Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger

The main objective of this numerical study is to investigate the ways to reduce the pressure drop and consequently increase thermal performance enhancement factor (TEF) of a heat exchanger equipped with twisted tapes. For this purpose, axial perforated twisted tapes (PTTs) with various hole diameter...

Full description

Bibliographic Details
Main Authors: Nemat Mashoofi, Saman Pourahmad, S.M. Pesteei
Format: Article
Language:English
Published: Elsevier 2017-09-01
Series:Case Studies in Thermal Engineering
Subjects:
Online Access:http://www.sciencedirect.com/science/article/pii/S2214157X17300758
_version_ 1819231662018396160
author Nemat Mashoofi
Saman Pourahmad
S.M. Pesteei
author_facet Nemat Mashoofi
Saman Pourahmad
S.M. Pesteei
author_sort Nemat Mashoofi
collection DOAJ
description The main objective of this numerical study is to investigate the ways to reduce the pressure drop and consequently increase thermal performance enhancement factor (TEF) of a heat exchanger equipped with twisted tapes. For this purpose, axial perforated twisted tapes (PTTs) with various hole diameters are used instead of simple twisted tapes (STTs). Moreover, the variations of the effectiveness with number of transfer units (NTU) for different heat capacity ratios (Cr) were presented. The numerical model was well validated with the available experimental results. The results indicated that the use of perforated twisted tape leads to a reduction in pressure drop and heat transfer rate, subsequently; a significant increase in TEF was seen compared to simple twisted tapes. In addition, some correlations were formulated to present the numerical results.
first_indexed 2024-12-23T11:48:31Z
format Article
id doaj.art-8837563a9bd140e9aed90b63c451412a
institution Directory Open Access Journal
issn 2214-157X
language English
last_indexed 2024-12-23T11:48:31Z
publishDate 2017-09-01
publisher Elsevier
record_format Article
series Case Studies in Thermal Engineering
spelling doaj.art-8837563a9bd140e9aed90b63c451412a2022-12-21T17:48:16ZengElsevierCase Studies in Thermal Engineering2214-157X2017-09-0110C16116810.1016/j.csite.2017.06.001Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchangerNemat MashoofiSaman PourahmadS.M. PesteeiThe main objective of this numerical study is to investigate the ways to reduce the pressure drop and consequently increase thermal performance enhancement factor (TEF) of a heat exchanger equipped with twisted tapes. For this purpose, axial perforated twisted tapes (PTTs) with various hole diameters are used instead of simple twisted tapes (STTs). Moreover, the variations of the effectiveness with number of transfer units (NTU) for different heat capacity ratios (Cr) were presented. The numerical model was well validated with the available experimental results. The results indicated that the use of perforated twisted tape leads to a reduction in pressure drop and heat transfer rate, subsequently; a significant increase in TEF was seen compared to simple twisted tapes. In addition, some correlations were formulated to present the numerical results.http://www.sciencedirect.com/science/article/pii/S2214157X17300758Double tube heat exchangerAxial perforated twisted tapeThermal performance enhancement factorEffectivenessFriction factorNumerical studies
spellingShingle Nemat Mashoofi
Saman Pourahmad
S.M. Pesteei
Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
Case Studies in Thermal Engineering
Double tube heat exchanger
Axial perforated twisted tape
Thermal performance enhancement factor
Effectiveness
Friction factor
Numerical studies
title Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
title_full Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
title_fullStr Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
title_full_unstemmed Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
title_short Study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
title_sort study the effect of axially perforated twisted tapes on the thermal performance enhancement factor of a double tube heat exchanger
topic Double tube heat exchanger
Axial perforated twisted tape
Thermal performance enhancement factor
Effectiveness
Friction factor
Numerical studies
url http://www.sciencedirect.com/science/article/pii/S2214157X17300758
work_keys_str_mv AT nematmashoofi studytheeffectofaxiallyperforatedtwistedtapesonthethermalperformanceenhancementfactorofadoubletubeheatexchanger
AT samanpourahmad studytheeffectofaxiallyperforatedtwistedtapesonthethermalperformanceenhancementfactorofadoubletubeheatexchanger
AT smpesteei studytheeffectofaxiallyperforatedtwistedtapesonthethermalperformanceenhancementfactorofadoubletubeheatexchanger