Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual marker

AIM:To compare the accuracy of Toric intraocular lens(IOL)alignment using the Verion image guided system and conventional manual marker. METHODS:Prospective randomized controlled study. A total of 56 eyes of 47 age-related cataract patients who underwent phacoemulsification combined with Toric IOL i...

Full description

Bibliographic Details
Main Authors: Ke Feng, Rui-He Chen, Yu-Jun Li
Format: Article
Language:English
Published: Press of International Journal of Ophthalmology (IJO PRESS) 2022-05-01
Series:Guoji Yanke Zazhi
Subjects:
Online Access:http://ies.ijo.cn/cn_publish/2022/5/202205036.pdf
_version_ 1818048903155548160
author Ke Feng
Rui-He Chen
Yu-Jun Li
author_facet Ke Feng
Rui-He Chen
Yu-Jun Li
author_sort Ke Feng
collection DOAJ
description AIM:To compare the accuracy of Toric intraocular lens(IOL)alignment using the Verion image guided system and conventional manual marker. METHODS:Prospective randomized controlled study. A total of 56 eyes of 47 age-related cataract patients who underwent phacoemulsification combined with Toric IOL implantation in our hospital from June 2016 to December 2019 were randomly divided into two groups:In the image-guided group, Verion navigation system collected anterior segmental images before surgery, and Toric target was set to 27 eyes in axial direction. In the marker group, Toric target was marked at 0° and 180° levels before surgery, and Toric target was marked in 29 eyes in axial direction according to the labeling ring. At 1h, 1wk, 1 and 3mo postoperatively, the anterior segment of patients with dilated pupil was photographed. Photoshop software was used to analyze the deviation between the actual axial direction and the target axial direction of the two groups, and the patients' naked eye visual acuity(UCDVA), best corrected visual acuity(BCDVA)and residual astigmatism were recorded. RESULTS: At 1h and 3mo postoperatively, the deviation between the actual axis and the target axis of IOL in the navigation group was less than that in the marker group(1.5°±1.8° vs 3.1°±2.1°; 1.9°±1.6° vs 3.3°±2.4°, all P<0.05). There was no difference in UCDVA(LogMAR)between the navigation group and the marker group(0.04±0.08 vs 0.06±0.07, P=0.338)and there was no difference in residual divergence(-0.39±0.32 vs -0.45±0.31D, P=0.491)between two groups at 3mo after operation.CONCLUSION:Verion digital marking and manual marking showed high accuracy in marking Toric IOL axial direction. Although the navigation group showed no advantage in UCDVA and residual astigmatism, the IOL misalignment in navigation group was significantly smaller than the marker group, and Toric IOL axial direction was implanted more accurately under Verion digital marking.
first_indexed 2024-12-10T10:29:04Z
format Article
id doaj.art-88ac396410f3402f8362fd4b9daf7f33
institution Directory Open Access Journal
issn 1672-5123
language English
last_indexed 2024-12-10T10:29:04Z
publishDate 2022-05-01
publisher Press of International Journal of Ophthalmology (IJO PRESS)
record_format Article
series Guoji Yanke Zazhi
spelling doaj.art-88ac396410f3402f8362fd4b9daf7f332022-12-22T01:52:38ZengPress of International Journal of Ophthalmology (IJO PRESS)Guoji Yanke Zazhi1672-51232022-05-0122587587910.3980/j.issn.1672-5123.2022.5.36202205036Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual markerKe Feng0Rui-He Chen1Yu-Jun Li2Department of Cataract, Zhengzhou Aier Eye Hospital, Zhengzhou 450005, Henan Province, ChinaDepartment of Cataract, Zhengzhou Aier Eye Hospital, Zhengzhou 450005, Henan Province, ChinaDepartment of Cataract, Zhengzhou Aier Eye Hospital, Zhengzhou 450005, Henan Province, ChinaAIM:To compare the accuracy of Toric intraocular lens(IOL)alignment using the Verion image guided system and conventional manual marker. METHODS:Prospective randomized controlled study. A total of 56 eyes of 47 age-related cataract patients who underwent phacoemulsification combined with Toric IOL implantation in our hospital from June 2016 to December 2019 were randomly divided into two groups:In the image-guided group, Verion navigation system collected anterior segmental images before surgery, and Toric target was set to 27 eyes in axial direction. In the marker group, Toric target was marked at 0° and 180° levels before surgery, and Toric target was marked in 29 eyes in axial direction according to the labeling ring. At 1h, 1wk, 1 and 3mo postoperatively, the anterior segment of patients with dilated pupil was photographed. Photoshop software was used to analyze the deviation between the actual axial direction and the target axial direction of the two groups, and the patients' naked eye visual acuity(UCDVA), best corrected visual acuity(BCDVA)and residual astigmatism were recorded. RESULTS: At 1h and 3mo postoperatively, the deviation between the actual axis and the target axis of IOL in the navigation group was less than that in the marker group(1.5°±1.8° vs 3.1°±2.1°; 1.9°±1.6° vs 3.3°±2.4°, all P<0.05). There was no difference in UCDVA(LogMAR)between the navigation group and the marker group(0.04±0.08 vs 0.06±0.07, P=0.338)and there was no difference in residual divergence(-0.39±0.32 vs -0.45±0.31D, P=0.491)between two groups at 3mo after operation.CONCLUSION:Verion digital marking and manual marking showed high accuracy in marking Toric IOL axial direction. Although the navigation group showed no advantage in UCDVA and residual astigmatism, the IOL misalignment in navigation group was significantly smaller than the marker group, and Toric IOL axial direction was implanted more accurately under Verion digital marking.http://ies.ijo.cn/cn_publish/2022/5/202205036.pdfveirion image guided systemaxis markingtoric intraocular lens(iol)cataractastigmatism
spellingShingle Ke Feng
Rui-He Chen
Yu-Jun Li
Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual marker
Guoji Yanke Zazhi
veirion image guided system
axis marking
toric intraocular lens(iol)
cataract
astigmatism
title Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual marker
title_full Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual marker
title_fullStr Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual marker
title_full_unstemmed Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual marker
title_short Comparison of Toric IOL alignment marking using Verion image guided system and conventional manual marker
title_sort comparison of toric iol alignment marking using verion image guided system and conventional manual marker
topic veirion image guided system
axis marking
toric intraocular lens(iol)
cataract
astigmatism
url http://ies.ijo.cn/cn_publish/2022/5/202205036.pdf
work_keys_str_mv AT kefeng comparisonoftoriciolalignmentmarkingusingverionimageguidedsystemandconventionalmanualmarker
AT ruihechen comparisonoftoriciolalignmentmarkingusingverionimageguidedsystemandconventionalmanualmarker
AT yujunli comparisonoftoriciolalignmentmarkingusingverionimageguidedsystemandconventionalmanualmarker