Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay

As an important part of the smart grid, a wide-area measurement system (WAMS) provides the key technical support for power system monitoring, protection and control. But 20 uncertainties in system parameters and signal transmission time delay could worsen the damping effect and deteriorate the syste...

Full description

Bibliographic Details
Main Authors: Deyou Yang, Guowei Cai, Cheng Liu
Format: Article
Language:English
Published: MDPI AG 2013-09-01
Series:Energies
Subjects:
Online Access:http://www.mdpi.com/1996-1073/6/9/4841
_version_ 1817995133423976448
author Deyou Yang
Guowei Cai
Cheng Liu
author_facet Deyou Yang
Guowei Cai
Cheng Liu
author_sort Deyou Yang
collection DOAJ
description As an important part of the smart grid, a wide-area measurement system (WAMS) provides the key technical support for power system monitoring, protection and control. But 20 uncertainties in system parameters and signal transmission time delay could worsen the damping effect and deteriorate the system stability. In the presented study, the subspace system identification technique (SIT) is used to firstly derive a low-order linear model of a power system from the measurements. Then, a novel adaptive wide-area damping control scheme for online tuning of the wide-area damping controller (WADC) parameters using the residue method is proposed. In order to eliminate the effects of the time delay to the signal transmission, a simple and practical time delay compensation algorithm is proposed to compensate the time delay in each wide-area control signal. Detailed examples, inspired by the IEEE test system under various disturbance scenarios, have been used to verify the effectiveness of the proposed adaptive wide-area damping control scheme.
first_indexed 2024-04-14T02:02:33Z
format Article
id doaj.art-878fca90063e448f852a13cb18732b08
institution Directory Open Access Journal
issn 1996-1073
language English
last_indexed 2024-04-14T02:02:33Z
publishDate 2013-09-01
publisher MDPI AG
record_format Article
series Energies
spelling doaj.art-878fca90063e448f852a13cb18732b082022-12-22T02:18:48ZengMDPI AGEnergies1996-10732013-09-01694841485810.3390/en6094841Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time DelayDeyou YangGuowei CaiCheng LiuAs an important part of the smart grid, a wide-area measurement system (WAMS) provides the key technical support for power system monitoring, protection and control. But 20 uncertainties in system parameters and signal transmission time delay could worsen the damping effect and deteriorate the system stability. In the presented study, the subspace system identification technique (SIT) is used to firstly derive a low-order linear model of a power system from the measurements. Then, a novel adaptive wide-area damping control scheme for online tuning of the wide-area damping controller (WADC) parameters using the residue method is proposed. In order to eliminate the effects of the time delay to the signal transmission, a simple and practical time delay compensation algorithm is proposed to compensate the time delay in each wide-area control signal. Detailed examples, inspired by the IEEE test system under various disturbance scenarios, have been used to verify the effectiveness of the proposed adaptive wide-area damping control scheme.http://www.mdpi.com/1996-1073/6/9/4841smart gridinter-area oscillationsubspace identification technique (SIT)wide-area measurement system (WAMS)time delaywide-area damping controller (WADC)
spellingShingle Deyou Yang
Guowei Cai
Cheng Liu
Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay
Energies
smart grid
inter-area oscillation
subspace identification technique (SIT)
wide-area measurement system (WAMS)
time delay
wide-area damping controller (WADC)
title Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay
title_full Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay
title_fullStr Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay
title_full_unstemmed Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay
title_short Adaptive Wide-Area Damping Control Scheme for Smart Grids with Consideration of Signal Time Delay
title_sort adaptive wide area damping control scheme for smart grids with consideration of signal time delay
topic smart grid
inter-area oscillation
subspace identification technique (SIT)
wide-area measurement system (WAMS)
time delay
wide-area damping controller (WADC)
url http://www.mdpi.com/1996-1073/6/9/4841
work_keys_str_mv AT deyouyang adaptivewideareadampingcontrolschemeforsmartgridswithconsiderationofsignaltimedelay
AT guoweicai adaptivewideareadampingcontrolschemeforsmartgridswithconsiderationofsignaltimedelay
AT chengliu adaptivewideareadampingcontrolschemeforsmartgridswithconsiderationofsignaltimedelay