Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics

ObjectiveTo establish bovine corneal opacity and permeability (BCOP) test, and determine its predictive ability for the eye irritation evaluation of cosmetics.MethodsA total of ten reference chemicals were selected to establish the BCOP test. Then eye irritation of 16 routinely collected cosmetics i...

Full description

Bibliographic Details
Main Authors: HUO Qian, SHA Yijie, XIAO Ping, HONG Xinyu, WANG Letian, ZHENG Weidong, WEI Qi, DONG Cheng, TAO Gonghua
Format: Article
Language:zho
Published: Shanghai Preventive Medicine Association 2022-02-01
Series:Shanghai yufang yixue
Subjects:
Online Access:http://www.sjpm.org.cn/article/doi/10.19428/j.cnki.sjpm.2022.21430
_version_ 1827246028386992128
author HUO Qian
SHA Yijie
XIAO Ping
HONG Xinyu
WANG Letian
ZHENG Weidong
WEI Qi
DONG Cheng
TAO Gonghua
author_facet HUO Qian
SHA Yijie
XIAO Ping
HONG Xinyu
WANG Letian
ZHENG Weidong
WEI Qi
DONG Cheng
TAO Gonghua
author_sort HUO Qian
collection DOAJ
description ObjectiveTo establish bovine corneal opacity and permeability (BCOP) test, and determine its predictive ability for the eye irritation evaluation of cosmetics.MethodsA total of ten reference chemicals were selected to establish the BCOP test. Then eye irritation of 16 routinely collected cosmetics in our laboratory was predicted. In vitro scores were calculated by the change in the opacity and sodium fluorescein permeability after exposure to the testing cosmetics, and subsequently compared with the historical data by Draize test.ResultsReference chemicals with known irritation classification were correctly classified by the BCOP test, which was consistent with the classification of UN globally harmonized system of classification and labeling of chemicals. Moreover, the specificity of the BCOP test for the classification of non-irritating cosmetics samples was 80.0% (8/10), and the sensitivity for weak to mild irritating cosmetics samples was 83.3% (5/6). The BCOP test demonstrated an overall classification consistency of 81.3% (13/16) with in vivo test.ConclusionBCOP test may be independently used to identify chemicals with potential eye irritation and serious eye damage, suggesting it is significant for in vitro integrated test strategy for predicting eye irritation due to cosmetics.
first_indexed 2024-04-10T19:13:34Z
format Article
id doaj.art-88174028306f4c02a96a024ddd94c44d
institution Directory Open Access Journal
issn 1004-9231
language zho
last_indexed 2025-03-21T22:53:27Z
publishDate 2022-02-01
publisher Shanghai Preventive Medicine Association
record_format Article
series Shanghai yufang yixue
spelling doaj.art-88174028306f4c02a96a024ddd94c44d2024-05-23T11:39:47ZzhoShanghai Preventive Medicine AssociationShanghai yufang yixue1004-92312022-02-0134218318610.19428/j.cnki.sjpm.2022.214301004-9231(2022)02-0183-04Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmeticsHUO Qian0SHA Yijie1XIAO Ping2HONG Xinyu3WANG Letian4ZHENG Weidong5WEI Qi6DONG Cheng7TAO Gonghua8Division of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaDivision of Chemical Toxicity & Safety Assessment, Shanghai Municipal Center for Disease Control & Prevention, State Environmental Protection Key Laboratory of Environmental Health Impact Assessment of Emerging Contaminants, NMPA Key Laboratory for Monitoring and Evaluation of Cosmetics, Shanghai 200336, ChinaObjectiveTo establish bovine corneal opacity and permeability (BCOP) test, and determine its predictive ability for the eye irritation evaluation of cosmetics.MethodsA total of ten reference chemicals were selected to establish the BCOP test. Then eye irritation of 16 routinely collected cosmetics in our laboratory was predicted. In vitro scores were calculated by the change in the opacity and sodium fluorescein permeability after exposure to the testing cosmetics, and subsequently compared with the historical data by Draize test.ResultsReference chemicals with known irritation classification were correctly classified by the BCOP test, which was consistent with the classification of UN globally harmonized system of classification and labeling of chemicals. Moreover, the specificity of the BCOP test for the classification of non-irritating cosmetics samples was 80.0% (8/10), and the sensitivity for weak to mild irritating cosmetics samples was 83.3% (5/6). The BCOP test demonstrated an overall classification consistency of 81.3% (13/16) with in vivo test.ConclusionBCOP test may be independently used to identify chemicals with potential eye irritation and serious eye damage, suggesting it is significant for in vitro integrated test strategy for predicting eye irritation due to cosmetics.http://www.sjpm.org.cn/article/doi/10.19428/j.cnki.sjpm.2022.21430bovine corneal opacity and permeability test (bcop)eye irritationcosmetics
spellingShingle HUO Qian
SHA Yijie
XIAO Ping
HONG Xinyu
WANG Letian
ZHENG Weidong
WEI Qi
DONG Cheng
TAO Gonghua
Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics
Shanghai yufang yixue
bovine corneal opacity and permeability test (bcop)
eye irritation
cosmetics
title Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics
title_full Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics
title_fullStr Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics
title_full_unstemmed Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics
title_short Application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics
title_sort application of bovine corneal opacity and permeability test in the eye irritation evaluation of cosmetics
topic bovine corneal opacity and permeability test (bcop)
eye irritation
cosmetics
url http://www.sjpm.org.cn/article/doi/10.19428/j.cnki.sjpm.2022.21430
work_keys_str_mv AT huoqian applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT shayijie applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT xiaoping applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT hongxinyu applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT wangletian applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT zhengweidong applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT weiqi applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT dongcheng applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics
AT taogonghua applicationofbovinecornealopacityandpermeabilitytestintheeyeirritationevaluationofcosmetics