Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated Grease

In this work different weight percent of copper and zinc powders of 20 ìm particlesize were blended carefully with grease , and the final weight of samples are 2 g . Thesamples were placed in containers were made from tephlon of 2.5 cm as a diameter . Thebottom window of container was fitted with 6...

Full description

Bibliographic Details
Main Author: Abdulhadi K. Judran AL-Ogaili
Format: Article
Language:English
Published: Unviversity of Technology- Iraq 2009-06-01
Series:Engineering and Technology Journal
Subjects:
Online Access:https://etj.uotechnology.edu.iq/article_36151_8248498e3634d5f1c4c67a37f78278a6.pdf
_version_ 1827358157618282496
author Abdulhadi K. Judran AL-Ogaili
author_facet Abdulhadi K. Judran AL-Ogaili
author_sort Abdulhadi K. Judran AL-Ogaili
collection DOAJ
description In this work different weight percent of copper and zinc powders of 20 ìm particlesize were blended carefully with grease , and the final weight of samples are 2 g . Thesamples were placed in containers were made from tephlon of 2.5 cm as a diameter . Thebottom window of container was fitted with 6 ìm mylar film . The samples weresubjected to X- ray fluorescence to measure the Cu Ká and Zn Ká lines intensities .Sensitivity (m) and Lower Limit Detection (LLD) were calculated and plotted againstthe weight fraction for all samples .
first_indexed 2024-03-08T06:06:42Z
format Article
id doaj.art-86f012e566e6468ebcf765c340292fc9
institution Directory Open Access Journal
issn 1681-6900
2412-0758
language English
last_indexed 2024-03-08T06:06:42Z
publishDate 2009-06-01
publisher Unviversity of Technology- Iraq
record_format Article
series Engineering and Technology Journal
spelling doaj.art-86f012e566e6468ebcf765c340292fc92024-02-04T17:49:34ZengUnviversity of Technology- IraqEngineering and Technology Journal1681-69002412-07582009-06-012781554155810.30684/etj.27.8.1136151Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated GreaseAbdulhadi K. Judran AL-OgailiIn this work different weight percent of copper and zinc powders of 20 ìm particlesize were blended carefully with grease , and the final weight of samples are 2 g . Thesamples were placed in containers were made from tephlon of 2.5 cm as a diameter . Thebottom window of container was fitted with 6 ìm mylar film . The samples weresubjected to X- ray fluorescence to measure the Cu Ká and Zn Ká lines intensities .Sensitivity (m) and Lower Limit Detection (LLD) were calculated and plotted againstthe weight fraction for all samples .https://etj.uotechnology.edu.iq/article_36151_8248498e3634d5f1c4c67a37f78278a6.pdfxrfsensitivitylower limit detectionsuspended particles
spellingShingle Abdulhadi K. Judran AL-Ogaili
Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated Grease
Engineering and Technology Journal
xrf
sensitivity
lower limit detection
suspended particles
title Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated Grease
title_full Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated Grease
title_fullStr Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated Grease
title_full_unstemmed Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated Grease
title_short Sensitivity and Lower Limit Detection Determined of XRF for Copper and Zinc Suspended in lubricated Grease
title_sort sensitivity and lower limit detection determined of xrf for copper and zinc suspended in lubricated grease
topic xrf
sensitivity
lower limit detection
suspended particles
url https://etj.uotechnology.edu.iq/article_36151_8248498e3634d5f1c4c67a37f78278a6.pdf
work_keys_str_mv AT abdulhadikjudranalogaili sensitivityandlowerlimitdetectiondeterminedofxrfforcopperandzincsuspendedinlubricatedgrease