Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station

With the rapid development of pumped storage, the vibration problems caused by the operation of power stations have become increasingly prominent. In this paper, a large-scale pumped-storage power station is taken as the research object, and a three-dimensional refined finite element model of the un...

Full description

Bibliographic Details
Main Authors: Lijuan Zhang, Yaohua Guo, Haijun Wang, Xuliang Yang, Jijian Lian
Format: Article
Language:English
Published: MDPI AG 2022-12-01
Series:Energies
Subjects:
Online Access:https://www.mdpi.com/1996-1073/15/24/9637
_version_ 1827639998708449280
author Lijuan Zhang
Yaohua Guo
Haijun Wang
Xuliang Yang
Jijian Lian
author_facet Lijuan Zhang
Yaohua Guo
Haijun Wang
Xuliang Yang
Jijian Lian
author_sort Lijuan Zhang
collection DOAJ
description With the rapid development of pumped storage, the vibration problems caused by the operation of power stations have become increasingly prominent. In this paper, a large-scale pumped-storage power station is taken as the research object, and a three-dimensional refined finite element model of the underground powerhouse including the surrounding rock mass is established. Based on the analysis of the vibration source of the powerhouse and the water diversion pipeline, the modal and dynamic response analysis of the underground powerhouse of the hydropower station is carried out, and the distribution law of the larger vibration displacement position is revealed. The calculation results show that under the premise that the vibration source is selected reasonably and the numerical model is accurate, the main frequency of the underground powerhouse structure can be obtained more accurately. After optimizing the design of the underground powerhouse based on the calculation results, the resonance problem of the underground powerhouse of the hydropower station can be avoided. The dynamic elastic modulus of the rock mass around the underground powerhouse has little influence on the mode shape of the powerhouse, but has a great influence on its fundamental frequency. When the dynamic elastic modulus of the rock mass increases by 50%, the fundamental frequency of the plant increases by about 29%. At the same time, the mode shape of each order of the underground powerhouse structure does not change much, mainly manifested as the vibration of the beam system structure, which is mainly caused by the stiffness of the beam system components being much smaller than the structural stiffness of the windshield, machine pier, and mass concrete around the volute. The research results can provide references for the design of underground powerhouses of large-scale pumped-storage power stations and the analysis of vibration problems.
first_indexed 2024-03-09T16:51:50Z
format Article
id doaj.art-877c87d21fbf483397f6fd2c5ed5abb0
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-03-09T16:51:50Z
publishDate 2022-12-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-877c87d21fbf483397f6fd2c5ed5abb02023-11-24T14:40:35ZengMDPI AGEnergies1996-10732022-12-011524963710.3390/en15249637Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power StationLijuan Zhang0Yaohua Guo1Haijun Wang2Xuliang Yang3Jijian Lian4School of Civil and Transportation Engineering, Qinghai Minzu University, Qinghai 810007, ChinaState Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University, Tianjin 300072, ChinaState Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University, Tianjin 300072, ChinaSchool of Civil and Transportation Engineering, Qinghai Minzu University, Qinghai 810007, ChinaState Key Laboratory of Hydraulic Engineering Simulation and Safety, Tianjin University, Tianjin 300072, ChinaWith the rapid development of pumped storage, the vibration problems caused by the operation of power stations have become increasingly prominent. In this paper, a large-scale pumped-storage power station is taken as the research object, and a three-dimensional refined finite element model of the underground powerhouse including the surrounding rock mass is established. Based on the analysis of the vibration source of the powerhouse and the water diversion pipeline, the modal and dynamic response analysis of the underground powerhouse of the hydropower station is carried out, and the distribution law of the larger vibration displacement position is revealed. The calculation results show that under the premise that the vibration source is selected reasonably and the numerical model is accurate, the main frequency of the underground powerhouse structure can be obtained more accurately. After optimizing the design of the underground powerhouse based on the calculation results, the resonance problem of the underground powerhouse of the hydropower station can be avoided. The dynamic elastic modulus of the rock mass around the underground powerhouse has little influence on the mode shape of the powerhouse, but has a great influence on its fundamental frequency. When the dynamic elastic modulus of the rock mass increases by 50%, the fundamental frequency of the plant increases by about 29%. At the same time, the mode shape of each order of the underground powerhouse structure does not change much, mainly manifested as the vibration of the beam system structure, which is mainly caused by the stiffness of the beam system components being much smaller than the structural stiffness of the windshield, machine pier, and mass concrete around the volute. The research results can provide references for the design of underground powerhouses of large-scale pumped-storage power stations and the analysis of vibration problems.https://www.mdpi.com/1996-1073/15/24/9637pumped storage power stationunderground powerhousevibrationmodal analysissteady state response
spellingShingle Lijuan Zhang
Yaohua Guo
Haijun Wang
Xuliang Yang
Jijian Lian
Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station
Energies
pumped storage power station
underground powerhouse
vibration
modal analysis
steady state response
title Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station
title_full Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station
title_fullStr Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station
title_full_unstemmed Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station
title_short Research on Vibration Characteristics of an Underground Powerhouse of Large Pumped-Storage Power Station
title_sort research on vibration characteristics of an underground powerhouse of large pumped storage power station
topic pumped storage power station
underground powerhouse
vibration
modal analysis
steady state response
url https://www.mdpi.com/1996-1073/15/24/9637
work_keys_str_mv AT lijuanzhang researchonvibrationcharacteristicsofanundergroundpowerhouseoflargepumpedstoragepowerstation
AT yaohuaguo researchonvibrationcharacteristicsofanundergroundpowerhouseoflargepumpedstoragepowerstation
AT haijunwang researchonvibrationcharacteristicsofanundergroundpowerhouseoflargepumpedstoragepowerstation
AT xuliangyang researchonvibrationcharacteristicsofanundergroundpowerhouseoflargepumpedstoragepowerstation
AT jijianlian researchonvibrationcharacteristicsofanundergroundpowerhouseoflargepumpedstoragepowerstation