Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation

Introduction: Electrocardiographic Imaging (ECGI) allows computing the electrical activity in the heart non-invasively using geometrical information of the patient and multiple body surface signals. In the present study we investigate the influence of the number of nodes of geometrical meshes and re...

Full description

Bibliographic Details
Main Authors: Rubén Molero, Ana González-Ascaso, Ismael Hernández-Romero, David Lundback-Mompó, Andreu M. Climent, María S. Guillem
Format: Article
Language:English
Published: Frontiers Media S.A. 2022-08-01
Series:Frontiers in Physiology
Subjects:
Online Access:https://www.frontiersin.org/articles/10.3389/fphys.2022.908364/full
_version_ 1811282700910198784
author Rubén Molero
Ana González-Ascaso
Ismael Hernández-Romero
David Lundback-Mompó
Andreu M. Climent
María S. Guillem
author_facet Rubén Molero
Ana González-Ascaso
Ismael Hernández-Romero
David Lundback-Mompó
Andreu M. Climent
María S. Guillem
author_sort Rubén Molero
collection DOAJ
description Introduction: Electrocardiographic Imaging (ECGI) allows computing the electrical activity in the heart non-invasively using geometrical information of the patient and multiple body surface signals. In the present study we investigate the influence of the number of nodes of geometrical meshes and recording ECG electrodes distribution to compute ECGI during atrial fibrillation (AF).Methods: Torso meshes from 100 to 2000 nodes heterogeneously and homogeneously distributed were compared. Signals from nine AF realistic mathematical simulations were used for computing the ECGI. Results for each torso mesh were compared with the ECGI computed with a 4,000 nodes reference torso. In addition, real AF recordings from 25 AF patients were used to compute ECGI in torso meshes from 100 to 1,000 nodes. Results were compared with a reference torso of 2000 nodes. Torsos were remeshed either by reducing the number of nodes while maximizing the overall shape preservation and then assigning the location of the electrodes as the closest node in the new mesh or by forcing the remesher to place a node at each electrode location. Correlation coefficients, relative difference measurements and relative difference of dominant frequencies were computed to evaluate the impact on signal morphology of each torso mesh.Results: For remeshed torsos where electrodes match with a geometrical node in the mesh, all mesh densities presented similar results. On the other hand, in torsos with electrodes assigned to closest nodes in remeshed geometries performance metrics were dependent on mesh densities, with correlation coefficients ranging from 0.53 ± 0.06 to 0.92 ± 0.04 in simulations or from 0.42 ± 0.38 to 0.89 ± 0.2 in patients. Dominant frequency relative errors showed the same trend with values from 1.14 ± 0.26 to 0.55 ± 0.21 Hz in simulations and from 0.91 ± 0.56 to 0.45 ± 0.41 Hz in patients.Conclusion: The effect of mesh density in ECGI is minimal when the location of the electrode is preserved as a node in the mesh. Torso meshes constructed without imposing electrodes to constitute nodes in the torso geometry should contain at least 400 nodes homogeneously distributed so that a distance between nodes is below 4 cm.
first_indexed 2024-04-13T01:57:18Z
format Article
id doaj.art-873357e3cd6243bd88f116323f683454
institution Directory Open Access Journal
issn 1664-042X
language English
last_indexed 2024-04-13T01:57:18Z
publishDate 2022-08-01
publisher Frontiers Media S.A.
record_format Article
series Frontiers in Physiology
