S K Jindal K K Pandey P P Bose |
author_sort | S K Jindal |
collection | DOAJ |
description | Inhalational route is the cornerstone for drug delivery in asthma. Dry powder inhalers efficiently deliver drug particles to lungs depending on patients' breath actuation and without using propellants. Drug delivery in lungs is dependent primarily on particle size distribution of the formulation. Several studies have proved that drug particles 1–3 μm in size provide optimum efficacy with minimum adverse events. Particles >3 μm are deposited in the oropharynx and those <1 μm are exhaled. However, these fine particles might not be felt in the mouth due to which patients may feel that appropriate amount of drug was not dispensed. This perception may negatively influence patient satisfaction and confidence on the device. The patient education on the absence of mouthfeel is thus essential. Treating physicians should provide optimum patient counseling and education addressing the importance of particle size for desired clinical effects. |
first_indexed | 2024-03-12T02:57:12Z |
format | Article |
id | doaj.art-85650aed95f14125807759b143f1cb45 |
institution | Directory Open Access Journal |
issn | 2277-9019 2321-4899 |
language | English |
last_indexed | 2024-03-12T02:57:12Z |
publishDate | 2021-01-01 |
publisher | Jaypee Brothers Medical Publisher |
record_format | Article |
series | Indian Journal of Respiratory Care |
spelling | doaj.art-85650aed95f14125807759b143f1cb452023-09-03T15:12:33ZengJaypee Brothers Medical PublisherIndian Journal of Respiratory Care2277-90192321-48992021-01-01101141810.4103/ijrc.ijrc_57_19Dry powder inhalers: Particle size and patient-satisfactionS K JindalK K PandeyP P BoseInhalational route is the cornerstone for drug delivery in asthma. Dry powder inhalers efficiently deliver drug particles to lungs depending on patients' breath actuation and without using propellants. Drug delivery in lungs is dependent primarily on particle size distribution of the formulation. Several studies have proved that drug particles 1–3 μm in size provide optimum efficacy with minimum adverse events. Particles >3 μm are deposited in the oropharynx and those <1 μm are exhaled. However, these fine particles might not be felt in the mouth due to which patients may feel that appropriate amount of drug was not dispensed. This perception may negatively influence patient satisfaction and confidence on the device. The patient education on the absence of mouthfeel is thus essential. Treating physicians should provide optimum patient counseling and education addressing the importance of particle size for desired clinical effects.http://www.ijrc.in/article.asp?issn=2277-9019;year=2021;volume=10;issue=1;spage=14;epage=18;aulast=Jindalasthmachronic obstructive pulmonary diseasedry powder inhalerinhalational devicesmouthfeelparticle sizepatient education |
spellingShingle | S K Jindal K K Pandey P P Bose Dry powder inhalers: Particle size and patient-satisfaction Indian Journal of Respiratory Care asthma chronic obstructive pulmonary disease dry powder inhaler inhalational devices mouthfeel particle size patient education |
title | Dry powder inhalers: Particle size and patient-satisfaction |
title_full | Dry powder inhalers: Particle size and patient-satisfaction |
title_fullStr | Dry powder inhalers: Particle size and patient-satisfaction |
title_full_unstemmed | Dry powder inhalers: Particle size and patient-satisfaction |
title_short | Dry powder inhalers: Particle size and patient-satisfaction |
title_sort | dry powder inhalers particle size and patient satisfaction |
topic | asthma chronic obstructive pulmonary disease dry powder inhaler inhalational devices mouthfeel particle size patient education |
url | http://www.ijrc.in/article.asp?issn=2277-9019;year=2021;volume=10;issue=1;spage=14;epage=18;aulast=Jindal |
work_keys_str_mv | AT skjindal drypowderinhalersparticlesizeandpatientsatisfaction AT kkpandey drypowderinhalersparticlesizeandpatientsatisfaction AT ppbose drypowderinhalersparticlesizeandpatientsatisfaction |