Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitator

The efficiency of an electrostatic precipitator (ESP) for reducing wood combustion emissions was investigated. Real-time measurements were conducted by directly reading the change in frequency of the tapered element in a Thermo Scientific 1400a TEOM. These measurements have been shown to be influenc...

Full description

Bibliographic Details
Main Authors: H. Burtscher, T. Nussbaumer, A. Lauber, N. K. Meyer
Format: Article
Language:English
Published: Copernicus Publications 2009-03-01
Series:Atmospheric Measurement Techniques
Online Access:http://www.atmos-meas-tech.net/2/81/2009/amt-2-81-2009.pdf
_version_ 1819037154265792512
author H. Burtscher
T. Nussbaumer
A. Lauber
N. K. Meyer
author_facet H. Burtscher
T. Nussbaumer
A. Lauber
N. K. Meyer
author_sort H. Burtscher
collection DOAJ
description The efficiency of an electrostatic precipitator (ESP) for reducing wood combustion emissions was investigated. Real-time measurements were conducted by directly reading the change in frequency of the tapered element in a Thermo Scientific 1400a TEOM. These measurements have been shown to be influenced by the charge on the aerosols reaching the tapered element such that the TEOM overestimates mass concentration. This electrostatic effect was crosschecked with particle mass concentration and particle number concentration measurements where no influence was observed. Placing a radioactive neutraliser prior to the TEOM leads to agreement between observed ESP efficiencies as measured by both the TEOM, mass filters and a CPC.
first_indexed 2024-12-21T08:16:54Z
format Article
id doaj.art-889e1b3fc3c844eca7731fcda9aa1fd2
institution Directory Open Access Journal
issn 1867-1381
1867-8548
language English
last_indexed 2024-12-21T08:16:54Z
publishDate 2009-03-01
publisher Copernicus Publications
record_format Article
series Atmospheric Measurement Techniques
spelling doaj.art-889e1b3fc3c844eca7731fcda9aa1fd22022-12-21T19:10:33ZengCopernicus PublicationsAtmospheric Measurement Techniques1867-13811867-85482009-03-01218185Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitatorH. BurtscherT. NussbaumerA. LauberN. K. MeyerThe efficiency of an electrostatic precipitator (ESP) for reducing wood combustion emissions was investigated. Real-time measurements were conducted by directly reading the change in frequency of the tapered element in a Thermo Scientific 1400a TEOM. These measurements have been shown to be influenced by the charge on the aerosols reaching the tapered element such that the TEOM overestimates mass concentration. This electrostatic effect was crosschecked with particle mass concentration and particle number concentration measurements where no influence was observed. Placing a radioactive neutraliser prior to the TEOM leads to agreement between observed ESP efficiencies as measured by both the TEOM, mass filters and a CPC.http://www.atmos-meas-tech.net/2/81/2009/amt-2-81-2009.pdf
spellingShingle H. Burtscher
T. Nussbaumer
A. Lauber
N. K. Meyer
Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitator
Atmospheric Measurement Techniques
title Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitator
title_full Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitator
title_fullStr Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitator
title_full_unstemmed Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitator
title_short Influence of particle charging on TEOM measurements in the presence of an electrostatic precipitator
title_sort influence of particle charging on teom measurements in the presence of an electrostatic precipitator
url http://www.atmos-meas-tech.net/2/81/2009/amt-2-81-2009.pdf
work_keys_str_mv AT hburtscher influenceofparticlechargingonteommeasurementsinthepresenceofanelectrostaticprecipitator
AT tnussbaumer influenceofparticlechargingonteommeasurementsinthepresenceofanelectrostaticprecipitator
AT alauber influenceofparticlechargingonteommeasurementsinthepresenceofanelectrostaticprecipitator
AT nkmeyer influenceofparticlechargingonteommeasurementsinthepresenceofanelectrostaticprecipitator