Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray Imaging

Abstract High‐resolution X‐ray imaging is increasingly required for medical diagnosis and large‐area detection. However, the issues of scattering and optical crosstalk are limiting the spatial resolution of the indirect X‐ray imaging. In this study, a feasible and efficient strategy is proposed to i...

Full description

Bibliographic Details
Main Authors: Weiqing Chen, Ting Wang, Tianchi Wang, Jing Yu, Shuyi Yao, Wei Feng, Qingyuan Wang, Ling Huang, Xuhui Xu, Xue Yu
Format: Article
Language:English
Published: Wiley 2023-12-01
Series:Advanced Science
Subjects:
Online Access:https://doi.org/10.1002/advs.202304957
_version_ 1797401827293003776
author Weiqing Chen
Ting Wang
Tianchi Wang
Jing Yu
Shuyi Yao
Wei Feng
Qingyuan Wang
Ling Huang
Xuhui Xu
Xue Yu
author_facet Weiqing Chen
Ting Wang
Tianchi Wang
Jing Yu
Shuyi Yao
Wei Feng
Qingyuan Wang
Ling Huang
Xuhui Xu
Xue Yu
author_sort Weiqing Chen
collection DOAJ
description Abstract High‐resolution X‐ray imaging is increasingly required for medical diagnosis and large‐area detection. However, the issues of scattering and optical crosstalk are limiting the spatial resolution of the indirect X‐ray imaging. In this study, a feasible and efficient strategy is proposed to in situ synthesize flexible Cs3Cu2I5:2%In+@paper as a superior scintillator film, which can be scaled up to an ultra‐large area of 4800 cm2. The as‐obtained Cs3Cu2I5:2%In+@paper performs a fascinating photoluminescence quantum efficiency up to 88.14%, a steady state light yield of 70169 photons/MeV, and spatial resolution of 15 lp mm−1. Moreover, the suppressed physical scattering and optical crosstalk of the corresponding film are demonstrated. Accordingly, this work explores a feasible fabrication of customizable scintillation films with large area for high‐resolution X‐ray detection.
first_indexed 2024-03-09T02:15:57Z
format Article
id doaj.art-8807bfddd8404de2840825d459b445cc
institution Directory Open Access Journal
issn 2198-3844
language English
last_indexed 2024-03-09T02:15:57Z
publishDate 2023-12-01
publisher Wiley
record_format Article
series Advanced Science
spelling doaj.art-8807bfddd8404de2840825d459b445cc2023-12-07T04:08:36ZengWileyAdvanced Science2198-38442023-12-011034n/an/a10.1002/advs.202304957Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray ImagingWeiqing Chen0Ting Wang1Tianchi Wang2Jing Yu3Shuyi Yao4Wei Feng5Qingyuan Wang6Ling Huang7Xuhui Xu8Xue Yu9School of Mechanical Engineering Institute for Advanced Materials Chengdu University Chengdu 610106 P. R. ChinaCollege of Materials and Chemistry & Chemical Engineering Chengdu University of Technology Chengdu Sichuan 610059 P. R. ChinaFaculty of Materials Science and Engineering Key Laboratory of Advanced Materials of Yunnan Province Kunming University of Science and Technology Kunming Yunnan 650093 P. R. ChinaFaculty of Materials Science and Engineering Key Laboratory of Advanced Materials of Yunnan Province Kunming University of Science and Technology Kunming Yunnan 650093 P. R. ChinaFaculty of Materials Science and Engineering Key Laboratory of Advanced Materials of Yunnan Province Kunming University of Science and Technology Kunming Yunnan 650093 P. R. ChinaSchool of Mechanical Engineering Institute for Advanced Materials Chengdu University Chengdu 610106 P. R. ChinaSchool of Mechanical Engineering Institute for Advanced Materials Chengdu University Chengdu 610106 P. R. ChinaState Key Laboratory of Chemistry and Utilization of Carbon Based Energy Resources College of Chemistry Xinjiang University Urumqi 830046 P. R. ChinaFaculty of Materials Science and Engineering Key Laboratory of Advanced Materials of Yunnan Province Kunming University of Science and Technology Kunming Yunnan 650093 P. R. ChinaSchool of Mechanical Engineering Institute for Advanced Materials Chengdu University Chengdu 610106 P. R. ChinaAbstract High‐resolution X‐ray imaging is increasingly required for medical diagnosis and large‐area detection. However, the issues of scattering and optical crosstalk are limiting the spatial resolution of the indirect X‐ray imaging. In this study, a feasible and efficient strategy is proposed to in situ synthesize flexible Cs3Cu2I5:2%In+@paper as a superior scintillator film, which can be scaled up to an ultra‐large area of 4800 cm2. The as‐obtained Cs3Cu2I5:2%In+@paper performs a fascinating photoluminescence quantum efficiency up to 88.14%, a steady state light yield of 70169 photons/MeV, and spatial resolution of 15 lp mm−1. Moreover, the suppressed physical scattering and optical crosstalk of the corresponding film are demonstrated. Accordingly, this work explores a feasible fabrication of customizable scintillation films with large area for high‐resolution X‐ray detection.https://doi.org/10.1002/advs.202304957customizable scintillatorlarge‐areaoptical crosstalkperovskite@paperphysical scattering
spellingShingle Weiqing Chen
Ting Wang
Tianchi Wang
Jing Yu
Shuyi Yao
Wei Feng
Qingyuan Wang
Ling Huang
Xuhui Xu
Xue Yu
Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray Imaging
Advanced Science
customizable scintillator
large‐area
optical crosstalk
perovskite@paper
physical scattering
title Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray Imaging
title_full Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray Imaging
title_fullStr Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray Imaging
title_full_unstemmed Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray Imaging
title_short Customizable Scintillator of Cs3Cu2I5:2% In+@Paper for Large‐Area X‐Ray Imaging
title_sort customizable scintillator of cs3cu2i5 2 in paper for large area x ray imaging
topic customizable scintillator
large‐area
optical crosstalk
perovskite@paper
physical scattering
url https://doi.org/10.1002/advs.202304957
work_keys_str_mv AT weiqingchen customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT tingwang customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT tianchiwang customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT jingyu customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT shuyiyao customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT weifeng customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT qingyuanwang customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT linghuang customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT xuhuixu customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging
AT xueyu customizablescintillatorofcs3cu2i52inpaperforlargeareaxrayimaging