Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motors

This publication considers the issues of development of the software program for designing of 0,4 kV power supply systems with motor-actuated load under voltage unsymmetry conditions (using the example of the Trans-Baikal Territory). Voltage unsymmetry is practically constant phenomenon in the elect...

Full description

Bibliographic Details
Main Authors: Romanova Victoria, Khromov Sergey, Suvorov Ivan, Balbekina Kristina
Format: Article
Language:English
Published: EDP Sciences 2017-01-01
Series:E3S Web of Conferences
Online Access:https://doi.org/10.1051/e3sconf/20172504002
_version_ 1818447143125385216
author Romanova Victoria
Khromov Sergey
Suvorov Ivan
Balbekina Kristina
author_facet Romanova Victoria
Khromov Sergey
Suvorov Ivan
Balbekina Kristina
author_sort Romanova Victoria
collection DOAJ
description This publication considers the issues of development of the software program for designing of 0,4 kV power supply systems with motor-actuated load under voltage unsymmetry conditions (using the example of the Trans-Baikal Territory). Voltage unsymmetry is practically constant phenomenon in the electric power networks of different voltage types. Voltage unsymmetry effects significantly the electric power consumers, including the supply mains itself. It has especially negative impact on the electrical equipment operation process and its lifetime. The urgency of the problem is confirmed by multiple research on the same topic and by significant number of damages suffered by the electric power consumers staying in service (especially in the Trans-Baikal Territory and in the Far-East regions). Voltage unsymmetry causes economic loss and reduction of the electromagnetic interference value by the voltage unsymmetry coefficient in negative-phase sequence (K2U) gives inevitable economic effect accordingly. However, the payback period for the activities aimed at reduction of electromagnetic interference, will vary from some months to several years. The more accurate value of the payback period may be obtained using the developed software program. The developed software design program is implemented by means of the programming language C# in Microsoft Visual Studio environment, using the built-in cross-platform database SQLite. The software program shall allow making quick and accurate calculation of the power losses, to determine the economic feasibility of provision special measures for removal of the voltage unsymmetry, for determination of optimal application and location of the balancing devices. The software implementation in power systems loaded with electric motors will improve reliability and efficiency of asynchronous motors. The software is of interest for developers of projects on power supply systems for regions with non-linear loads.
first_indexed 2024-12-14T19:58:56Z
format Article
id doaj.art-874b9ea36031443c91dff4154f4388b0
institution Directory Open Access Journal
issn 2267-1242
language English
last_indexed 2024-12-14T19:58:56Z
publishDate 2017-01-01
publisher EDP Sciences
record_format Article
series E3S Web of Conferences
spelling doaj.art-874b9ea36031443c91dff4154f4388b02022-12-21T22:49:12ZengEDP SciencesE3S Web of Conferences2267-12422017-01-01250400210.1051/e3sconf/20172504002e3sconf_rses2017_04002Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motorsRomanova VictoriaKhromov SergeySuvorov IvanBalbekina KristinaThis publication considers the issues of development of the software program for designing of 0,4 kV power supply systems with motor-actuated load under voltage unsymmetry conditions (using the example of the Trans-Baikal Territory). Voltage unsymmetry is practically constant phenomenon in the electric power networks of different voltage types. Voltage unsymmetry effects significantly the electric power consumers, including the supply mains itself. It has especially negative impact on the electrical equipment operation process and its lifetime. The urgency of the problem is confirmed by multiple research on the same topic and by significant number of damages suffered by the electric power consumers staying in service (especially in the Trans-Baikal Territory and in the Far-East regions). Voltage unsymmetry causes economic loss and reduction of the electromagnetic interference value by the voltage unsymmetry coefficient in negative-phase sequence (K2U) gives inevitable economic effect accordingly. However, the payback period for the activities aimed at reduction of electromagnetic interference, will vary from some months to several years. The more accurate value of the payback period may be obtained using the developed software program. The developed software design program is implemented by means of the programming language C# in Microsoft Visual Studio environment, using the built-in cross-platform database SQLite. The software program shall allow making quick and accurate calculation of the power losses, to determine the economic feasibility of provision special measures for removal of the voltage unsymmetry, for determination of optimal application and location of the balancing devices. The software implementation in power systems loaded with electric motors will improve reliability and efficiency of asynchronous motors. The software is of interest for developers of projects on power supply systems for regions with non-linear loads.https://doi.org/10.1051/e3sconf/20172504002
spellingShingle Romanova Victoria
Khromov Sergey
Suvorov Ivan
Balbekina Kristina
Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motors
E3S Web of Conferences
title Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motors
title_full Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motors
title_fullStr Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motors
title_full_unstemmed Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motors
title_short Software for optimal selection of places for installation of balancing devices in 0,4 kV electric power systems loaded with electric motors
title_sort software for optimal selection of places for installation of balancing devices in 0 4 kv electric power systems loaded with electric motors
url https://doi.org/10.1051/e3sconf/20172504002
work_keys_str_mv AT romanovavictoria softwareforoptimalselectionofplacesforinstallationofbalancingdevicesin04kvelectricpowersystemsloadedwithelectricmotors
AT khromovsergey softwareforoptimalselectionofplacesforinstallationofbalancingdevicesin04kvelectricpowersystemsloadedwithelectricmotors
AT suvorovivan softwareforoptimalselectionofplacesforinstallationofbalancingdevicesin04kvelectricpowersystemsloadedwithelectricmotors
AT balbekinakristina softwareforoptimalselectionofplacesforinstallationofbalancingdevicesin04kvelectricpowersystemsloadedwithelectricmotors