Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch
In view of problems of poor tools and low work inefficiency existed in present failure detection equipment of mine-used low-voltage feeder switch, a novel model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch was designed. The test-bed takes PLC as controller, and can detect an...
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | zho |
Published: |
Editorial Department of Industry and Mine Automation
2015-03-01
|
Series: | Gong-kuang zidonghua |
Subjects: | |
Online Access: | http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2015.03.007 |
_version_ | 1797868781885718528 |
---|---|
author | HUANG Hesong REN Chengcheng GAO Xiang ZHANG Changhong CHEN Yujiang |
author_facet | HUANG Hesong REN Chengcheng GAO Xiang ZHANG Changhong CHEN Yujiang |
author_sort | HUANG Hesong |
collection | DOAJ |
description | In view of problems of poor tools and low work inefficiency existed in present failure detection equipment of mine-used low-voltage feeder switch, a novel model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch was designed. The test-bed takes PLC as controller, and can detect and monitor switch performances of over-voltage, under-voltage, over-load, short circuit, break, leakage and other abnormal conditions through operating buttons upon the test-bed with configuration technology. Meanwhile, the test-bed can detect performances of variety of models of mine-used low-voltage feeder switch, and can quickly judge switch failure, which reduces workload of maintenance personnel. |
first_indexed | 2024-04-10T00:01:20Z |
format | Article |
id | doaj.art-86f97575ffcd4b4d8613f0e51c1f5f11 |
institution | Directory Open Access Journal |
issn | 1671-251X |
language | zho |
last_indexed | 2024-04-10T00:01:20Z |
publishDate | 2015-03-01 |
publisher | Editorial Department of Industry and Mine Automation |
record_format | Article |
series | Gong-kuang zidonghua |
spelling | doaj.art-86f97575ffcd4b4d8613f0e51c1f5f112023-03-17T01:46:59ZzhoEditorial Department of Industry and Mine AutomationGong-kuang zidonghua1671-251X2015-03-01413283110.13272/j.issn.1671-251x.2015.03.007Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switchHUANG Hesong0REN Chengcheng1GAO Xiang2ZHANG Changhong3CHEN Yujiang4College of Electrical and Automation Engineering, Shandong University of Science and Technology, Qingdao 266590, ChinaCollege of Electrical and Automation Engineering, Shandong University of Science and Technology, Qingdao 266590, ChinaCollege of Electrical and Automation Engineering, Shandong University of Science and Technology, Qingdao 266590, ChinaCollege of Electrical and Automation Engineering, Shandong University of Science and Technology, Qingdao 266590, ChinaLuxi Coal Mine, Lineng Luxi Mining Group Co., Ltd., Jining 272000,ChinaIn view of problems of poor tools and low work inefficiency existed in present failure detection equipment of mine-used low-voltage feeder switch, a novel model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch was designed. The test-bed takes PLC as controller, and can detect and monitor switch performances of over-voltage, under-voltage, over-load, short circuit, break, leakage and other abnormal conditions through operating buttons upon the test-bed with configuration technology. Meanwhile, the test-bed can detect performances of variety of models of mine-used low-voltage feeder switch, and can quickly judge switch failure, which reduces workload of maintenance personnel.http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2015.03.007mine-used low-voltage feeder switchintegrated test-bedover-voltageunder-voltageover-loadshort circuitconfiguration technology |
spellingShingle | HUANG Hesong REN Chengcheng GAO Xiang ZHANG Changhong CHEN Yujiang Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch Gong-kuang zidonghua mine-used low-voltage feeder switch integrated test-bed over-voltage under-voltage over-load short circuit configuration technology |
title | Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch |
title_full | Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch |
title_fullStr | Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch |
title_full_unstemmed | Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch |
title_short | Design of model DFKG-2012 integrated test-bed for mine-used low-voltage feeder switch |
title_sort | design of model dfkg 2012 integrated test bed for mine used low voltage feeder switch |
topic | mine-used low-voltage feeder switch integrated test-bed over-voltage under-voltage over-load short circuit configuration technology |
url | http://www.gkzdh.cn/article/doi/10.13272/j.issn.1671-251x.2015.03.007 |
work_keys_str_mv | AT huanghesong designofmodeldfkg2012integratedtestbedformineusedlowvoltagefeederswitch AT renchengcheng designofmodeldfkg2012integratedtestbedformineusedlowvoltagefeederswitch AT gaoxiang designofmodeldfkg2012integratedtestbedformineusedlowvoltagefeederswitch AT zhangchanghong designofmodeldfkg2012integratedtestbedformineusedlowvoltagefeederswitch AT chenyujiang designofmodeldfkg2012integratedtestbedformineusedlowvoltagefeederswitch |