spelling doaj.art-873357e3cd6243bd88f116323f6834542022-12-22T03:07:44ZengFrontiers Media S.A.Frontiers in Physiology1664-042X2022-08-011310.3389/fphys.2022.908364908364Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillationRubén Molero0Ana González-Ascaso1Ismael Hernández-Romero2David Lundback-Mompó3Andreu M. Climent4María S. Guillem5ITACA Institute, Universitat Politècnica de València, València, SpainITACA Institute, Universitat Politècnica de València, València, SpainITACA Institute, Universitat Politècnica de València, València, SpainCorify Care SL, Madrid, SpainITACA Institute, Universitat Politècnica de València, València, SpainITACA Institute, Universitat Politècnica de València, València, SpainIntroduction: Electrocardiographic Imaging (ECGI) allows computing the electrical activity in the heart non-invasively using geometrical information of the patient and multiple body surface signals. In the present study we investigate the influence of the number of nodes of geometrical meshes and recording ECG electrodes distribution to compute ECGI during atrial fibrillation (AF).Methods: Torso meshes from 100 to 2000 nodes heterogeneously and homogeneously distributed were compared. Signals from nine AF realistic mathematical simulations were used for computing the ECGI. Results for each torso mesh were compared with the ECGI computed with a 4,000 nodes reference torso. In addition, real AF recordings from 25 AF patients were used to compute ECGI in torso meshes from 100 to 1,000 nodes. Results were compared with a reference torso of 2000 nodes. Torsos were remeshed either by reducing the number of nodes while maximizing the overall shape preservation and then assigning the location of the electrodes as the closest node in the new mesh or by forcing the remesher to place a node at each electrode location. Correlation coefficients, relative difference measurements and relative difference of dominant frequencies were computed to evaluate the impact on signal morphology of each torso mesh.Results: For remeshed torsos where electrodes match with a geometrical node in the mesh, all mesh densities presented similar results. On the other hand, in torsos with electrodes assigned to closest nodes in remeshed geometries performance metrics were dependent on mesh densities, with correlation coefficients ranging from 0.53 ± 0.06 to 0.92 ± 0.04 in simulations or from 0.42 ± 0.38 to 0.89 ± 0.2 in patients. Dominant frequency relative errors showed the same trend with values from 1.14 ± 0.26 to 0.55 ± 0.21 Hz in simulations and from 0.91 ± 0.56 to 0.45 ± 0.41 Hz in patients.Conclusion: The effect of mesh density in ECGI is minimal when the location of the electrode is preserved as a node in the mesh. Torso meshes constructed without imposing electrodes to constitute nodes in the torso geometry should contain at least 400 nodes homogeneously distributed so that a distance between nodes is below 4 cm.https://www.frontiersin.org/articles/10.3389/fphys.2022.908364/fullelectrocardiographic imaginggeometrytorsoatrial fibrillationmesh density
spellingShingle Rubén Molero
Ana González-Ascaso
Ismael Hernández-Romero
David Lundback-Mompó
Andreu M. Climent
María S. Guillem
Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation
Frontiers in Physiology
electrocardiographic imaging
geometry
torso
atrial fibrillation
mesh density
title Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation
title_full Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation
title_fullStr Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation
title_full_unstemmed Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation
title_short Effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation
title_sort effects of torso mesh density and electrode distribution on the accuracy of electrocardiographic imaging during atrial fibrillation
topic electrocardiographic imaging
geometry
torso
atrial fibrillation
mesh density
url https://www.frontiersin.org/articles/10.3389/fphys.2022.908364/full
work_keys_str_mv AT rubenmolero effectsoftorsomeshdensityandelectrodedistributionontheaccuracyofelectrocardiographicimagingduringatrialfibrillation
AT anagonzalezascaso effectsoftorsomeshdensityandelectrodedistributionontheaccuracyofelectrocardiographicimagingduringatrialfibrillation
AT ismaelhernandezromero effectsoftorsomeshdensityandelectrodedistributionontheaccuracyofelectrocardiographicimagingduringatrialfibrillation
AT davidlundbackmompo effectsoftorsomeshdensityandelectrodedistributionontheaccuracyofelectrocardiographicimagingduringatrialfibrillation
AT andreumcliment effectsoftorsomeshdensityandelectrodedistributionontheaccuracyofelectrocardiographicimagingduringatrialfibrillation
AT mariasguillem effectsoftorsomeshdensityandelectrodedistributionontheaccuracyofelectrocardiographicimagingduringatrialfibrillation